Riken Keiki GD-A80D Gas Detector 52K0113903-23 (HW-6213/CH4 Suction Type)

The Riken Keiki GD-A80D (Instrument No. 52K0113903-23) is a suction-type combustible gas detector head engineered for continuous hazardous-area monitoring aboard ocean-going vessels, offshore rigs, and petrochemical facilities. Built on the GD-A80 flameproof platform with a factory-fitted suction chamber, this specific assembly houses the HW-6213/CH4 catalytic combustion sensor configured for methane CH4 detection across the 0–100% LEL range.

The GD-A80D operates as a direct-wired sensing head. It receives regulated low-voltage DC bridge excitation directly from a remote Riken Keiki indicator/alarm unit (such as the RM-5000 or RM-6000) located in a non-hazardous control room and returns an analog bridge voltage proportional to the sampled gas concentration.

 

Model Details

  • Manufacturer: RIKEN KEIKI CO., LTD. (Tokyo, Japan)
  • Base Model Series: GD-A80 Series (Suction Type: GD-A80D)
  • Manufacturer Part / Instrument Number (MPN): 52K0113903-23
  • Installed Sensor Element: HW-6213/CH4 (Catalytic Combustion / New Ceramic Catalytic)
  • Target Gas: Methane / Combustible Hydrocarbon Gases (0–100% LEL)
  • Sampling Method: External Suction / Sample-Draw (via attached suction chamber and external pump unit)

 

Compatibility

  • Multipoint Indicator / Alarm Units: Directly compatible with the Riken Keiki RM-5000 Series (including RS-10 / RM-5000 rack systems carrying matching system serial block 52K0113903) and RM-580 indicator units.
  • Single-Channel Monitors: Compatible with the Riken Keiki RM-6000 single-channel indicator/alarm unit.
  • Sample-Draw Pump Units: Designed to pair with the Riken Keiki RP-D58.AC explosion-proof suction pump unit (such as paired assembly 52K0113903-21) or marine aspirator sampling assemblies.
  • Replacement Sensors: Accepts genuine Riken Keiki HW-6213 / NC-6213 series catalytic combustion elements matched to the indicator bridge calibration.

 

Features

  1. Gas Group IIC Flameproof Protection: Certified to Ex d IIC T4 / Ex db IIC T4 Gb, allowing deployment in the strictest hazardous zones containing methane, hydrogen, or acetylene vapors.
  2. Factory-Configured Suction Chamber (GD-A80D): Enables remote sample-draw monitoring from inaccessible void spaces, cargo pump rooms, or ducting when paired with an external pump or aspirator.
  3. High-Stability HW-6213/CH4 Catalytic Element: Delivers fast, repeatable 0–100% LEL methane response with low zero drift across shipboard ambient fluctuations.
  4. Direct Indicator-Powered Architecture: Eliminates field-side local power supplies by drawing regulated 3.0 V or 5.0 V DC excitation straight from the RM-5000 or RM-6000 control rack.
  5. Compact Corrosion-Resistant Enclosure: Weighs approximately 1.0 kg with IP65/IP67-equivalent ingress protection and supports both bulkhead wall mounting and 2B (50A) stanchion pipe mounting.

 

Technical Specifications — Riken Keiki GD-A80D (52K0113903-23)

