Siemens Sentron VL160X 20A 3-Pole Circuit Breaker (3VL1702-1DD36-0AA0)
The Siemens VL160X (Part Number: 3VL1702-1DD36-0AA0) is a 3-pole Molded Case Circuit Breaker (MCCB) engineered for primary plant, line, and feeder system protection. Designed within the proven Sentron 3VL family, the VL160X frame delivers high interrupting capacity in an exceptionally compact footprint.
Rated for a nominal continuous current of 20 Amperes at a calibration baseline of 50°C, this unit incorporates a thermal-magnetic trip unit (TM, LI function) featuring an adjustable inverse-time thermal overload release and a fixed instantaneous magnetic trip release. Built with a standard “N” breaking capacity rating, it clears severe short-circuit currents up to 55 kA at 415 V AC (IEC 60947-2). Its ruggedized mechanical architecture, high vibration tolerance, and multi-voltage ratings make it a reliable choice for marine switchboards, motor control centers (MCC), sub-distribution panels, and offshore marine engineering plants.
Model Details
- Manufacturer: Siemens AG
- Product Range: Sentron 3VL
- Frame Classification: VL160X (Frame Size 3VL1)
- Manufacturer Part Number (MPN): 3VL1702-1DD36-0AA0
- Configuration: 3-Pole (3P / 3-Phase switching) Trip Unit Type: Thermal-Magnetic (TM) Release, LI (Overload & Instantaneous Short-Circuit)
- Connection Interface: Front-side metric screw-type box terminals
Technical Specifications
| Electrical / Mechanical Parameter | Specification & Rated Value |
|---|---|
| Rated Uninterrupted Current (In) | 20 A (at 50°C standard reference temperature) |
| Number of Poles | 3 Poles (3P) |
| Rated Operational Voltage (Ue) | 690 V AC (50/60 Hz), up to 500 V DC |
| Rated Insulation Voltage (Ui) | 800 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Overcurrent Trip Unit Technology | Thermal-Magnetic Release (Type TM, Protection function LI) |
| Thermal Overload Setting Range (Ir) | Adjustable: 16 A to 20 A (dial-selected) |
| Instantaneous Short-Circuit Release (Ii) | Fixed: 300 A (15 x In) |
| Ultimate Short-Circuit Breaking Capacity (Icu) | 240 V AC: 65 kA 415 V AC: 55 kA 440 V AC: 25 kA 500 V AC: 18 kA 690 V AC: 8 kA |
| Service Short-Circuit Breaking Capacity (Ics) | 240 V AC: 65 kA (100% Icu) 415 V AC: 55 kA (100% Icu) 500 V AC: 14 kA (75% Icu) 690 V AC: 4 kA (50% Icu) |
| Utilization Category / Switching Class | Category A / Performance Class N (Standard) |
| Terminal Allocation & Type | Front-side screw connections (M6 hardware, 2.5 mm² to 95 mm² cable/busbar) |
| Operating Temperature Range | 0°C to +70°C (derating above 50°C: 18.6A at 60°C, 17.2A at 70°C) |
| Ingress Protection Rating | IP20 (with standard phase barriers and terminal covers) |
| Dimensions (H x W x D) | 157.5 mm x 104.5 mm x 106.5 mm |
| Net Weight | Approx. 1.47 kg (3.24 lbs) |
Compatibility
- Switchgear & Switchboards: Siemens Sivacon S8, Sivacon 8PT, and custom marine emergency/main switchboard distribution cubicles.
- Control Panels: Compatible with standard 35 mm DIN-rail systems (using 3VL9100 adapter base) or direct baseplate mounting panels.
- Sub-Line Replacement: Direct dimensional equivalent for Siemens legacy C45/3VE MCCBs, fits standard 3VL draw-out carriage and plug-in bases.
- Marine Plant Lineups: Generator auxiliary feeds, engine room fan distribution boards, separator control stations, and ballast pump auxiliary lines.
Applications
- Marine & Offshore Systems: Emergency switchboard feeder circuits, navigation console power feeds, bow thruster control circuits, engine room ventilation systems, and oily-water separator distribution.
- Industrial Motor Control: Low-power pump lines, conveyor drives, compressor control feeds, and machine tools requiring motor branch protection up to 7.5 kW at 400 V AC.
- Commercial Power Distribution: Sub-panel mains, lighting control cabinets, HVAC air-handling units (AHU), and data center UPS distribution tiers.
- Generator Sets & Power Plants: Auxiliary local generation skids, black-start diesel generator battery charging circuits, and critical switchyard auxiliaries.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.