Carrier Micro-Link 2i Controller 12-00458-00

Condition: New – Open Box (Without Original Box)

Live Support
  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

Carrier Micro-Link 2i Microprocessor Controller Module (MPN: 12-00458-00)

The Carrier Transicold Micro-Link 2i (ML2i) Microprocessor Controller Module (Part Number: 12-00458-00) serves as the central command architecture for marine refrigerated container machinery. Designed to withstand harsh blue-water maritime environments, the 12-00458-00 processes continuous operational logic for compressor staging, electronic expansion valve positioning, digital suction modulation, condenser/evaporator fan speeds, defrost cycles, and USDA cold-treatment monitoring.

The module integrates the central processing unit (CPU), solid-state digital inputs/outputs, analog sensor signal conditioning, and Carrier’s proprietary DataCORDER memory module directly on an industrial conformally-coated circuit board. Encased in a ruggedized protective backplate assembly, the ML2i module directly replaces damaged or degraded legacy controller boards in Carrier ThinLINE, EliteLINE, and early Streamline series reefer units.

 

Model Details

  • Manufacturer: Carrier Transicold Division (Syracuse, NY, USA)
  • System Family: Micro-Link 2i (ML2i) with Integrated DataCORDER
  • Manufacturer Part Number (MPN): 12-00458-00
  • PCB Sub-Assembly Reference: CEAS430173-05 / CEAS430173-XX
  • Service Replacement Part Number: 12-00458-00SV
  • EU Ref / Distributor Alternate: AC12-55000

 

Technical Specifications

Parameter Specification Details
Main Control Voltage Input 18 VAC to 24 VAC, 50/60 Hz (Derived from internal step-down transformer)
Operating DC Logic Rails Regulated +5.0 VDC (Analog/Logic), +12.0 VDC (Auxiliary), isolated ground reference
Internal Battery Backup 7.2V rechargeable NiMH battery pack (powers DataCORDER real-time clock during transit shutoff)
Microprocessor Architecture 16-bit industrial high-reliability MCU running proprietary Carrier refrigerated container firmware
Temperature Sensor Inputs (Analog) Compatible with Carrier NTC/PTC thermistor probes: Return Air (RRS/RTS), Supply Air (SRS/STS), Ambient (AMBS), Evaporator Defrost (DTS), Compressor Discharge (CPDS)
Transducer Inputs 0.5 to 4.5 VDC ratiometric pressure transducers: Suction Pressure (SPT) and Discharge Pressure (DPT)
Digital Switched Outputs Pilot-duty triac/relay drivers for 24 VAC contactor coils: Compressor (MC), Condenser Fan (CF), Evaporator High/Low (EF), Defrost Heaters (HR), Solenoids
Valve Modulation Channels Dedicated stepper/pulse output logic for Suction Modulation Valve (SMV) control
Data Logger (DataCORDER) Non-volatile flash memory recording cargo temperatures, trip alarms, and 4-point USDA cold-treatment logging
Communication Interface Standard front optical interface / Serial RS-232 / 9-pin sub-D interrogator port via unit harness
Operating Temperature Range -40°C to +70°C (-40°F to +158°F) ambient operating conditions
Enclosure & Board Protection MIL-I-46058C military-grade polyolefin/silicone conformal coating against salt spray and condensation
Weight & Dimensions Approx. 1.85 kg (4.07 lbs); 310 mm × 240 mm × 75 mm

 

Compatibility

  • Carrier ThinLINE Series: 69NT40-511-XX, 69NT40-521-XX, 69NT40-531-XX, 69NT40-541-XX
  • Carrier EliteLINE Series: 69NT40-551-XX
  • Carrier Streamline Series: Select transitional versions with ML2/ML2i architecture
  • Compatible Display Panels: 12-00433-00, 12-00433-00SV, 12-00570-00 series displays
  • Direct Drop-in Replacement for Legacy Controllers: 12-00375-00, 12-00438-00, 12-00445-00, 12-00458-00SV

 

Features

  1. Precision Cargo Climate Regulation: Employs proven proportional-integral-derivative (PID) control loops capable of maintaining perishable chilled commodities within ±0.25°C (±0.45°F) of setpoint.
  2. Integrated DataCORDER Logging: High-capacity on-board memory stores non-volatile time-temperature trip histories, operational events, and USDA Cold Treatment verification logs without external modules.
  3. Pre-Trip Inspection (PTI) Automation: Features onboard firmware testing protocols (Full PTI & Short PTI) that systematically stress-test contactors, coils, heaters, transducers, and sensors via Code 00.
  4. Marine-Grade Environmental Protection: Multi-layer moisture-proof conformal coating shields microcircuits, resistors, and solder joints from marine salt air, corrosive vapors, and heavy condensation.
  5. Modular Plug-and-Play Swapping: Factory pre-pinned terminal blocks and polarized edge connectors permit rapid field replacement inside the control cabinet within 15 minutes.

 

Primary Applications

  • ISO Intermodal Refrigerated Sea Containers: Standard 20ft and 40ft High-Cube container refrigeration units operated on container ships, terminals, and barge carriers.
  • Cold Treatment (USDA) Regulated Transit: Fresh fruit, citrus, and perishables requiring certified multi-probe cold treatment compliance for international import quarantine.
  • Intermodal Rail and Road Reefer Logistics: Intermodal container chassis operations running off clip-on generator sets (gensets) or underslung generators.
  • On-Shore Marine Cold Storage Yards: Static refrigerated container storage depots, port quarantine facilities, and seafood/perishable processing plants.

 

Frequently Asked Questions

What are the symptoms of a failing Carrier 12-00458-00 controller module?

Symptoms include a completely dead display with verified 24 VAC input power, sporadic processor resets under load, random un-resettable alarm codes (such as AL51 or AL52 memory/EEPROM errors), inability to modulate the suction modulation valve (SMV), or terminal failure to pass automated PTI test cycles.

Can I replace an older Micro-Link 2 controller with this Micro-Link 2i module?

Yes. The 12-00458-00 Micro-Link 2i is backwards-compatible with older Micro-Link 2 applications in Carrier ThinLINE units. Terminal blocks match standard pin allocations. However, verify that the configuration code (Cd) settings are adjusted to reflect your specific compressor model and valve setup during installation.

Does this unit come pre-loaded with firmware?

Service modules come flashed with stable, release-level operating system firmware. However, model-specific parameters (such as container size, high-pressure cut-out limits, and defrost profiles) must be confirmed and set via the front keypad during commissioning using the functional parameter setup procedure.

How does the DataCORDER differ from the operational controller memory?

The DataCORDER operates as an independent sub-section within the 12-00458-00 module. It records continuous time-stamped temperature logs, sensor data, and tamper-evident records intended for quarantine authorities (USDA), vessel operators, and insurance adjusters, and remains operational via battery backup even when main unit power is disconnected.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.