NOHMI VZAW004-P Address Setting Device (Electronic SLC Programmer)

The NOHMI VZAW004-P Address Setting Device is a dedicated handheld electronic programmer engineered for commissioning, replacing, and maintaining addressable detectors and interface modules on Nohmi Bosai fire detection systems. Unlike legacy fire alarm hardware that relies on mechanical DIP switches or rotary dials—which frequently suffer from contact oxidation and vibration drift in marine engine rooms—Nohmi addressable field devices store their Signaling Line Circuit (SLC) addresses electronically in non-volatile memory.

This commissioning tool writes and verifies unique loop addresses directly into each smoke detector, heat detector, sounder base, and input/output module prior to connecting the unit to a live Fire Alarm Control Panel (FACP). It supports both 127-address and 255-address Nohmi-protocol SLC loop architectures across marine vessels, offshore platforms, and industrial facilities.

 

Model Details

  • Manufacturer: NOHMI BOSAI LTD. (Japan)
  • Model / MPN: VZAW004-P
  • OEM Catalog Designation / Equivalent: FZAW004-P (Nohmi Integlex Multicrest Series)
  • OEM Partner Part Number: 3610053 (Potter Electric Signal Company)
  • Equipment Type: Handheld Electronic Address Setting Unit / SLC Device Programmer
  • System Protocol: Nohmi Addressable Protocol (Non-DIP Electronic Addressing)

 

Technical Details

Parameter Specification
Manufacturer NOHMI BOSAI LTD.
Model / MPN VZAW004-P
OEM Reference / Cross-Reference FZAW004-P / Potter 3610053
Device Type Handheld Electronic Address Setting Device
Supported Protocol Nohmi Addressable SLC Protocol
Address Capacity per Loop 127 or 255 Addresses (Panel Dependent)
Target SLC Nominal Voltage 24.0 VDC (22.0 to 24.0 VDC Working Range)
Target SLC Wiring Styles NFPA Class A (Styles 6 and 7), Class B (Style 4), Class X
Terminal Allocation (Target Side) S+ (Signal Line Positive), S- (Signal Line Negative)
Multi-Address Module Behavior Base address programmed manually; sequential addresses auto-allocated
Programming Mode Off-loop standalone addressing prior to FACP connection
Condition Options New / Reconditioned / Surplus (Power-on verified)

 

Input/Output Ratings & Terminal Allocations

  • Target SLC Electrical Rating: Programs field devices rated for a 22.0 to 24.0 VDC Signaling Line Circuit (SLC) working voltage range (24.0 VDC nominal) with typical standby currents of 250 uA per device.
  • Terminal Allocations (Module Programming): Connects directly across the polarity-sensitive S+ (Signal Line Positive) and S- (Signal Line Negative) terminals on Nohmi addressable input/output modules.
  • Detector Head Programming: Interfaces via the compatible detector base contacts or dedicated programming socket to write the electronic address directly to the detector’s internal memory before twisting the head onto the field base.
  • Sequential Address Allocation: When programming multi-point modules such as the Dual Contact Module (FRRU004-DCM4) or multi-circuit slim modules (FRRJ001 series), the technician programs only the primary address (n). The module firmware automatically reserves consecutive addresses (n+1, etc.) on the loop.

 

Compatible Fire Alarm Control Panels (FACPs)

  • Nohmi Integlex Multicrest Series: N3060 (1–12 loops, up to 3,060 addresses), N765 (1–3 loops, up to 765 addresses), and Integlex S508.
  • Potter Electric (Nohmi Protocol Panels): AFC-50, AFC-100, AFC-1000 / AFC-1000E / AFC-1000V, ARC-100, AP-100, IPA-60, IPA-4000 / IPA-4000V, PFC-6030, and PFC-6075R.

