GE IS220UCSAH1A UCSA-H1A Rev H Stand-alone PLC Processor Module

The GE IS220UCSAH1A (UCSA-H1A Rev H) is a very advanced, stand-alone controller module that works with the GE Mark VIe distributed control system (DCS). This PLC processor module is what makes the control platform work. It runs complicated, site-specific application code and keeps track of all the I/O network (IONet) communications that go along with it.

Unlike traditional rack-mounted controllers, the UCSA form factor works on its own and doesn’t need a special backplane. It fits perfectly on a panel baseplate, which cuts down on the amount of hardware needed and gets rid of backplane-related single points of failure. The QNX® Neutrino® real-time operating system runs on a powerful microprocessor in the IS220UCSAH1A. This means that it can run control logic in a way that is always the same, which makes it an important tool for factories that need to be 100% reliable. It works great with the ControlST software suite for setting up, keeping an eye on, and fixing problems.

 

Model Details:

  • Manufacturer: General Electric (GE)
  • System Series: Mark VIe
  • Module Type: UCSA (Stand-Alone Controller)
  • Manufacturer Part Number (MPN): IS220UCSAH1A
  • Hardware Revision: Rev H
  • Alternative Part Numbers / Aliases: UCSA-H1A, IS220UCSAH1A-H

 

Technical Specifications:

Specification Parameter Engineering Data / Rating
Manufacturer General Electric (GE Vernova)
Model Number / MPN IS220UCSAH1A (Internal Board: IS200UCSAH1A)
Control Platform Mark VIe / Mark VIeS / EX2100e / LS2100e Static Starter
Functional Acronym UCSA (Embedded Controller Module)
Microprocessor Freescale PowerPC PowerQUICC II Pro (MPC8349) @ 667 MHz
System Memory (RAM) 256 MB DDR SDRAM
Storage / Non-Volatile Memory Compact Flash / On-board Flash Memory (OS & Application Code)
Operating System QNX® Neutrino Real-Time Operating System (RTOS)
Input Supply Voltage 18.0 VDC to 32.0 VDC (24 VDC Nominal, Class 2 Isolated)
Power Consumption 12.0 W to 12.5 W Typical (Maximum 15.0 W)
Ethernet Interfaces 2x Independent 10/100Base-TX RJ-45 Ports (IONet / UDH / CDH)
Auxiliary Interfaces 1x USB 2.0 Host/Client Port; 1x Serial Diagnostic Console Jack
Diagnostic Indicators (LEDs) Power, Boot, Online, Flash, DC, Diag, Link/Act (Per Port)
Cooling Mechanism Natural convection / Base conduction (Fanless chassis)
Operating Temperature Range 0°C to +65°C (+32°F to +149°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Operating Humidity 5% to 95% Relative Humidity, Non-Condensing
Cabinet Mounting Vertical base/panel mount with rear ground screw chassis points
Physical Dimensions (H x W x D) 168 mm x 170 mm x 55 mm (approx. 6.6 in x 6.7 in x 2.2 in)
Weight 1.00 kg (2.2 lbs) module only; 1.35 kg shipping envelope

GE IS220UCSAH1A Mark VIe turbine controller module securely packaged in a protective anti-static storage bag for safe industrial shipping. Front communication faceplate of the GE IS220UCSAH1A processor module detailing R, S, T IONet RJ45 ports, ENET connections, and diagnostic LED status indicators. GE IS220UCSAH1A Rev H Mark VIe Stand-alone PLC Processor Module rating label displaying exact part number, barcode, and ATEX hazardous location certifications.

Applications

  • Power Generation: Control systems for gas turbines, steam turbines, and hydro turbines that can handle a lot of work.
  • Oil and Gas: controlling compressor stations, keeping an eye on pipelines, and automating offshore platforms.
  • Managing wind turbine farms and integrating large-scale solar arrays into the grid are two examples of renewable energy.
  • Aluminum smelting, steel milling, and continuous chemical processing plants are all examples of process industries.
  • Plant-wide DCS: Upgrades and retrofits that replace old Mark V or Mark VI control systems.

