AKO 226.0121-100 Three-Way Temperature Regulator DN100 PN16
Condition: New
Country of Origin: Germany
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
AKO 226.0121-100 Three-Way Temperature Regulator (DN100 / 100mm)
The AKO 226.0121-100 is a three-way thermostatic temperature control valve engineered for closed-loop marine engine cooling and industrial thermal regulation. Built with a heavy-duty EN-GJL-250 (GG25) grey cast iron housing and DN100 (100mm) PN16 flanged connections, this unit stabilizes fluid temperatures without requiring external electrical power, compressed air, or hydraulic actuator lines.
The 226.0121 configuration incorporates an integrated emergency manual override mechanism. This mechanical override allows engine room watchkeepers to manually position the internal tubular slider using a DIN 911 offset hex key during a wax-element failure, satisfying classification society safety mandates for main propulsion and auxiliary power generation systems.
Model Details
- Manufacturer: AKO Regelungstechnik GmbH & Co. KG (Germany)
- Series: Type Series 226.0121 (Self-Actuated 3-Way Regulator with Manual Override)
- Primary MPN: 226.0121-100
- Nominal Diameter: DN 100 (100 mm / 4 inch)
- Internal Thermostat Cartridge Series: 237.0120-xxx (4-element configuration for DN100; temperature set-point suffix -xxx selected per circuit spec)
- Port Configuration: 3-Way Mixing or Diverting (Ports A, B, and C cast onto body)
AKO 226.0121-100 Technical Specifications
| Specification Parameter | Technical Value |
|---|---|
| Manufacturer | AKO Regelungstechnik GmbH & Co. KG |
| Manufacturer Part Number (MPN) | 226.0121-100 |
| Valve Design | Self-Actuated 3-Way Proportional Temperature Regulator with Manual Override |
| Nominal Diameter (DN) | DN 100 (100 mm) |
| Flange Connection Standard | EN 1092-2 Form B, PN 16 |
| Housing Material | Grey Cast Iron EN-GJL-250 (GG25) |
| Internal Trim & Seal Material | Stainless Steel (SS), Brass (Ms), NBR Seals |
| Flow Coefficient (Kvs) | 156.70 m³/h |
| Maximum Operating Pressure | 16 bar |
| Permissible Differential Pressure | Up to 16 bar |
| Maximum Operating Temperature | 120 °C (Max. continuous 25 °C above fully open temperature) |
| Internal Thermostat Element | 4 × Type 237.0120-xxx Wax Expansion Cartridges |
| Flange Outer Diameter (D) | 220 mm |
| Bolt Circle Diameter (K) | 180 mm |
| Flange Bolt Holes | 8 × Ø19 mm |
| Flange Thickness (b) | 24 mm |
| Face-to-Face / Center-to-Bottom Dimensions | 403 mm (L) / 217 mm (h) |
| Net Weight | 43.0 kg – 44.0 kg |
| Auxiliary Power Requirement | None (100% Mechanical Self-Actuated) |
Features
- Zero Auxiliary Energy Operation: Internal wax-filled thermal expansion cartridges (237.0120-xxx) sense medium temperature directly and convert thermal expansion into proportional valve stroke without electrical or pneumatic inputs.
- Classification-Compliant Manual Override: Equipped with a lockable adjusting screw and counter-nut assembly that mechanically opens cooling Port C and throttles bypass Port B if a thermal element fails.
- In-Line Top-Entry Serviceability: Internal stainless steel/brass trim and all four wax thermostat elements can be replaced on-site through the top bonnet without unbolting the DN100 flanges from the shipboard piping.
- Pressure-Balanced Tubular Slider: Internal balanced tubular slider design eliminates sensitivity to system line pressure fluctuations and allows installation in any spatial orientation (horizontal, vertical, or inverted).
Compatible Marine & Industrial Engines
- MAN Energy Solutions (MAN B&W / MAN Diesel & Turbo): Auxiliary gensets and four-stroke propulsion engines (e.g., L16/24, L21/31, L23/30H, L27/38, L28/32H, and 32/40 series cooling water and lube oil modules).
- Wärtsilä / Sulzer / MaK / Deutz / Bergen: Medium-speed marine diesel engines utilizing DN100 PN16 flanged central cooling, HT jacket water, and lubricating oil temperature regulation loops.
- Industrial CHP & Power Plants: Stationary gas and diesel cogeneration units, compressor cooling skids, and hydraulic oil heat-recovery manifolds.
Primary Applications
- High-Temperature (HT) engine jacket water temperature stabilization.
- Low-Temperature (LT) central freshwater cooling loops and charge air cooler circuits.
- Main and auxiliary engine lubricating oil thermal control (prevents oil over-cooling and viscosity spikes during cold starts).
- Waste heat recovery and freshwater generator (evaporator) feedwater temperature regulation.
- Marine hydraulic power pack and gearbox oil cooling circuits.
Frequently Asked Questions
What is the difference between the AKO 226.0120-100 and the AKO 226.0121-100?
Both models share the exact same DN100 PN16 cast iron body, internal trim, and 156.70 m³/h flow rating. The 226.0121-100 adds an integrated mechanical emergency manual override screw on the housing, whereas the 226.0120-100 is the standard automatic version without manual override. Marine classification societies typically mandate the 226.0121 override version for critical main and auxiliary engine cooling circuits.
Can the AKO 226.0121-100 be mounted vertically or upside down?
Yes. Because the internal tubular slider is pressure-balanced and actuated by enclosed wax-expansion cartridges rather than gravity-dependent floats, the valve can be installed in any orientation—horizontal, vertical, or inverted—without affecting temperature regulation accuracy.
How do I change the operating temperature set-point on the AKO 226.0121-100?
You cannot adjust the automatic operating set-point externally. To change the regulation temperature, relieve system pressure, unbolt the top bonnet, and swap the four internal 237.0120-xxx wax thermostat elements for a matched set calibrated to your required temperature band (ranging from 05–15 °C up to 102–113 °C).
Does the AKO 226.0121-100 require electrical wiring or instrument air?
No. The regulator is completely self-actuated. Thermal energy from the passing water or lubricating oil directly expands the internal wax cartridges, providing reliable proportional control even during a complete vessel blackout.
How do I operate the emergency manual override in case of thermostat failure?
Loosen the locking counter-nut on the override spindle and turn the adjusting screw clockwise using a DIN 911 offset hex key while monitoring your local loop thermometer. Turning the screw clockwise forces the tubular slider open toward cooler Port C while throttling bypass Port B. Once desired operating temperature is achieved, tighten the counter-nut to lock the position until replacement thermostat elements can be installed.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.