SOCOMEC Box Vertelis Vision 100 PTS Power Monitoring Controller (MPN: 48990505)
The SOCOMEC Box Vertelis Vision 100 PTS (MPN: 48990505) is a pre-wired, surface-mounted power monitoring and energy management enclosure engineered for rapid deployment in decentralized low-voltage distribution networks, marine auxiliary switchboards, and industrial sub-metering retrofits. Designed around the compact DIRIS / Countis multi-function metering architecture housed inside a rugged polycarbonate IP65 cabinet, this unit aggregates multi-circuit electrical parameters—including True RMS currents, phase-to-phase/phase-to-neutral voltages, active/reactive/apparent power, power factor, and total harmonic distortion (THD)—and transmits real-time telemetry to upstream PLC, SCADA, or shipboard Power Management Systems (PMS).
The 48990505 arrives as a complete turnkey field-mountable station. It integrates internal voltage sensing protection, a factory-terminated current transformer (CT) test/shorting block interface, and an isolated RS485 Modbus RTU communication bus, drastically reducing installation man-hours during dry-dock retrofits or live plant expansions.
Model Details
- Manufacturer: SOCOMEC (France)
- Series: Vertelis / Box Vision 100 PTS
- Manufacturer Part Number (MPN): 48990505
- Configuration Variant: PTS (Pre-wired Terminal System with integrated voltage protection and RS485 comms)
- Enclosure Mounting Type: Wall / Bulkhead Surface Mount (4-point external lug or internal corner-bore fixing)
- Condition: New
Technical Specifications: SOCOMEC Box Vertelis Vision 100 PTS (48990505)
| Specification Category | Technical Parameter |
|---|---|
| Manufacturer / Brand | SOCOMEC |
| Model Series | Box Vertelis Vision 100 PTS |
| Manufacturer Part Number (MPN) | 48990505 |
| Auxiliary Power Supply | 110 – 230 VAC (±15%), 50/60 Hz, < 5 VA |
| Supported Network Topologies | 1P+N, 2P, 3P, 3P+N (Balanced & Unbalanced) |
| Voltage Measurement Range | 50 – 300 VAC (Phase-Neutral) / 86 – 520 VAC (Phase-Phase) |
| Current Input Rating | /5 A or /1 A via external Current Transformers (Programmable 5 A to 10,000 A) |
| Measurement Accuracy | Active Energy Class 0.5S / Class 1 (IEC 61557-12); V & I ±0.2% |
| Communication Interface | RS485 2-Wire Half-Duplex, Modbus RTU (9600 – 38400 bps) |
| Digital Output | 1 x Opto-isolated Pulse / Alarm Output (27 VDC max, 27 mA max) |
| Ingress & Impact Protection | IP65 Enclosure / IK08 Impact Rating |
| Operating Temperature | -10 °C to +55 °C |
| Dimensions (H x W x D) | 220 mm x 165 mm x 105 mm |
| Standards Compliance | IEC 61557-12, IEC 62053-21/22, IEC 61010-1, EN 61326-1, CE, RoHS |
Features
- Pre-Engineered Turnkey Enclosure: Eliminates panel fabrication by housing the meter, fused voltage disconnects, and CT shorting blocks inside a factory-tested IP65 polycarbonate housing.
- Comprehensive Multi-Parameter Telemetry: Measures per-phase and total V, I, Hz, kW, kVAr, kVA, PF, import/export kWh, kVArh, and individual voltage/current harmonics up to the 31st order.
- Seamless SCADA & PMS Integration: Native RS485 Modbus RTU interface maps directly into SOCOMEC Vertelis software, shipboard IAS/PMS consoles, and third-party PLCs without protocol converters.
- Safe Online Maintenance Architecture: Integrated CT short-circuiting terminals and pull-out voltage fuses allow technicians to service or swap the metering core without de-energizing the main busbar.
- High-Visibility Local Diagnostics: Transparent, impact-resistant viewing window exposes the backlit multi-line LCD and tactile navigation keys for rapid local load balancing and phase-rotation checks.
Compatibility
- SOCOMEC Current Transformers: TCB, TCO, TCBR, and split-core TRB/TRC series (/5 A and /1 A secondary output CTs).
- SOCOMEC Rogowski & Flexible Sensors: Compatible via external SOCOMEC integrator modules (when configured for 1 A secondary input).
- SOCOMEC Communication Gateways: DIRIS G-series (G30, G40, G50, G60) Ethernet/Modbus-TCP gateways and DIRIS Digiware M-50/M-70 communication hubs.
- Energy Management Software: SOCOMEC Vertelis Suite, Webview embedded energy servers, and standard Modbus RTU OPC servers (Kepware, Siemens WinCC, Schneider EcoStruxure, Kongsberg K-Chief).
- Internal Metering Core Spare: Compatible with SOCOMEC DIRIS A10 / A14 series DIN-rail metering modules (firmware dependent).
Frequently Asked Questions
What does the “PTS” designation mean on the SOCOMEC 48990505?
PTS stands for Pre-wired Terminal System. Unlike bare enclosures, the 48990505 comes pre-assembled with internal voltage-sensing disconnect fuses, auxiliary supply fusing, and dedicated current transformer (CT) short-circuiting terminal blocks, allowing direct field connection without external protective hardware.
Can the SOCOMEC Box Vertelis Vision 100 PTS work with 1 A secondary current transformers?
Yes. While 5 A secondary CTs are the standard industrial default, the internal metering module allows software configuration of the CT secondary rating between /5 A and /1 A, with programmable primary ratings from 5 A up to 10,000 A.
Is the 48990505 suitable for 440 VAC 60 Hz marine power distribution systems?
Yes. The voltage measurement inputs are rated up to 520 VAC phase-to-phase and 45–65 Hz, making the unit directly compatible with standard 440 VAC / 60 Hz and 400 VAC / 50 Hz shipboard distribution boards without needing step-down potential transformers (PTs). Note that the auxiliary power supply accepts 110–230 VAC, so on a 3-wire 440 VAC marine IT/ungrounded system without a neutral, a small 440V/230V control transformer is required to feed terminals 1 and 2.
How do I connect multiple Box Vertelis Vision 100 PTS units to a single SCADA or PMS master?
You can daisy-chain up to 32 units on a single shielded twisted-pair RS485 bus using Modbus RTU. Assign each controller a unique Modbus Slave ID (1 to 247) via the front keypad, keep baud rate and parity identical across all nodes, and activate the 120 Ω termination resistor only on the final device on the line.
What happens if the auxiliary power supply fails during operation?
All cumulative energy counters (kWh, kVArh), CT ratio configurations, and Modbus communication settings are stored in non-volatile EEPROM memory. When auxiliary power is restored, the controller automatically resumes metering and communication with zero data loss.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.