Endress+Hauser FMX 570 Silometer Mono-R1E Monorack

$3,275.00

Condition: New – Open Box

Country of Origin: Germany

1 in stock

Description

Endress+Hauser FMX 570 Silometer Mono-R1E Monorack

The Endress+Hauser FMX 570 Silometer Mono-R1E Monorack is a continuous-level transmitter configuration that is very accurate and works perfectly with capacitance probes and hydrostatic pressure sensors (e.g. Deltapilot S series). The rugged instrument is designed as a 19-inch plug-in card for easy insertion into a Monorack housing or Racksyst assembly rack. The instrument converts Pulse Frequency Modulated (PFM) data to stable, linear analogue outputs.

Whether your business is to monitor bulk solids in industrial silos or liquid levels in marine holding tanks, the FMX570 enables intrinsically safe, fail-safe operations. This machine offers advanced on-board diagnostics and easy push button programming with integrated LC display.

New old stock Endress and Hauser FMX 570 level transmitter card resting alongside its original factory cardboard packaging box showing product model stickers. Front faceplate view of Endress and Hauser FMX 570 Silometer level transmitter plug-in card showing the LCD screen and calibration push-buttons.

 

Technical Specifications

Parameter Technical Data Specifications
Manufacturer Endress+Hauser
Model Code / MPN FMX570-AOE11 / MONO-R1E
Input Signal 1-Channel, 2-wire PFM (Pulse Frequency Modulation)
Power Supply Voltage 20 V to 30 V DC
Analog Output Signals 0/4…20 mA (max. 500 Ω) and 0/2…10 V (min. 10 kΩ)
Relay Outputs 1 Potential-free SPDT changeover contact (De-energizes on fault/fail-safe)
Maximum Switching Capacity 100 V, 2.5 A, 250 VA (cos φ = 1)
Operating/Ambient Temp. -20°C to +70°C (Storage: -40°C to +85°C)
User Interface LCD Display with configuration push buttons
Volume Linearization Up to 30 points (Standard horizontal cylinder function pre-programmed)
Weight Approx. 320 g

 

Features and Benefits

  1. Intrinsic Safe Architecture: Suitable for installation in hazardous process settings with particular explosion-protection ratings for flammable dusts and gases.
  2. Smart Dry-Calibration: Full calibration for hydrostatic measurement methods can be done straight from the transmitter interface without filling or draining the process vessel.
  3. Integrated Multi-Point Linearization: Internal volume calculation matrices that properly handle asymmetrical tank geometries such as horizontal cylindrical tanks or containers with conical discharge bottoms.
  4. Advanced Self-Monitoring Fault Systems Continuously samples all internal signalling pipelines from sensor to analogue output matrix. Immediately throws dry-contact relay alerts if open-circuits or short-circuits occur.

 

Applications

  • Marine Vessel Tank Management: For monitoring ballast water, fuel oil storage, slop tanks and wastewater hold systems when used with hydrostatic transmitters.
  • Bulk Solids Silo Infrastructure: Level determination of industrial powders, grain elevators, aggregate blends, plastic pellets and dry cement ingredients.
  • Chemical & Petrochemical Processing Constant volume indexing in hazardous area mixing vessels, buffer tanks and settling containers.
  • Water and Wastewater Facilities – Pumping station wet wells, open atmospheric retention basins, sludge processing towers, chemical feed tanks.

 

Part Number Cross-References

  • Endress+Hauser Predecessor Models: PMX470, FMC480Z, FMC470Z
  • Alternate Industry Designations: Z923 080-fN830Cpu923 077GZ-65.11-8, Z-65.13-10701
  • Marine Parts Registry Ref: MK1711 / SKU-116658

 

Product Compatibility & Hardware Pairing

The FMX 570 Silometer acts as the centralized signal converter and controller. To construct a functional measuring loop, it must be paired with compatible field devices and accessories:

  • Hydrostatic Pressure Transmitters: Endress+Hauser Deltapilot S (incorporating internal electronics inserts FEB 17 or FEB 17 P).
  • Capacitance Level Probes: Endress+Hauser capacitive rod or rope probes (incorporating electronic inserts EC 37 Z or EC 47 Z).
  • Mounting Enclosures: Racksyst assembly racks or dedicated single-card Monorack housings with matching backplane terminal strips.

 

Lead Time & Shipping Info

Dispatch Speed: Standard stock items depart our distribution center within 24 to 48 hours.

Global Express Logistics: Shipped worldwide via DHL Express, FedEx Priority, or air-freight forwarders. Tracking documentation is issued instantly via automated dispatch email notifications.

 

Engineer’s Insight:

Onboard ships or within heavy manufacturing areas, the two most prominent failure mechanisms for analog level monitoring are induced electromagnetic noise on signal cables and sloshing/buildup within the storage tanks.

Because the FMX 570 converts field data into a high-frequency Pulse Frequency Modulated (PFM) signal, it naturally provides exceptional resistance to the radio frequency and electromagnetic interference common in engine spaces and pump rooms. However, the internal card electronics remain sensitive to power-supply harmonics. Always ensure your 24V DC feeding the Monorack chassis is clean, ideally isolated through a dedicated marine-grade power conditioner.

 

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.