Pfeiffer Vacuum TMH 262 Turbomolecular Pump
Condition: New
Country of Origin: Germany
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Pfeiffer Vacuum TMH 262 Turbomolecular Pump (PN: PM P02 990 A)
The Pfeiffer Vacuum TMH 262 (Manufacturer Part Number: PM P02 990 A) is an oil-free, drag-stage-equipped turbomolecular high-vacuum pump engineered for continuous industrial, analytical, and marine-grade laboratory environments. Manufactured at Pfeiffer Vacuum’s D-35614 Asslar facility in Germany, the TMH 262 utilizes a hybrid rotor design combining classical turbomolecular blading with a Holweck drag stage. This architecture allows the pump to operate against significantly higher fore-vacuum backing pressures compared to standard turbopumps, enabling the use of smaller, dry diaphragm backing pumps.
The rotor assembly is supported by a maintenance-free permanent magnetic radial bearing on the high-vacuum side and a ceramic ball bearing with integrated oil-reservoir lubrication on the fore-vacuum side. This configuration eliminates hydrocarbon backstreaming into the process chamber while maintaining low vibration signatures critical for sensitive analytical instrumentation, shipboard mass spectrometers, and electron microscopy systems.
Model Details
- Manufacturer: Pfeiffer Vacuum GmbH (Berliner Straße 43, D-35614 Asslar, Germany)
- Series / Model: TMH 262 (Standard Drag-Stage Turbomolecular Pump)
- Manufacturer Part Number (MPN): PM P02 990 A
- Flange Configuration: DN 100 ISO-K (Standard PM P02 990 A variant; also produced in DN 100 CF-F under adjacent sub-variants)
- Cooling Method: Air-cooled (standard forced convection via optional radial cooler) or Water-cooled (via accessory cooling block)
- Mounting Orientation: Any orientation (0° to 180° vertical or horizontal)
Technical Specifications: Pfeiffer Vacuum TMH 262 (PM P02 990 A)
| Specification Parameter | Technical Value / Rating |
|---|---|
| Manufacturer | Pfeiffer Vacuum GmbH (D-35614 Asslar, Germany) |
| Model / Series | TMH 262 Turbomolecular Pump |
| Manufacturer Part Number (MPN) | PM P02 990 A |
| Inlet Flange (High Vacuum) | DN 100 ISO-K |
| Exhaust Flange (Fore-Vacuum) | DN 16 ISO-KF / G 1/4″ |
| Venting Port | G 1/8″ |
| Pumping Speed (N2 / He / H2) | 210 l/s (N2) | 220 l/s (He) | 190 l/s (H2) |
| Compression Ratio (N2 / He / H2) | > 1 x 1011 (N2) | 1 x 108 (He) | 1.5 x 106 (H2) |
| Ultimate Pressure | < 1 x 10-7 hPa (diaphragm backing) | < 1 x 10-10 hPa (rotary vane backing) |
| Max. Fore-Vacuum Pressure (N2) | 16 hPa |
| Nominal Rotational Speed | 60,000 rpm (1,000 Hz) |
| Run-Up Time | 110 seconds |
| Drive Voltage & Power | 24 V DC / 48 V DC (via TC 600) | 160 W Max / 45 W Idle |
| Compatible Controllers | Pfeiffer TC 600, TCP 350 |
| Cooling Method | Air-cooled (convection/fan) or Water-cooled (50 l/h, 15°C–25°C) |
| Mounting Orientation | Any orientation (0° to 180°) |
| Protection Class | IP 30 (IP 54 with sealed connectors) |
| Net Weight | 6.2 kg (13.67 lbs) |
Features
- Hybrid Holweck Drag Stage: Delivers a high compression ratio and tolerates backing pressures up to 16 hPa, reducing fore-pump size requirements.
- Oil-Free High Vacuum Side: Upper permanent magnetic bearing eliminates lubricant exposure to the vacuum chamber, ensuring hydrocarbon-free operation.
- All-Position Mounting Flexibility: Precision-balanced rotor and sealed ceramic lower bearing wick lubrication allow installation at any angle without oil migration.
