Yokogawa ADMAG AXF250G Magnetic Flowmeter

Condition: New – Open Box

Live Support
  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

Yokogawa ADMAG AXF250G-PNAL1S-AA11-2NB Magnetic Flowmeter (250mm / 10-Inch, Style S1)

The Yokogawa ADMAG AXF250G-PNAL1S-AA11-2NB is a high-capacity 250 mm (10-inch) electromagnetic flowtube engineered for heavy-duty process piping, marine cooling, and ballast transfer systems. Built on Yokogawa’s field-proven ADMAG architecture, this Style S1 primary sensor operates via Faraday’s Law of induction, utilizing Yokogawa’s proprietary dual-frequency excitation method to deliver high zero-point stability and noise immunity in low-conductivity, slurry, or pulsating flow environments.

Equipped with an anti-adhesive Fluorocarbon PFA lining, non-replaceable JIS SUS316L electrodes, standard JIS SUS316 grounding rings, and an ANSI Class 150 wafer connection, this unit guarantees high chemical resistance, mechanical rigidity, and accurate volumetric metering in maritime and onshore utility plants.

 

Model Details:

  • Base Model (MPN): AXF250G-PNAL1S-AA11-2NB
  • Style: S1
  • AXF250: Nominal Bore: 250 mm (10.0 Inch)
  • G: General Purpose Use (Non-Explosionproof Enclosure)
  • P: Combined Use with Remote Converter (AXFA14 compatible signal generation)
  • N: Power Supply: None (Passive remote flowtube powered via converter excitation coil terminals)
  • A: Lining Material: Fluorocarbon PFA

 

Technical Details

Parameter Specification Details
Nominal Diameter 250 mm (10.0 Inch)
Excitation System Pulsed Dual-Frequency AC/DC (via AXFA14 Converter)
Process Connection Wafer Design, Fits ANSI / ASME B16.5 Class 150 Flanges
Lining Material Fluorocarbon PFA (Perfluoroalkoxy)
Electrode & Ring Material Electrodes: JIS SUS316L (1.4404) | Grounding Rings: JIS SUS316 (1.4401)
Measuring Range (Velocity) 0.1 to 10 m/s (0.33 to 33 ft/s)
Reference Accuracy ±0.35% of rate (standard); ±0.20% optional high-accuracy
Fluid Conductivity Minimum 1.0 µS/cm (at operating temperature)
Fluid Operating Temperature -10°C to +160°C (14°F to 320°F)
Ambient Temperature Limits -10°C to +60°C (14°F to 140°F)
Operating Pressure Limit Up to 1.0 MPa (10 bar / 145 psi) standard ANSI 150 rating
Ingress Protection IP66 / IP67 (IEC 60529), NEMA 4X equivalent
Cable Conduit Connection Two ANSI 1/2 NPT Female Ports (Excitation & Flow Signal)
Terminal Housing Material Low-copper Cast Aluminum Alloy with Polyurethane Enamel Finish
Terminal Allocations A, B (Signal Electrodes), C (Shield), EX1, EX2 (Excitation Coils), Ground

Features

  1. Dual-Frequency Excitation Architecture: Combines fast response of high-frequency excitation with the ultra-stable zero point of low-frequency excitation, suppressing fluid-generated slurry noise and flow turbulence.
  2. Fluorocarbon PFA Molded Liner: Chemically inert, mirror-finished PFA liner prevents biological fouling, mineral scaling, and scaling deposits while resisting vacuum collapse.
  3. Low-Conductivity Fluid Sensing: Engineered to measure conductive fluids down to 1 µS/cm when paired with the AXFA14 converter.
  4. ANSI Class 150 Wafer Compact Footprint: Reduces pipeline installation weight and face-to-face dimensions compared to full-flanged spool pieces, ideal for cramped shipboard machinery spaces.
  5. Electrode Adhesion Diagnostic Compatibility: Transmits internal electrode impedance data to the converter for early detection of insulating wall deposition and predictive cleaning alarms.

 

Converter Compatibility

  • Yokogawa AXFA14G: General-purpose remote field-mount converter (HART or BRAIN protocol).
  • Yokogawa AXFA14C: Hazardous area / explosion-proof remote converter.
  • Legacy Interfacing: Backwards compatible with select Yokogawa AM11 and AXFA11 converters when configured with specific calibration factors and zero-offset adjustments.

 

Cross-References Part Numbers

  • Yokogawa Suffix Code Variants: AXF250G-E…, AXF250G-D…, AXF250C-PNAL1S… (Explosion-proof alternative)
  • Successor Product Line: Yokogawa ADMAG TI AXG Series (Model: AXG250G-P… – Next-generation digital transmitter interface)
  • Direct Equivalents (10-inch ANSI 150 PFA/SS Magmeters):
  • Krohne OPTIFLUX 4000 / 4300 (Size DN250)
  • Endress+Hauser Promag 50W / 400 (DN250 10″ Wafer/Flange)
  • Emerson Rosemount 8705 / 8750W Series (10-Inch PFA/316L)

 

Frequently Asked Questions

Can the AXF250G-PNAL1S-AA11-2NB operate as a standalone unit without an external transmitter?

No. The P code indicates this is a passive remote flowtube sensor body. It does not contain an internal power supply, display, or analog current loop converter. It must be wired to a Yokogawa AXFA14 converter (or compatible AXF-series converter) using dedicated excitation and signal cables.

What is the purpose of the dual calibration factors (L and H) listed on the nameplate?

Yokogawa uses dual-frequency excitation. The calibration factor represents two calculated constants: Factor L (low-frequency excitation constant for baseline zero stability) and Factor H (high-frequency excitation constant for rapid flow response and slurry noise rejection). Both values must be entered into the paired AXFA14 converter upon initial commissioning.

Is this flowmeter suitable for vacuum service or high-temperature steam flushing?

The PFA liner is securely anchored to the metal flowtube body, providing resistance against negative pressures (vacuum) up to 130°C. However, standard steam blowdowns exceeding 160°C will damage the PFA liner and the electrode seals. Always isolate the flowmeter if high-temperature steam flushes are carried out in process piping.

How do I check if the sensing electrodes or coils are defective?

Isolate the unit and disconnect terminals at the flowtube box. Using an insulation tester (500V DC Megger), verify that the insulation resistance between the coil terminals (EX1, EX2) and the flowtube housing ground is >100 MΩ. Measure coil resistance across EX1 and EX2 with a digital multimeter (typically 30 to 100 Ω depending on size). Finally, verify that terminals A and B show open circuit to ground while the tube is dry.

Does the wafer design come with flange installation bolts and gaskets?

The unit includes standard JIS SUS316 grounding rings pre-fitted to the liner face. Flange studs, nuts, and additional external flange gaskets required for sandwiching the wafer body between ANSI Class 150 pipe flanges are supplied as separate piping hardware kits based on your pipe schedule and rating.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.