Specification Details
Manufacturer RIKEN KEIKI CO., LTD. (Japan)
Model GD-A80D (Suction Type Fixed Gas Detector Head)
Instrument / Part Number (MPN) 52K0113903-23
Sensor Element HW-6213/CH4 (Catalytic Combustion / New Ceramic)
Target Gas & Detection Range Methane (CH4), 0–100% LEL
Sampling Method Suction / Sample-Draw (via attached suction chamber & external pump)
Electrical Input Rating DC 3.0 V (430 mA) or DC 5.0 V (200 mA) supplied from indicator unit
System Power Supply (Panel Side) AC 100 V or DC 24 V ±10% (via RM-5000 / RM-6000 / RM-580 indicator)
Signal Output Direct analog bridge voltage proportional to gas concentration
Terminal Connections M4 screw crimped terminals for sensor bridge leads; dedicated external grounding terminal
Transmission Cable CVV / CVVS 1.25 mm² or 2.0 mm², 4-core (shielded recommended)
Cable Entry Thread G 3/4 (PF 3/4)
Explosion-Proof Rating Ex d IIC T4 (TIIS) / II 2 G Ex db IIC T4 Gb (ATEX CML 15ATEX1027) / Ex db IIC T4 Gb (IECEx)
Ingress Protection IP65 / IP67 equivalent
Certified Ambient Temperature -40°C to +53°C (Nameplate Ex rating)
Operating Temperature Range -20°C to +53°C (constant condition)
Operating Humidity 0 to 95% RH (non-condensing)
Mounting Wall mount or 2B (50A) pipe mount
Dimensions (W × H × D) Approx. 78 × 163 × 105 mm (excluding fixing brackets)
Weight Approx. 1.0 kg

Applications

  • LNG & LPG Carriers: Continuous methane leak monitoring in compressor rooms, cargo machinery spaces, and interbarrier/insulation spaces.
  • Oil & Chemical Tankers: Pump room bilge and manifold sample-draw hydrocarbon detection systems.
  • Offshore Platforms & FPSOs: Zone 1 process deck, mud pit, and turbine enclosure combustible gas monitoring.
  • Marine Dual-Fuel (DF) Engine Rooms: Gas valve unit (GVU) enclosures, double-walled fuel gas supply piping ducts, and ventilation exhaust trunks.
  • Petrochemical Plants & Refineries: Hazardous storage tank farms, solvent recovery units, and loading racks requiring suction-type sampling.

 

Frequently Asked Questions

What is the difference between the Riken Keiki GD-A80 and the GD-A80D?

The GD-A80 is a standard diffusion-type gas detector head that relies on ambient air movement across the sensor. The GD-A80D uses the exact same flameproof body but is equipped with a suction chamber, allowing an external pump or aspirator to actively draw gas samples from remote pipes, ducts, or pump room bilges.

Which gas does the 52K0113903-23 assembly detect?

Assembly 52K0113903-23 is factory-fitted with the HW-6213/CH4 catalytic combustion sensor element, calibrated specifically to detect methane in the 0–100% LEL range.

Does the Riken Keiki GD-A80D output a 4–20 mA signal?

No. The GD-A80D is a direct-connect passive bridge detector head, not a 4–20 mA transmitter. It receives 3.0 V DC or 5.0 V DC excitation from a dedicated Riken Keiki indicator/alarm unit (such as the RM-5000, RM-580, or RM-6000) and outputs a proportional analog bridge voltage back to the panel.

Can the GD-A80D (HW-6213/CH4) be used inside an inerted tank or nitrogen atmosphere?

No. Catalytic combustion sensors require ambient oxygen to oxidize the target combustible gas. Operating the HW-6213/CH4 in an inert gas atmosphere will result in false low or zero readings. For inert atmospheres, use the thermal conductivity variant (GD-A80DN).

What hazardous area certifications apply to the Riken Keiki GD-A80D?

The GD-A80D holds flameproof explosion-proof certifications including ATEX (II 2 G Ex db IIC T4 Gb, certificate CML 15ATEX1027), IECEx (Ex db IIC T4 Gb), and Japan Ex TIIS (Ex d IIC T4), making it suitable for Zone 1 and Zone 2 hazardous areas including Gas Group IIC environments.

How often should the HW-6213/CH4 sensor inside the GD-A80D be calibrated?

For marine safety and industrial compliance, zero and span calibration with certified methane test gas is recommended every 6 months, as well as immediately after any sensor replacement or exposure to high gas concentrations.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.