Endress+Hauser RIA45-A1A1 Panel Meter with Control Unit (24–230V AC/DC)

The Endress+Hauser RIA45-A1A1 is a DIN-standard (96 × 48 mm) panel-mounted process display and control unit engineered to monitor, linearize, and switch analog process signals in marine engine rooms, ballast control consoles, and industrial automation cabinets. Powered by a wide-range 24–230 V AC/DC power supply, the RIA45-A1A1 eliminates the need for external power adapters during retrofits across mixed-voltage shipboard panels.

The RIA45-A1A1 integrates a short-circuit-proof 24 V DC transmitter loop power supply (up to 250 mA), allowing direct powering of 2-wire pressure, level, temperature, or flow transmitters. The -A1A1 configuration provides one universal analog input, two SPDT changeover relay outputs for high/low limit switching or pump control, and one galvanically isolated analog output for signal retransmission to a shipboard Alarm Monitoring System (AMS) or PLC.

 

Model Details

  • Model Number: RIA45-A1A1
  • Manufacturer Part Number (MPN): RIA45-A1A1
  • Series: Endress+Hauser RIA45 Process Display
  • Order Code Decoding:
    • RIA45: Panel-mounted process display (96 × 48 mm)
    • A: Approval — Non-hazardous area (Safe Area)
    • 1: Power Supply — 24 to 230 V AC/DC (-20% / +10%), 50/60 Hz
    • A: Input — 1 × Universal Analog Input (Current, Voltage, RTD, Thermocouple, Resistance)
    • 1: Output — 2 × Relays (SPDT) + 1 × Analog Output (0/4–20 mA, 0–10 V) + 24 V DC Loop Power Supply

 

Features

  1. Wide-Range 24–230 V AC/DC Power Supply: Operates directly on 24 V DC shipboard emergency battery banks or 110/230 V AC main switchboard feeds without hardware jumpers or external transformers.
  2. Integrated 250 mA Loop Power Supply: Eliminates external DIN-rail power supplies by powering 2-wire 4–20 mA level, pressure, and temperature transmitters directly from the rear terminals.
  3. Multicolor Alarm Backlight: Automatically switches the LCD backlight from white/green to red when a programmed high or low limit relay trips, giving watchkeeping engineers instant visual fault recognition.
  4. 32-Point Tank Linearization: Converts nonlinear level signals from cylindrical, spherical, or irregular shipboard fuel oil and ballast tanks directly into volume (m³ or liters).
  5. IP65 Front Bezel & Pluggable Terminals: Sealed front housing resists engine room oil mist and washdowns, while removable rear terminal blocks allow 5-minute unit replacement during port stays.

 

Technical Specifications

Specification Parameter Technical Value
Manufacturer Endress+Hauser
Model / MPN RIA45-A1A1
Power Supply 24–230 V AC/DC (-20% / +10%), 50/60 Hz
Power Consumption Max. 22.5 VA / 10 W
Input Channels 1 × Universal Input (0/4–20 mA, 0–10 V, Pt100/500/1000, Cu100, TC J/K/T/N/B/S/R/L/U, 30–3000 Ohm)
Transmitter Loop Power 24 V DC (+15% / -5%), max. 250 mA, short-circuit proof
Relay Outputs 2 × SPDT Changeover Contacts (250 V AC / 3 A; 30 V DC / 3 A)
Analog Output 1 × Galvanically Isolated (0/4–20 mA, max. 500 Ohm; 0–10 V, min. 10 kOhm)
Display Type 5-digit 7-segment LCD (17 mm), multicolor backlight (white/green/red), bargraph
Linearization 32-point programmable linearization table
Panel Cutout 92 (+0.8) × 45 (+0.6) mm (DIN 43700)
Housing Dimensions 96 × 48 × 120 mm (W × H × D)
Ingress Protection Front: IP65 (NEMA 4X) / Rear: IP20
Operating Temperature -20 °C to +60 °C (-4 °F to +140 °F)
Certifications CE, cULus (UL 61010-1), RoHS, EAC, GL/DNV-GL Marine Series

Applications

  • Marine Engine Room Panels: Local display and high/low alarm switching for lube oil pressure, jacket cooling water temperature, and scavenge air pressure.
  • Fuel Oil & Ballast Tank Gauging: Linearized volume readout and pump start/stop control using 2-wire hydrostatic level transmitters.
  • Boiler & Steam Systems: Drum level indication, feedwater pressure monitoring, and automatic safety interlock tripping via SPDT relays.
  • Oily Water Separator (OWS) & Bilge Monitoring: Analog signal retransmission to the central AMS alongside local high-bilge relay alarms.
  • Industrial Process Skids: Skid-mounted chemical dosing, water treatment, and HVAC pump control panels.

