KELLER PR-23SX-ETR-Ei Intrinsically Safe Marine Pressure Sensor
Condition: New with COC
Country of Origin: Switzerland
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
KELLER PR-23SX-ETR-Ei Intrinsically Safe Pressure Sensor
The KELLER PR-23SX-ETR-Ei is a microprocessor-compensated piezoresistive pressure transmitter engineered specifically for hazardous zones and severe marine environments. Incorporating KELLER’s floating piezoresistive silicon sensing cell isolated behind a flush or recessed 316L stainless steel diaphragm, this unit eliminates mechanical hysteresis and thermal drift across wide operating envelopes.
The PR-23SX-ETR-Ei integrates a dual-output architecture: a standard two-wire 4–20 mA analog current loop combined with a half-duplex RS485 digital interface (KELLER Bus / Modbus RTU). The ETR configuration specifies an extended temperature range capability alongside enhanced transient protection, while the Ei suffix designates Intrinsic Safety certification (ATEX / IECEx) for direct installation in Zone 0, Zone 1, and Zone 2 explosive atmospheres—such as crude oil cargo tanks, inert gas systems, LNG fuel supply lines, and offshore pump rooms—when paired with an approved Zener barrier or galvanic isolator.
Model Details
- Full Model Designation: KELLER Series 23SX – PR-23SX-ETR-Ei
- Manufacturer Part Number (MPN): PR-23SX-ETR-Ei (Base Series Code: 23SX / Order Code varies by calibrated bar range and thread standard, e.g., 222305.XXXX)
- Sensing Principle: Piezoresistive silicon measuring cell, oil-filled, hermetically sealed
- Pressure Reference: PR = Vented Gauge (Relative Pressure; measures against atmospheric reference via vented cable/breather)
- Variant Suffixes:
- SX: High-accuracy digital compensation (16-bit internal DSP) with RS485 + 4–20 mA
- ETR: Extended Temperature Range compensation & reinforced EMI/RFI marine immunity
- Ei: Intrinsically Safe (Ex ia IIC T4/T5/T6)
Technical Specifications: KELLER PR-23SX-ETR-Ei
| Specification Parameter | Technical Value / Rating |
|---|---|
| Manufacturer / Brand | KELLER Pressure (KELLER AG für Druckmesstechnik) |
| Model / MPN | PR-23SX-ETR-Ei (Series 23SX) |
| Pressure Reference | Vented Gauge / Relative Pressure (PR) |
| Measuring Ranges | 0…1 bar to 0…1000 bar (15 psi to 15,000 psi) |
| Analog Output | 4…20 mA (2-wire current loop) |
| Digital Interface | RS485 Half-Duplex (KELLER Bus / Modbus RTU) |
| Supply Voltage | 8…28 VDC (Ex Entity Max Ui = 30 VDC) |
| Ex Entity Parameters | Ui ≤ 30 V, Ii ≤ 100 mA, Pi ≤ 0.75 W, Ci ≈ 0 nF, Li ≈ 0 μH |
| Accuracy (Linearity/Hyst./Rep.) | ±0.05% FS typical / ±0.1% FS maximum |
| Total Error Band (TEB) | ±0.1% FS within compensated temperature range |
| Compensated Temperature | -10 °C to +80 °C (ETR extended up to +100 °C) |
| Operating Temperature | -40 °C to +100 °C (Subject to Ex T4/T5/T6 rating) |
| Wetted Materials | Stainless Steel AISI 316L (DIN 1.4404), Viton® FKM / EPDM O-ring |
| Process Connections | G 1/4″ Male, G 1/2″ Male (EN 837), 1/4″ NPT Male |
| Electrical Connections | Binder 723 (5-pin), MIL-C-26482 (6-pin), M12x1, DIN 43650 |
| Ingress Protection | IP65 to IP68 (connector dependent) |
| Hazardous Area Approvals | ATEX II 1 G Ex ia IIC T6…T4 Ga / IECEx Ex ia IIC T6…T4 Ga |
Features
- Dual Analog & Digital Output: Simultaneous 4–20 mA two-wire loop output and RS485 digital interface allowing multi-drop bus networking (up to 128 transmitters) and zero-point/span recalibration without removing the sensor from the process line.
- All-Welded 316L Stainless Steel Construction: Wetted parts and housing machined from DIN 1.4404 (AISI 316L) stainless steel—with optional Hastelloy C-276 diaphragms—resisting pitting corrosion from seawater, sour crude, and ballast water.
