Sirena EX 0100 STL L Explosion-Proof Signal Beacon

Condition: New – Open Box

Description

Sirena EX 0100 STL L Explosion-Proof Visual Signaling Device (110VAC, 40W)

The Sirena EX 0100 STL L is a heavy duty explosion-proof visual signalling beacon, suitable for use in high-risk industrial, maritime and hazardous situations. This signaling device is designed for use in harsh structural environments and provides different visual signals to signify significant process changes, equipment changes, or hazardous conditions in locations where extremely flammable gas or dust combinations are present. It is based on an EEx de explosion-proof principle of protection combining a flameproof enclosure with an increased-safety terminal compartment separating the possible electrical arcing from the ambient atmosphere. The EX 0100 STL L is a heavy industry infrastructure design, with a 110VAC power supply line, and needs a 40W power envelope.

Sirena EX 0100 STL L explosion-proof industrial visual signaling beacon featuring a heavy-duty red aluminum base, a clear borosilicate glass outer dome protected by a stainless steel wire guard cage, and an internal red Fresnel lens. Technical nameplate of Sirena EX 0100 STL L explosion proof signaling device showing ATEX Ex II 2 GD EEx de IIC T6 IP66 markings, 110Vac 40W electrical rating, and CESI 05 ATEX 043 certification details on a red metal housing.

Model Details

  • Brand: Sirena
  • Model: EX 0100 STL L
  • Manufacturer Part Number (MPN): EX 0100 STL L – 110V
  • Equipment Classification Type: Explosion-Proof Visual Signaling Beacon

Part Number Cross-References:

  • Sirena EX 0100 STF (Xenon variant family reference)
  • SIR-96184 (Alternative series baseline indicator reference)
  • EX0100STLL110VAC

 

Technical Specifications: Sirena EX 0100 STL L

Specification Parameter Engineering Value / Rating Statement
Nominal Input Voltage 110V AC (Alternating Current)
Power Consumption 40 Watts (40W)
Current Frequency Compatibility 50 Hz / 60 Hz Single Phase
Explosion Protection Code Ex II 2 GD | EEx de IIC T6 IP66 T85°C
Hazardous Zones Suitability Zone 1, Zone 2 (Gas); Zone 21, Zone 22 (Dust)
Ingress Protection Rating IP66 (IEC 60529 Compliant)
Temperature Class Designation T6 Max Surface Temp (Gas <= 85°C) / T85°C (Dust Layer)
Enclosure Body Material Marine-grade, copper-free aluminum alloy casting
Optical Dome Assembly High impact, heavy-duty borosilicate glass shield
Cable Entry Allocations Dual M25 x 1.5 threaded structural entries for certified Ex glands
Internal Terminal Strip Allocation Screw clamp terminal blocks (Line, Neutral, Protective Earth) up to 2.5mm²
Operational Temperature Envelope -20°C minimum to +40°C maximum continuous
Duty Profile Rating Continuous Operation S1 Duty Cycle
External Hardware Fixing High tensile 316 grade stainless steel fasteners

Key Features

  1. Explosion-Proof Dual-Isolation Architecture: Designed according to EEx de IIC T6 classification, utilizing a flameproof chamber paired with an increased safety connection base for maximum ignition deterrence.
  2. Corrosion-Proof Marine Construction: Heavy, low-copper aluminum alloy housing finished with a chemical-resistant polyester powder coat paired with a thermal shock-resistant borosilicate glass outer dome.
  3. High-Output Visual Dispersion: Standard internal mechanical and physical light pathways ensure omnidirectional illumination output over 360 degrees, breaking through dense ambient industrial airborne debris or sea spray.
  4. Severe Environment Ingress Resistance: Sealed completely to a verified IP66 rating, preventing fluid entry under high-pressure spray, heavy seas, and dense particulate accumulation.
  5. Continuous Industrial Duty Cycle: Internal electrical ballasts and thermal dissipation pathways are engineered to tolerate uninterrupted continuous duty profiles within hazardous zone thresholds.

 

Industrial Applications

  • Offshore oil exploration rigs, drilling platforms, and production facilities.
  • Petrochemical refineries, crude storage terminal manifolds, and gas compression stations.
  • Marine vessel engine rooms, liquefied natural gas (LNG) carrier decks, and cargo holds.
  • Hazardous dry material handling plants, grain elevators, and pharmaceutical pulverization facilities.
  • Wastewater treatment digester areas and chemical processing plants with Zone 1, 2, 21, and 22 designations.

 

System Compatible

  • Control Relay Compatibility: Operates with 110VAC solid state relays, conventional mechanical contactors, or direct digital output modules of leading PLC systems (e.g. Siemens S7-1200/1500, Allen-Bradley ControlLogix, Schneider Modicon) equipped with isolation relays capable of handling inductive and resistive loads up to 40W.
  • Cable Gland Hardware Compatibility: Direct structural installation for M25 x 1.5 Ex d or Ex e double-compression brass or stainless steel cable glands for armoured (SWA) or unarmoured marine cables.
  • Mounting Integration: Flat surface structural base mounting using typical bolt configurations for bulkheads, structural steel beams or equipment frames.

 

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.