ABB ATS022 Automatic Transfer Switch Controller

  • Model Number: ATS022 (Order Code: 1SDA065524R1)

  • Product Series: ATS02x Family (Advanced Control Unit)

  • Manufacturer: ABB SACE (Low Voltage Products)

  • Type: Automatic Transfer Switch Controller

  • Mounting Options: Door-mounted or DIN-rail mounted

  • Operating Modes: Automatic/Manual/Test (Complete/Gen Set)

  • Communication: Modbus RS485 (optional 24-110 VDC auxiliary supply)

  • Rated Voltage Range: Up to 480 VAC (external VT for higher)

  • Frequency Support: 16 2/3, 50, 60, 400 Hz

  • Certifications: EN-IEC 50178, EN 50081-2, EN 50082-2, IEC 68-2 series

  • Operating Temperature: -20°C to +60°C

  • Dimensions (H x L x D): 96 x 144 x 170 mm

  • Degree of Protection: IP20

  • Genuine OEM Surplus Stock

  • Worldwide Express Delivery

  • Risk-Free Purchase

  • Secure B2B Transactions

Description

ABB ATS022 Automatic Transfer Switch Description:

The ABB ATS022 automatic transfer switch is a state-of-the-art controller that makes it easy to transition between normal and emergency power sources, making sure that key applications always have power. This high-tech gadget keeps an eye on voltage, frequency, phase balance, and imbalances on both lines (LN1 and LN2). It can automatically regulate up to three circuit breakers (CB1, CB2, and CB3) with delays that can be set for reliable operation. The ATS022 handles 2CBs, 3CBs NPL, Bus Tie, and generator applications up to 480 VAC. It has a graphic LCD display, Modbus RS485 connection, and doesn’t need any extra power (unless in special circumstances like 16 2/3 Hz systems).

It has IP20 protection, multi-function logic, and meets IEC/EN 60947 requirements, making it great for hospitals, data centers, industrial processes, and marine installations. It also has test modes, alarm logging, and remote integration for better power management.

 

ABB ATS022 Manual Guide

Download the manual datasheet PDF

 

Technical Specifications: ABB ATS022

Parameter Specification
Rated Voltage (Un) Max 480 VAC (configurable: 100V/57V to 480V/277V)
Frequency (fn) 16 2/3 Hz, 50 Hz, 60 Hz, 400 Hz
Phases Supported 1-phase, 3-phase +N, 3-phase (per line, configurable)
Auxiliary Supply Not required (24-110 VDC for Modbus or 16 2/3 Hz)
Monitoring Functions Voltage min/max, frequency min/max, phase loss, voltage/freq imbalance, sequence

 

Applications:

1) Emergency Power Systems: For hospitals, data centers, and telecom, they can transition from the main power source to the generator and start up automatically.

2) Dual Utility Lines: Switching between two transformers or utilities that aren’t a priority, making sure that the load stays on during outages

3) Bus-Tie Configurations: 3CB control for connecting sections in parallel when there are problems in commercial buildings and industrial plants

4) Non-Priority Load Management: In energy-efficient buildings, CB3 automatically disconnects and reconnects secondary loads (NPL).

5) UPS and Critical Infrastructure: powering UPS, operating rooms, airports, hotels, and procedures that need to keep going.

6) Marine and Offshore: Reliable backup on ships and platforms with built-in generators

7) HVAC and fire safety: service switching that meets international criteria.

Shipping and Delivery

30 DAYS RETURN POLICY

RETURNS ACCEPTED IN 30 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES & OTHER CHARGES. WE AS A SELLER DO NOT ACCEPT THE RETURN AND REFUND IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AND ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.