Alfa Laval EPC-400 FOPX Control Panel
Condition: New
Country of Origin: Sweden
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Alfa Laval EPC-400 FOPX Brand New Complete Control Panel (MPN: 31830-6149-1)
The Alfa Laval EPC-400 FOPX Complete Control Panel is an automation and process monitoring unit engineered specifically for Alfa Laval ALCAP marine heavy fuel oil (HFO) and distillate separation systems. Housed in a ruggedized, bulkhead-mountable IP65 steel enclosure, this complete control assembly governs the entire centrifugal separation lifecycle—including sequence startup, continuous water-transducer-monitored clarification, automated sludge discharge cycles, and controlled shutdowns.
This complete panel assembly includes the hinged dual-PCB control module (front logic/HMI board and rear ALCAP water-transducer monitoring board), the internal mounting chassis with XA field wiring terminal blocks, the step-down control transformer (T1), the EMI power line filter (Z1), and integrated overcurrent circuit protection. It also incorporates an onboard Proportional-Integral (PI) temperature controller capable of directly regulating Alfa Laval Heatpac electric heaters or modulating steam, hot water, and thermal oil control valves.
Model Details
- Manufacturer: Alfa Laval Marine & Power AB (Made in Sweden)
- Series / Model: EPC-400 (FOPX ALCAP Configuration)
- Primary Manufacturer Part Number (MPN): 31830-6149-1 / 3183061491
- Technical Manual / Book Reference: 1818053-02 (Control Unit) / 1810135-02 (FOPX Parameter List)
- Dimensional Drawing Reference: 1762575 Rev.11
Technical Specifications: Alfa Laval EPC-400 FOPX Complete Panel
| Parameter | Specification / Rating |
|---|---|
| Brand / Manufacturer | Alfa Laval Marine & Power AB (Sweden) |
| Model / Series | EPC-400 Control Unit (FOPX ALCAP Configuration) |
| Manufacturer Part Number (MPN) | 31830-6149-1 / 3183061491 |
| Cross-Reference Part Numbers | 31830-6149-2, 31830-6149-3, 31830-6228-1, 31830-6228-2, 31830-6228-3 |
| Control Module PCB Assembly | 31830-5010-4 (Front Logic/Display Board + Rear ALCAP Transducer Board) |
| FOPX Firmware PROMs | Front PROM: 31830-6210-1 | Rear PROM: 31830-6132-1 |
| Mains Supply Voltage | 48 V AC (+10% / -15%) via Starter Transformer (24 V / 48 V AC Internal Rails) |
| Supply Frequency | 50 Hz / 60 Hz (Programmable via Parameter P21; Default 50 Hz) |
| Power Consumption | Max. 110 VA (Normal Separation) | Max. 200 VA (Sludge Discharge Sequence) |
| Internal Transformer (T1) | 4900795-18 (21–48 V / 10–20–24 V Multi-Tap) |
| Fuses & Circuit Protection | Main Breaker F11: 3.0 A (4900860-26); F12/F13: 1.6 A Slow; F1: 2.5 A Slow; F2: 250 mA Slow; F3: 5 A Slow |
| Analog & Sensor Inputs | WT 200 Capacitive Water Transducer (20 V DC pulsed on XA:4–5), Pt100 RTDs (TT1/TT2), High/Low Oil Pressure Switches, Vibration Switch, Emergency Stop |
| Control Outputs | Relay outputs for MV1 Solenoid Valve Block, V1 Recirculation Changeover Valve, Motor Starter Stop, Heatpac/Steam Heater PI Control, Common Alarm |
| Temperature Controller | Integrated PI Controller (P-band: 10–500%, I-time: 0.1–10.0 min, Setpoint: 0–110 °C / 0–240 °F) |
| Compatible Separator Models | Alfa Laval FOPX 605, FOPX 609, FOPX 610, FOPX 611, FOPX 613, FOPX 614, FOPX 616 |
| Enclosure Protection Rating | IP65 (Dust-tight and water-jet resistant) |
| Maximum Ambient Temperature | 55 °C (131 °F) |
| Net Weight | 21 kg (46.3 lbs) |
| Technical Manual References | Manual: 1818053-02 | Parameter List: 1810135-02 | Dimensional Drawing: 1762575 Rev.11 |
Features
- Automated ALCAP Sequence & Water Transducer Logic: Continuously monitors capacitive water content via the rear PCB (2b), automatically triggering sludge discharge or drain valve actuation before water breaks through the clean oil outlet.
- Integrated PI Heater Control Loop: Features a built-in Proportional-Integral controller with configurable P-band (10–500%) and I-time (0.1–10.0 min) to drive Alfa Laval Heatpac electric heaters or pneumatic/electric modulating steam valves.
