Honeywell Fire-Lite SD355 Photoelectric Addressable Smoke Detector
- Manufacturer: Fire-Lite Alarms by Honeywell
- Model Number / MPN: SD355
- Variant – Combo Detector: SD355T (adds fixed-temperature 135°F / 57°C heat sensor)
- Addressable Version: SD355A
-
Genuine OEM Surplus Stock
-
Worldwide Express Delivery
-
Risk-Free Purchase
-
Secure B2B Transactions
Fire-Lite SD355 Photoelectric Addressable Smoke Detector – Honeywell
The Fire-Lite SD355 is a two-wire, plug-in addressable photoelectric smoke detector that operates exclusively on Fire-Lite Addressable Fire Alarm Control Panels (FACPs) — specifically the MS-9200UDLS and MS-9600UDLS Signaling Line Circuit (SLC) loops. It communicates smoke-density data in analog format back to the panel, where the FACP’s onboard algorithm applies the alarm threshold decision rather than the detector itself.
Each unit occupies one of up to 99 address slots on the MS-9200 series or one of 318 slots (159 per loop) on the MS-9600 series, set via a rotary decade switch at commissioning. On marine vessels, the SD355 integrates into the ship’s central safety network, where the FACP is typically interfaced with bridge alarm management systems and, where fitted, the Honeywell Safety Manager or equivalent integrated platform management system (IPMS), enabling automated cross-zone suppression triggers and voyage data recorder (VDR) event logging.
Technical Specifications
| Parameter | Specification |
|---|---|
| Detection Method | Photoelectric (light-scattering, unipolar chamber) |
| Operating Voltage Range | 15 to 32 VDC |
| Standby Current | 300 µA @ 24 VDC (1 SLC poll every 5 seconds, LED blink enabled) |
| Maximum Alarm Current | 6.5 mA @ 24 VDC (LED latched ON) |
| Operating Temperature Range | 0°C to 49°C (32°F to 120°F) |
| SD355T Temperature Range | 0°C to 38°C (32°F to 100°F) |
| Fixed Heat Alarm (SD355T) | 135°F (57.2°C) |
| Operating Humidity | 10% to 93% RH, non-condensing |
| Air Velocity Tolerance | Up to 4,000 ft/min (20 m/sec) without false alarm |
| Factory Sensitivity Setting | 1.5% nominal obscuration per foot |
| Address Capacity | Up to 99 (MS-9200 series) / Up to 318, 159 per loop (MS-9600 series) |
| Wiring Configuration | 2-wire SLC loop (Class A or Class B) |
| LED Indicators | Dual LED — blinks on SLC poll; latches ON in alarm |
| Diameter (installed, B350LP base) | 6.1 in (15.5 cm) |
| Height (installed, B350LP base) | 2.1 in (5.33 cm) |
| Weight (detector only) | 3.6 oz (102 g) |
| Housing Flammability Rating | UL 94-V0 |
| Circuit Board Protection | Full conformal coating; RF and transient suppression built-in |
| Compatible FACPs | MS-9050UD, MS-9200UDLS, MS-9600UDLS |
| MPN | SD355 |
Marine & Industrial Applications
- Accommodation block corridors, cabins, and stairwells on merchant vessels and passenger ships
- ECR (Engine Control Room) and cargo control rooms where smoldering fire risk from electrical panels is high
- Pump rooms, switchboard rooms, and electrical cable trunks on tankers and bulk carriers
- Offshore platform accommodation modules and hazardous-area adjacent corridors (non-ATEX zones)
- Ship’s pantry, laundry, and workshop spaces where smoke from overheating equipment precedes open flame
- Ro-Ro car decks and cargo holds (when part of a multi-zone early detection strategy)
- Shore-based industrial facilities: warehouses, server rooms, and control buildings integrated into Honeywell FACP networks
- Retrofit upgrades on vessels with existing Fire-Lite MS-9200 or MS-9600 loop infrastructure
Maintenance Guide: Hidden Failure Mode
There is a failure mode in the SD355 that rarely appears in technical documentation but is well-known to ETOs who have serviced fire systems on vessels with high-speed diesel main engines or Z-drives: rotary decade switch fretting. The address is set by two small plastic rotary wheels — one for tens, one for units — that physically contact a PCB trace ring beneath them. On vessels where structural vibration is transmitted into the deckhead mounting surface (typically 12 Hz–80 Hz from propulsion machinery), these plastic wheels experience micro-oscillation against their contact traces. Over 12–24 months, this produces oxide debris at the contact interface — essentially fretting corrosion on a scale invisible to the naked eye.
The symptom is intermittent address dropout: the FACP logs a random “device not responding” trouble event at that address, which clears on the next poll cycle. Most engineers chase this as a wiring fault or SLC loop issue, replacing cables and isolators, before eventually tracing it to the detector head itself. The fix is simple: apply a single drop of low-viscosity non-conductive contact lubricant to the switch wheel contact face, reset the address, and re-test. On vibration-heavy installations, fit anti-vibration mounts to the base plate, or switch to the screw-set address variant if loop architecture permits.
Datasheet & Installation Manual
- Official Product Datasheet (PDF):
Download SD355 / SD355T Datasheet – Fire-Lite by Honeywell (Bass United Mirror)
- Installation & Operation Manual (PDF):
Download SD355 / SD355T / AD355 Installation Manual – Fire-Lite (Brooks Equipment Mirror)
- Manufacturer Product Page:
Honeywell Buildings – SD355 Series (Official Page)
30 DAYS RETURN POLICY
RETURNS ACCEPTED IN 30 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES & OTHER CHARGES. WE AS A SELLER DO NOT ACCEPT THE RETURN AND REFUND IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AND ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.