Marioff HI-FOG SBA40-A3P-S38/30-10M Section Ball Valve | 0-3600 PSI
Condition: New – Open Box
Make an Offer
HI-FOG SBA40-A3P-S38/30-10M Water Mist Fire Protect Section Ball Valve 0-3600PSI
The Marioff HI-FOG SBA40-A3P-S38/30-10M (Stock Code: D06160) is a precise heavy duty section ball valve suitable for use in high pressure water mist fire protection systems. This valve is installed contextually in wet-pipe or dry-pipe networks and divides the overall maritime or industrial fire suppression networks into separate zones.
Under normal standby situations this section valve is in its regularly open condition. When the system is activated (either by sprinkler heat rupture or by manual activation), water rushes through the valve and the flow change is detected by an integral differential pressure switch (or flow monitor). The integrated switch instantly communicates back to the fire control panel with a 24VDC electrical signal indicating the particular fire zone that has been activated. This unit has an integrated test port to support local loop testing and a manual shut-off handle to isolate the device during maintenance.
Model Details:
- Manufacturer: Marioff Corporation Oy (Finland)
- Model Designation: SBA40-A3P-S38/30-10M (sometimes formatted as SBA 40-A3P-S38/30-10-M)
- Stock Code / MPN: D06160
- Design Type: Normally Open Section Ball Valve with Manual Shut-off
- Monitoring Accessory: Integrated Differential Pressure Switch (24VDC)
Technical Specifications: SBA40-A3P-S38/30-10M
| Parameter | Technical Specification Value |
|---|---|
| Body Material | Marine-Grade Heavy Brass / Stainless Steel Internal Accents |
| Nominal Working Pressure | 140 bar (2030 PSI) |
| Max. Test / Design Pressure | 210 bar (3045 PSI) / Full Structural Limit 0-3600 PSI |
| Electrical Rating (Diff. Switch) | 24 VDC Control Voltage |
| Inlet Connection | 38.0 mm O.D. (Water Inlet to DIN 2353 Cutting Ring) |
| Outlet Connection | 30.0 mm O.D. (Water Outlet to DIN 2353 Cutting Ring) |
| A-Dimension (Total Width) | 148 mm |
| B-Dimension (Inlet to Center) | 104 mm |
| C-Dimension (Height) | ~339 mm |
| D-Dimension (Inlet Centerline) | ~253 mm |
| Valve Function | Normally Open (NO) with 90° Manual Shut-Off |
| Suitable Media | Fresh Water (High Purity / Demineralized for Mist Systems) |
| Environmental Protection | IP65 Rated Housing for the Electrical Switch Interface |
What are its features?
- Asymmetrical Connection Sizing: Built with a 38.0 mm outer diameter (O.D.) inlet connection and a 30.0 mm O.D. outlet connection using standard DIN 2353 cutting ring fittings for leak-proof sealing under extreme vibrations.
- Integrated Zone Identification: Factory placed 24VDC differential pressure switch provides instant notification to the centralized maritime fire safety control board when the sprinkler discharges.
- Manual Override & Isolation: A physical 90 degree operating sector handle provides manual system isolation for field maintenance, repairs or zone changes.
- In-Line Test Port: Integral test valve connection allows personnel to safely connect a test hose and perform diagnostic tests on the system without causing downstream water to discharge.
Systems & Equipment Compatibility
Primary System: Marioff HI-FOG High-Pressure Water Mist Fire Extinguishing Systems (Wet Pipe, Deluge, and Pre-Action Configurations).
Compatible Machinery & Spares:
- Marioff HI-FOG Pump Units (SPU, MSPU, GPU)
- Marioff Fire Control Panels (OMC, FCP)
- Standard High-Pressure Stainless Steel Tubing (38mm and 30mm external diameter)
Applications
- Commercial Vessels: Bulk carriers, Ro-Ro ships, container vessels, and luxury cruise liners.
- Offshore Units: Fixed drilling rigs, FPSOs, and semi-submersibles.
- Machinery Spaces: Protection zones encompassing propulsion machinery, auxiliary diesel generators, and purifier rooms.
- Accommodation Areas: Public spaces, passenger corridors, and galley protection zones.
Maintenance Guiance from NDMarineTech:
- Preventive Exercise: High-pressure marine water mist lines can accumulate localized mineral scaling if the system water is not periodically flushed. Cycle the manual 90° handle once every quarter during routine safety inspections to clear any micro-sediments on the ball seats.
- Electrical Testing Safely: Use the dedicated 1/4″ test port with a test hose (D23050) to route discharge water to a drain bucket. This triggers the differential pressure switch and tests the control board connection without flooding your dry-pipe zones or machinery spaces with high-pressure mist.
- Switch Replacement: If the 24VDC electrical block fails, the pressure differential switch assembly can be unscrewed and replaced without draining down the whole pipe network, provided the manual valve is completely isolated.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.