- Dual-Tier Parameter Architecture (C1 & C2): Separates daily operational parameters (C1: discharge intervals, temperature setpoints, HFO/DO mode) from protected installation and timer parameters (C2: 50/60 Hz frequency, heater type, Profibus node address).
- Hinged Dual-Board Modular Chassis: Mounts the front operator/relay PCB and rear ALCAP interface PCB on a two-screw hinged aluminum frame, swinging open to expose the XA terminal strip, T1 transformer, and Z1 power line filter for rapid troubleshooting.
- Comprehensive Front-Panel Mimic & Diagnostics: Combines a 5-digit LED process/alarm code display with dual mimic LED rows indicating active solenoid outputs and sensor alarm states (high/low oil pressure, discharge failure, temperature deviation, vibration, and emergency stop).
Compatible Equipment Models
- Alfa Laval FOPX 605 (11 L/min opening water requirement)
- Alfa Laval FOPX 609 (18 L/min opening water requirement)
- Alfa Laval FOPX 610 (18 L/min opening water requirement)
- Alfa Laval FOPX 611 (18 L/min opening water requirement)
- Alfa Laval FOPX 613 (18 L/min opening water requirement)
- Alfa Laval FOPX 614 (18 L/min opening water requirement)
- Alfa Laval FOPX 616 (18 L/min opening water requirement)
- Compatible Ancillary Equipment: Alfa Laval WT 200 Water Transducer, Alfa Laval Heatpac EHM/EHS Electric Heaters, Steam/Thermal Oil modulating control valves, and MV1 solenoid valve blocks.
Part Number Cross-References
- Complete FOPX Control Unit Variants: 31830-6149-1, 31830-6149-2, 31830-6149-3, 31830-6228-1, 31830-6228-2, 31830-6228-3
- Internal Control Module (Hinged Dual-PCB Assembly): 31830-5010-4 / 31830-5010-1 / 31830-5010-2
- FOPX Firmware PROM Chips: 31830-6210-1 (Front Board PROM), 31830-6132-1 (Rear Board PROM)
- Internal Power Transformer (T1): 4900795-18 (21–48 V / 10–20–24 V)
- Main Circuit Breaker (F11): 4900860-26 (3.0 A push-push)
- 3-Year Recommended Spare Parts Kit: 31830-5021-2 (Includes 5x20mm slow-acting fuses 4900850-21, rubber push-button extensions 4901008-02, and screw terminals 4901156-03)
Frequently Asked Questions
What is the difference between Alfa Laval part numbers 31830-6149-1 and 31830-5010-4?
Part number 31830-6149-1 (written without hyphens as 3183061491) identifies the complete IP65 wall-mounted EPC-400 FOPX control panel assembly, including the steel enclosure, XA terminal blocks, T1 transformer (4900795-18), Z1 EMI filter, and the hinged control module. Part number 31830-5010-4 refers solely to the internal hinged dual-PCB control module without the outer cabinet or power supply hardware.
Can this EPC-400 FOPX panel be used on LOPX or MFPX separators?
While the physical enclosure and power supply hardware are shared across the EPC-400 family, part number 31830-6149-1 is factory-fitted with FOPX-specific firmware PROMs (31830-6210-1 and 31830-6132-1) tailored for ALCAP fuel oil purifiers (FOPX 605 through FOPX 616). Using it on an LOPX (lubricating oil) or MFPX separator requires swapping the PROM chips and reconfiguring the C2 installation parameters to match the specific machine type.
Does the EPC-400 FOPX panel require a separate controller for the oil heater?
No. The EPC-400 features an integrated Proportional-Integral (PI) temperature controller built directly into its logic board. Depending on how installation parameter P38 is configured, it can directly switch an Alfa Laval Heatpac electric heater or output control signals to a modulating valve for steam, hot water, or thermal oil heating systems.
What input voltage does the Alfa Laval EPC-400 panel operate on?
The EPC-400 panel operates on a nominal 48 V AC (+10% / -15%, 50/60 Hz) control supply typically stepped down from the separator motor starter cabinet. Inside the EPC-400 enclosure, the T1 transformer (4900795-18) further distributes isolated 24 V AC (XA:5) and 48 V AC (XA:6) power rails for field solenoid valves and internal logic circuits.
How do I unlock installation parameters (C2) when commissioning a brand new EPC-400 panel?
Open the front door, turn the internal mode selector switch to the P (Programming) position so Pro flashes on the display, and press the upper parameter selection button until C2 2 appears. Use the lower value push-buttons to change the access code to C2 12, which unlocks installation parameters (such as parameter P21 for 50/60 Hz selection and P38 for heater type).
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.