 

Compatibility

  • Endress+Hauser Transmitters: Cerabar (PMP/PMC), Deltabar (PMD), Waterpilot (FMX167/FMX21), Micropilot (FMR), Prosonic (FMU), and iTEMP (TMT) series.
  • Third-Party Sensors: Any standard 4–20 mA, 0–10 V, Pt100/Pt1000 RTD, or Type K/J thermocouple from Danfoss, WIKA, Vega, Rosemount, or Kongsberg.
  • Control & Monitoring Systems: Retransmits isolated 4–20 mA / 0–10 V signals to Kongsberg K-Chief, Wärtsilä NACOS, Siemens S7 PLCs, and Allen-Bradley ControlLogix systems.
  • Configuration Software: Endress+Hauser FieldCare and ReadWin 2000 (requires E+H TXU10-AA or FXA291 USB-to-CDI interface cable).

 

Part Number Cross-References

  • Direct E+H Predecessor / Related Models: Endress+Hauser RIA250 (legacy predecessor — check cutout dimensions before retrofit), RIA45-A1A2 (with 2 relays + open collector), RIA45-A1C1 (dual universal input).
  • Functional Equivalents (Verify Cutout & Wiring): PR Electronics 5714D, Yokogawa UM33A, Red Lion PAX2A000.

 

Guide for Engine Room & Console Retrofits

  • Use the 32-Point Linearization for Day Tanks: When replacing mechanical float gauges on HFO or MGO service tanks with a 4–20 mA hydrostatic transmitter, load the vessel’s sounding table into the RIA45-A1A1 linearization curve. This gives the watchkeeper direct metric-ton or cubic-meter readouts without manual interpolation.
  • Program Relay Hysteresis: On shipboard bilge or cooling water systems subject to vessel rolling, set a deadband (hysteresis) of at least 3–5% and a switching delay of 3–5 seconds on Relays R1 and R2. This prevents relay chatter and premature contact welding.
  • Lock the Front Keypad: After commissioning, enable the 4-digit passcode lock in the Setup menu. Engine room vibrations and accidental bumps during panel cleaning can otherwise alter relay setpoints.
  • Retransmission Ground Loops: If you experience signal drift when feeding the RIA45’s analog output to an older AMS, verify that the shield is grounded at the AMS end only. The RIA45-A1A1’s analog output is galvanically isolated, which eliminates most ground-loop noise when wired properly.

 

Frequently Asked Questions

Can the Endress+Hauser RIA45-A1A1 power a 2-wire 4–20 mA transmitter directly?

Yes. The RIA45-A1A1 includes an integrated, short-circuit-proof 24 V DC loop power supply rated up to 250 mA, which is more than sufficient to power standard 2-wire pressure, level, or temperature transmitters without an external power supply.

What is the difference between the RIA45-A1A1 and the RIA45-A1C1?

The RIA45-A1A1 features one universal analog input channel, whereas the RIA45-A1C1 features two universal analog input channels for differential pressure, sum/average calculations, or dual-tank monitoring. Both share the 24–230 V AC/DC power supply and 2-relay output architecture.

Does the RIA45-A1A1 require software to configure, or can it be programmed from the front panel?

It can be fully programmed directly from the three front-panel pushbuttons without any software or cables. However, if you need to enter a 32-point tank linearization table or clone settings across multiple meters, using Endress+Hauser FieldCare or ReadWin 2000 via the front 3.5 mm CDI port is significantly faster.

Is the RIA45-A1A1 suitable for marine engine room control consoles?

Yes. Its IP65-rated front bezel protects against oil mist and moisture, its wide-range 24–230 V AC/DC power supply handles shipboard voltage fluctuations, and the RIA45 series is designed to meet marine vibration and EMC requirements.

Can I use the RIA45-A1A1 to replace an older Endress+Hauser RIA250?

Functionally, yes—the RIA45-A1A1 is the direct successor to the RIA250. Both fit the standard 92 × 45 mm DIN panel cutout, though you should verify the rear terminal pinout against the BA00297R manual during rewiring, as terminal numbering differs between generations.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.