- Integrated Drive Electronics Interface: Engineered for direct coupling with Pfeiffer TC 600 or TCP 350 electronic drive units via 15-pin/25-pin industrial Sub-D and M12 interconnects.
- Low Acoustic & Vibration Profile: Dynamic rotor balancing keeps residual vibration amplitudes below 0.01 µm, preventing interference with sensitive optical or mass-spectrometry sensors.
Electrical Pinout & Terminal Allocations (Motor & Sensor Interface)
- Pins 1, 2, 3: 3-Phase Brushless DC Motor Windings (U, V, W) – High-frequency variable voltage drive (up to 1,000 Hz).
- Pins 4, 5: Motor Thermistor / PTC Temperature Sensor (Over-temperature trip threshold at 90°C winding temp).
- Pins 6, 7, 8: Hall-Effect Rotor Position Sensors (Signals H1, H2, H3; +5 V DC supply and ground reference).
- Pin 9: Shield / Protective Earth (PE) Chassis Ground.
- Auxiliary Accessory Port (M12 / 4-Pin): 24 V DC output (max. 0.5 A) for driving a TCF 012/013 venting valve or cooling fan.
Compatible Electronic Drive Units & Controllers
- Pfeiffer TC 600: Top-mounted or remote electronic drive unit (PN: PM C01 690 / PM C01 700).
- Pfeiffer TCP 350: Rack-mount 19-inch controller for legacy systems (requires adapter cable PM 041 901-T).
- Pfeiffer DCU 002 / HPU 001: Display and handheld programming units for RS-485 parameter configuration.
Compatible Backing Pumps & Accessories
- Diaphragm Backing Pumps: Pfeiffer MVP 015-2, MVP 020-3, or MVP 040-2 (for dry, oil-free systems).
- Rotary Vane Backing Pumps: Pfeiffer Duo 2.5, Duo 5 M, or Duo 10 M.
- Inlet Splinter Shield: PN: PM 016 312 (Recommended to protect rotor blades from particulate ingress).
- Venting Valve: Pfeiffer TCF 012 (24 V DC, normally closed, G 1/8″).
- Air Cooling Unit: Pfeiffer Radial Fan Kit (PN: PM Z01 302).
Part Number Cross-References
- PM P02 990 A: TMH 262, DN 100 ISO-K, standard ceramic bearing, no integrated controller.
- PM P02 991 A: TMH 262, DN 100 CF-F (ConFlat flange variant).
- PM P02 990 B: TMH 262, corrosive-gas / purge-gas ready variant.
- TMU 262 (PM P02 995 A): Integrated controller variant (TMH 262 pre-mounted with TC 600).
Frequently Asked Questions
What is the difference between the Pfeiffer TMH 262 (PM P02 990 A) and the TMU 262?
The TMH 262 (PM P02 990 A) is the standalone turbomolecular pump head without an attached electronic drive unit, requiring an external or cable-connected controller such as the TC 600 or TCP 350. The TMU 262 is the identical pump assembly pre-configured at the factory with a top-mounted or side-mounted TC 600 electronic drive unit.
Can the Pfeiffer TMH 262 be mounted upside down or horizontally?
Yes. Because the TMH 262 utilizes a dry permanent magnetic radial bearing on the high-vacuum end and an enclosed, capillary-fed oil wick reservoir for the lower ceramic ball bearing, it can be mounted in any orientation from 0° (vertical inlet up) to 180° (inverted) without lubricant leakage into the vacuum chamber.
How often does the bearing oil reservoir need to be serviced on the TMH 262?
Under standard clean operating conditions and ambient temperatures below 35°C, the lower ceramic ball bearing oil reservoir should be replaced every 16,000 to 20,000 operating hours (approximately every 2 years of continuous duty). High thermal loads or frequent venting cycles shorten this interval.
Which flange hardware is required for the PM P02 990 A inlet?
Part number PM P02 990 A is equipped with a DN 100 ISO-K clamp flange. It requires a DN 100 ISO-K centering ring (with Viton/FKM or Buna-N O-ring) and standard claw clamps (minimum 4 to 6 clamps depending on structural load) to mate with the vacuum chamber port.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.