- Sub-0.05% Total Error Band (TEB): Onboard microcontroller mathematically corrects non-linearity, hysteresis, and thermal shifts across the entire compensated temperature window rather than relying on passive resistor trimming.
- High EMC & Surge Immunity: Built-in transient voltage suppression complies with marine classification society requirements (DNV, Lloyd’s Register, ABS) for high-vibration engine rooms and cargo decks.
Applications
- Marine Cargo & Ballast Tank Monitoring: Continuous hydrostatic level and vapor pressure measurement on chemical tankers, crude carriers, and LNG/LPG vessels.
- Inert Gas Systems (IGS): Monitoring scrubber tower differential pressure, deck water seal pressure, and main inert gas header pressure in hazardous deck zones.
- Main & Auxiliary Engine Systems: Fuel oil rail pressure, lube oil gallery pressure, scavenge air pressure, and cooling water circuit monitoring.
- Offshore Oil & Gas Wellheads: Subsea manifold hydraulic control units (HPU), blowout preventer (BOP) accumulator banks, and separator skids.
- Hazardous Area Pump Rooms: Suction and discharge pressure monitoring on cargo stripping pumps and fire-fighting foam systems.
Compatibility
- Safety Barriers & Isolators: Pepperl+Fuchs KFD2-STC4-Ex1, Stahl 9160/13-11-11s, MTL5541 Galvanic Isolators.
- PLC & Marine Alarm Monitoring Systems (AMS): Kongsberg AutoChief / K-Chief 600, Wärtsilä NACOS Platinum, Siemens SIMATIC S7-1500 (ET 200SP Ex AI modules), ABB Ability System 800xA.
- Configuration Software & Converters: KELLER CCS30 (Control Center Series 30) via KELLER K-114A or K-104B USB-to-RS485 converters (must be used strictly in non-hazardous safe areas or via Ex-rated RS485 isolators).
Part Number Cross-References
- KELLER Series Equivalents: PAA-23SX-ETR-Ei (Absolute pressure version), PD-23SX-ETR-Ei (Differential pressure version), PR-23SY-Ei (Analog-only budget alternative without RS485).
- Functional Industrial Equivalents: Trafag NAT 8252 Ex, WIKA IS-3 (Intrinsically Safe Pressure Transmitter), Danfoss MBS 4201 / MBS 5100 (Marine Ex-approved series),BD Sensors DMP 331i.
Frequently Asked Questions
What do the suffixes “PR”, “23SX”, “ETR”, and “Ei” stand for on this KELLER sensor?
PR indicates a vented gauge (relative) pressure sensor measuring against ambient atmospheric pressure. 23SX identifies the microprocessor-compensated piezoresistive transmitter series featuring simultaneous 4–20 mA analog and RS485 digital outputs. ETR denotes Extended Temperature Range calibration and enhanced transient protection, while Ei confirms Intrinsic Safety certification (ATEX / IECEx Ex ia) for use in explosive gas atmospheres.
How do I recalibrate the zero point or pressure range on the PR-23SX-ETR-Ei?
Unlike analog transmitters with mechanical potentiometers, the PR-23SX-ETR-Ei is adjusted digitally via its RS485 interface (Pins A and B). Using KELLER’s CCS30 software and an RS485 converter in a safe area, engineers can rescale the 4–20 mA output span, tare the zero point, and read internal temperature diagnostics.
What is the difference between the PR-23SX-ETR-Ei and the PAA-23SX-ETR-Ei?
The PR-23SX-ETR-Ei measures relative gauge pressure (referenced to atmospheric pressure via a vent tube), making it ideal for tank level and system line pressures. The PAA-23SX-ETR-Ei is an absolute pressure transmitter referenced to a sealed internal vacuum, typically used for barometric compensation, condenser vacuum monitoring, or subsea depth measurement where atmospheric venting is impossible.
Does the PR-23SX-ETR-Ei require an external safety barrier if connected to a standard PLC?
Yes. To maintain its Intrinsic Safety rating in hazardous zones, the 4–20 mA loop must be powered through an approved Ex-certified galvanic isolator or Zener barrier located in the non-hazardous safe area (such as the engine control room or cargo control room). Connecting it directly to a non-Ex PLC power supply voids the hazardous area certification.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.