 

Equipment Compatibility

  • Gas Turbine Platforms: GE Frame 5, Frame 6B, Frame 7E/EA, Frame 7F/FA, Frame 9E, Frame 9F, and LM series aeroderivative packages (LM2500, LM6000, LMS100).
  • Steam Turbine Control: GE D11, A10, and industrial back-pressure/condensing steam turbine retrofits.
  • Excitation & Drive Systems: EX2100e Static Excitation Systems, LS2100e Load Commutated Inverters (LCI).
  • Associated Mark VIe Hardware:
    • Terminal Base Boards: IS200STCI, IS200SRLY, IS200TTUR, IS200TRPA.
    • Distributed I/O Packs: IS220PAICH1A/2A (Analog), IS220PDIAH1A/1B (Discrete In), IS220PDOAH1A/1B (Discrete Out), IS220PTURH1A (Turbine Special), IS220PPROH1A (Emergency Trip Protection).
  • Engineering Tools: GE ToolboxST (version V04.03.18C or higher recommended) and WorkstationST.

 

From the Desk of a Lead Field Controls Engineer: Er. Mr. Zainali F. Bhojani

1) Verify Your Firmware Compatibility via ToolboxST First:

Before physically inserting the IS220UCSAH1A into an active cabinet, check your system runtime version in ToolboxST. The UCSAH1A requires a minimum baseline runtime build (typically ControlST V04.03+ or earlier baseline profiles). If you are replacing a failed controller in a TMR set (<R>, <S>, or <T>), ensure the firmware baseline on your donor/replacement module matches the running nodes down to the minor release letter before running an automated flash update over IONet.

2) Respect the Cooling Envelope:

The UCSAH1A is naturally convection-cooled. In offshore turbine cabins and shipboard machinery rooms, ambient cabinet temperatures can escalate rapidly. Maintain a strict clearance of at least 100 mm (4 inches) above and below the module cooling grills. If retrofitting into high-density cabinets, do not bundle wiring directly across the convective heat chimney fins.

3) Dedicated Isolated Grounding:

Ensure the controller module’s chassis frame is bonded to an isolated, low-impedance instrumentation ground (TE – Technical Earth), not standard structural ship frame ground or utility plant noisy dirty power. Ground loop offset potentials exceeding 1.0 V across the IONet shield can induce cyclic communication frame drops.

4) TMR Hot-Swap Protocol:

When replacing this unit under live conditions in an online TMR system, verify that the remaining two channels (<S> and <T>) are in full dual-synchronous control mode with zero diagnostic alarms. Never sever power to the replacement rack without first running an I/O freeze diagnostic in the engineering station.

 

Frequently Asked Questions

Can the IS220UCSAH1A be swapped while the plant is operating?

Yes, provided the system is configured in Dual or Triple Modular Redundant (TMR) architecture and the healthy controllers have taken full bumpless control of the running loops. In Simplex systems, power must be isolated prior to replacement.

What is the exact difference between the IS220UCSAH1A and the IS200UCSAH1A?

The IS220UCSAH1A represents the complete, fully encased embedded controller module, including the housing, front faceplate, connectors, and mounting brackets. The IS200UCSAH1A designates the bare internal populated printed circuit board assembly.

Is this controller suitable for functional safety trip loops (SIL-3)?

No. While the IS220UCSAH1A provides high reliability for turbine governing, sequencing, and control, it is not certified for IEC 61508 safety loops. Dedicated safety loops require the yellow-housed Mark VIeS functional safety controllers (e.g., IS420UCSCS2A).

What external power supply is needed to power this module?

The module requires a clean, regulated 18 VDC to 32 VDC power source (nominal 24 VDC) and draws approximately 12.0 to 12.5 Watts. In GE Mark VIe cabinets, this is typically sourced from an upstream IS200 or IS220 series low-voltage power distribution board.

What do the front panel diagnostic LEDs mean during an abnormal boot?

If the Boot LED remains solid without transitioning to the Online status LED within 90 seconds, the module is either experiencing a DHCP/IP network configuration hang on the IONet, or corrupt flash memory is preventing the QNX microkernel from initializing. Inspect diagnostic messages via the serial diagnostic console.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.