 

Compatible Addressable Field Devices

  • Analog Detectors: FDKU033-D & FDKU033-D-X (Photoelectric Smoke), FDLU019-D-X (Fixed Temperature Heat), FDHU003-D-X (Combination Rate-of-Rise / Fixed Heat).
  • Detector Bases: FZBU005-ASB (Addressable Sounder Base), FZBU004-AB4, FZBU013-2Z, FZBU013-4Z, FZBU005-AIB (Isolator Base).
  • Addressable Modules (UL Series): FRRU004-MCM (Miniature Contact), FRRU004-SCM4 (Single Contact), FRRU004-DCM4 (Dual Contact), FRRU004-TRM4 (Twin Relay), FRRU004-MOM4 (Monitored Output), FRRU004-CIZM4 (Conventional Initiating Zone), FRRU004-AIM (Analog Input), FQIU004-SCI (Short Circuit Isolator).
  • Japan Standard Slim Modules: FRRJ001A-Y-S, FRRJ001-Y-4S, FRRJ001A-Y-SS, FRRJ001-Y-2SS, FRRJ001-Y-4SD, FRRJ001-Y-4F, FRRJ001-Y-16F.

 

Features

  1. Switchless Electronic Addressing: Eliminates mechanical rotary wheels and DIP switches, preventing address corruption caused by shipboard vibration, salt-air corrosion, or accidental contact shifts.
  2. Full Nohmi Protocol Coverage: Supports every Nohmi-protocol analog detector, sounder base, and SLC interface module across 127-point and 255-point loop configurations.
  3. Off-Loop Pre-Commissioning: Allows marine electricians and fire technicians to program and verify replacement detectors on the workshop bench before climbing ladders or entering machinery spaces.
  4. Multi-Address Module Support: Automatically handles base-address assignment for dual-contact and multi-circuit modules without manual offset calculations.
  5. Cross-Platform OEM Utility: Works identically with native Nohmi Integlex panels and Potter Electric fire panels operating on the Nohmi SLC protocol.

 

Applications

  • Marine vessel fire detection loop commissioning and dry-dock statutory survey preparation (SOLAS fire safety maintenance).
  • Offshore oil rig, FPSO, and accommodation barge addressable fire alarm servicing.
  • Rapid shipboard replacement of fouled or faulted photoelectric smoke and thermal detectors in engine rooms, pump rooms, and steering gear compartments.
  • Industrial plant, power station, and warehouse fire alarm loop expansion using Nohmi Integlex or Potter Nohmi-protocol control panels.
  • Marine automation workshop bench testing and pre-dispatch programming of spare fire detectors.

 

Frequently Asked Questions

What is the difference between NOHMI VZAW004-P and FZAW004-P?

In marine and industrial spare parts listings, VZAW004-P corresponds to Nohmi Bosai’s handheld electronic address setting unit cataloged as FZAW004-P (also distributed under Potter Electric part number 3610053). Both refer to the same handheld programming tool used to assign electronic SLC loop addresses to Nohmi-protocol detectors and modules. Always verify the physical nameplate and connector layout before ordering.

Can the NOHMI VZAW004-P program both smoke detectors and addressable I/O modules?

Yes. It programs Nohmi analog photoelectric smoke detectors, fixed-temperature and rate-of-rise heat detectors, addressable sounder bases, and SLC interface modules (including contact, relay, monitored output, and conventional zone modules) prior to loop installation.

Do Nohmi addressable detectors have DIP switches as a backup if I do not have this programmer?

No. Nohmi Integlex Multicrest and Nohmi-protocol addressable detectors and modules use purely electronic, switchless addressing. You must use a compatible handheld address setting device or the host control panel’s built-in addressing function to assign or change a device address.

How does the programmer handle dual-address modules like the FRRU004-DCM4?

When configuring a multi-address module, you only program the first (base) address using the address setting device. The module automatically assigns the next sequential address (n+1) internally when connected to the Signaling Line Circuit.

Can this address setting device be used on Potter Electric fire alarm panels?

Yes, provided the panel is operating with Nohmi-protocol field devices (such as the Potter AFC, ARC, AP, IPA, and PFC-6000 series). Note that Potter PAD-protocol devices use physical DIP switches instead and do not use this handheld programmer.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.