The UniOP ePAD06-0046 is a ruggedized graphic operator panel engineered by Exor for local plant and machinery monitoring, auxiliary marine switchboards, and compact industrial automation skids. Equipped with a high-contrast 120 × 32 pixel monochrome LCD, a customized tactile keypad matrix, and native multi-protocol serial connectivity, the ePAD06-0046 delivers dependable human-machine interaction in demanding operating environments.
Unlike commercial touchscreens susceptible to false triggers or moisture failure, the ePAD06 relies on an industrial membrane keypad featuring tactile feedback switches, dedicated navigation keys, and configurable function buttons with slide-in legend strips. Designed to operate from an isolated nominal 24 VDC bus, the terminal is sealed to an IP65 ingress rating on the front bezel, making it resilient against spray, dust, and continuous industrial vibrations.
Model Details
- Manufacturer: Exor International / UniOP
- Series: ePAD Compact Series
- Model Designation: ePAD06
- Manufacturer Part Number (MPN): ePAD06-0046
Features
- High-Readability Transflective Monochrome LCD: 120 × 32 resolution displaying up to 4 rows × 20 characters of text, scalable fonts, process variables, and dynamic bargraphs.
- Tactile Industrial Keyboard: Industrial membrane surface featuring user-programmable function keys, numeric data entry, system keys, and integrated LED status indicators.
- Universal PLC Protocol Support: Direct point-to-point communication with over 130 serial automation protocols, including Modbus RTU, Siemens MPI/PPI, Allen-Bradley DF1, and Omron Host Link.
- Heavy-Duty IP65 Front Bezel: Engineered for NEMA 4 / IP65 washdown front-panel integration with chemical-resistant polyester faceplates.
- Fieldbus & Network Expandability: Includes an auxiliary expansion bus compatible with optional snap-on communication modules (Profibus DP, DeviceNet, CANopen, and Industrial Ethernet).
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Display Technology | Monochrome Graphic STN LCD with Yellow-Green LED Backlight |
| Display Resolution | 120 × 32 pixels (Standard 4 rows × 20 columns layout) |
| Active Viewing Area | 70 mm × 21 mm (2.75″ × 0.82″) |
| Input Voltage (Nominal) | 24 VDC (Operating tolerance: 18 VDC to 30 VDC) |
| Current Consumption | 0.25 A maximum at 24 VDC (~6 W total draw) |
| Power Supply Protection | Internal PTC automatic resettable fuse, reverse polarity protection |
| User Application Memory | 512 KB Flash EPROM |
| Keypad Layout & Inputs | Tactile membrane keypad, customizable function keys, cursor/enter matrix |
| Status Annunciators | LED status indicators (System LEDs & user-configurable LEDs) |
| Primary Serial Port (PLC) | 1× DB15 female connector: RS-232, RS-422, RS-485 software selectable |
| Programming / Download Port | Point-to-point serial upload/download (fixed/configurable up to 9600 bps) |
| Auxiliary Expansion Port | Proprietary expansion bus for Profibus DP, Ethernet, Interbus, CANopen modules |
| Front Bezel Dimensions | 149 mm (W) × 109 mm (H) / 5.86″ × 4.29″ |
| Panel Cutout Dimensions | 136 mm (W) × 96 mm (H) / 5.35″ × 3.78″ |
| Mounting Depth | 53 mm (2.08″) without expansion module; 75 mm with optional module |
| Weight | Approx. 1.0 kg (2.2 lbs) |
| Operating Temperature | 0°C to +50°C (32°F to +122°F) |
| Storage Temperature | -20°C to +70°C (-4°F to +158°F) |
| Relative Humidity | 5% to 85% RH (Non-condensing) |
| Environmental Enclosure Rating | IP65 Front Panel (with gasket correctly torqued), IP20 Rear Chassis |
Compatibility
- Siemens: SIMATIC S7-200 (PPI), S7-300 / S7-400 (MPI via adapter or optional CP module), S5 Series (TTY/AS511 interface).
- Rockwell Automation / Allen-Bradley: SLC 500 (5/01, 5/02, 5/03, 5/04 via DF1 or DH485), MicroLogix 1000/1200/1400/1500, CompactLogix (DF1 serial).
- Schneider Electric / Modicon: Modbus RTU / ASCII (Master/Slave via RS-485 or RS-232), TSX Premium, Micro.
- Mitsubishi Electric: MELSEC FX Series (FX1N, FX2N, FX3U), A-Series, Q-Series.
- Omron: Sysmac C-Series, CS1, CJ1 via Host Link (RS-232C / RS-422).
- Marine Engine & Generator Controllers: Woodward, Deif, ComAp, Dungs, and standard Modbus engine monitoring interfaces.
Frequently Asked Questions
What is the primary difference between the ePAD06-0046 and the ePAD05-0046?
The ePAD05 features an internal battery-backed hardware Real-Time Clock (RTC), 16 KB recipe storage, and dual-driver concurrent communication. The ePAD06-0046 is a streamlined, cost-effective model designed for direct PLC control and monitoring without native internal RTC or recipe memory.
Can I replace an older ePAD04-0046 unit directly with an ePAD06-0046?
Yes. The mechanical panel cutout (136 mm × 96 mm), front bezel size (149 mm × 109 mm), and DB15 communication port pin assignments are identical, making the ePAD06-0046 a drop-in physical replacement for older legacy units.
Which software is used to program and upload projects to the ePAD06-0046?
The unit is configured using UniOP Designer software (Version 5 or Version 6). You can download project files via an RS-232 serial programming cable connected to the main DB15 port using a matching UniOP serial adapter cable (CA114 / CA232).
Does the ePAD06-0046 have a touchscreen?
No. The ePAD06 is specifically engineered with an industrial tactile membrane keyboard rather than a touchscreen. This mechanical button design provides positive tactile feedback and ensures error-free operation when working with gloves or in environments where grease, spray, and moisture make touchscreens unreliable.
What is the proper procedure if the display has power but won’t communicate with the PLC?
First, verify that the pin assignment matches the communication protocol (RS-232 vs. RS-422/RS-485). Second, confirm that the communication speed, parity, station address, and node numbering configured in UniOP Designer match the PLC’s hardware configuration exactly. Finally, check that the DC 0V common rail is bonded properly to prevent floating ground offsets on the communication lines.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.