Schneider Electric METSEPM2230D EasyLogic PM2230

Condition: New

Country of Origin: India

Live Support
  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

Schneider Electric EasyLogic PM2230 Power & Energy Meter – METSEPM2230D (Firmware V02.04.01)

The Schneider Electric METSEPM2230D is a three-phase digital power and energy meter from the EasyLogic PM2200 series engineered for high-accuracy electrical sub-billing, switchboard monitoring, and harmonic diagnostics. Built inside a compact 96 mm × 96 mm DIN enclosure with a 128 × 128 pixel monochrome backlit LCD, this unit samples electrical waveforms at 64 samples per cycle to deliver Class 0.5S active energy precision per IEC 62053-22. It measures four-quadrant active, reactive, and apparent energy alongside total harmonic distortion (THD) and individual harmonics up to the 31st order. Integrated 2-wire RS485 Modbus RTU communication allows direct integration into marine Power Management Systems (PMS), vessel automation consoles, and industrial SCADA networks.

 

Model Details

  • Manufacturer: Schneider Electric
  • Series: EasyLogic™ PM2200 Series
  • Model Designation: EasyLogic PM2230
  • Manufacturer Part Number (MPN): METSEPM2230D
  • Firmware Revision: V02.04.01
  • Form Factor: 96 mm × 96 mm Flush Panel Mount (54 mm behind-panel depth)
  • Weight: 300 g

 

Features

  1. Revenue-Grade Metering Accuracy: Certified to IEC 62053-22 Class 0.5S for active energy (±0.5%) and IEC 62053-24 Class 1 for reactive energy (±1.0%) with four-quadrant bidirectional energy tracking.
  2. Isolated RS485 Modbus RTU Interface: Built-in 2-wire RS485 serial port with 2500 V galvanic isolation supporting selectable baud rates from 4800 bps to 38.4 kbps (even, odd, or no parity).
  3. Wide Universal Control & Measurement Ranges: Operates on 80–277 V AC (±10%) or 100–277 V DC (±10%) auxiliary control power while measuring direct line-to-line voltages up to 480 V AC (CAT III) and up to 999 kV via external Voltage Transformers (VTs).
  4. Modular Expansion & Data Logging: Supports optional plug-in I/O expansion modules (2 Digital Inputs / 2 Digital Outputs or 2 Analog Inputs / 2 Analog Outputs) alongside onboard real-time clock stamping, power logs, and 23 configurable alarms.

 

Terminal Allocations & Input/Output Ratings

  • Control Power Supply Terminals (L1 / +, L2 / -): Accepts 80–277 V AC ±10% (45–65 Hz, ≤ 8 VA burden) or 100–277 V DC ±10% (≤ 3.3 W burden) with a typical 50 ms ride-through time at 120/230 V AC and 125 V DC.
  • Voltage Measurement Inputs (V1, V2, V3, VN – Top 4-Position Screw Terminal Block): High-impedance inputs (> 5 MΩ) rated for 20–277 V AC phase-to-neutral and 35–480 V AC phase-to-phase (Measurement Category III up to 480 V; Category II up to 600 V) across 45–65 Hz.
  • Current Transformer (CT) Inputs (I1+, I1-, I2+, I2-, I3+, I3- – Bottom 6-Position Screw Terminal Block): Low-impedance inputs (≤ 0.3 mΩ) rated for nominal 1 A or 5 A secondary CTs with a continuous measurement range of 5 mA to 6000 mA.
  • RS485 Communication Port (D+, D-, 0V/Shield – Screw Terminal Block): 2-wire half-duplex Modbus RTU interface rated at 2500 V insulation.
  • Local Status & Pulse Outputs: Front-panel green LED indicates power and RS485 traffic; front-panel red optical pulse LED outputs 1 to 9,999,000 pulses/k_h (kWh, kVAh, kVARh) for field calibration. Base unit includes 2 internal pulse inputs and 0 built-in relay outputs unless fitted with a PM2000 add-on I/O module.

 

Technical Details

Parameter Technical Specification
Manufacturer Schneider Electric
Product Series & Model EasyLogic PM2200 Series — PM2230
Manufacturer Part Number (MPN) METSEPM2230D
Firmware Version V02.04.01
Active Energy Accuracy Class 0.5S per IEC 62053-22 (±0.5%)
Reactive Energy Accuracy Class 1 per IEC 62053-24 (±1.0%)
Harmonic Analysis Total Harmonic Distortion (THD I & THD U) and Individual Harmonics up to 31st Order (Class 5)
Sampling Rate 64 samples per cycle
Auxiliary Control Supply [Us] 80–277 V AC ±10% (45–65 Hz) / 100–277 V DC ±10%
Power Consumption (Burden) ≤ 8 VA at 277 V AC / ≤ 3.3 W at 277 V DC
Voltage Measurement Range 20–277 V AC (L-N) / 35–480 V AC (L-L) direct; 480–999,000 V AC via external VT
Voltage Input Impedance > 5 MΩ
Current Measurement Range [In] 1 A or 5 A nominal CT secondary; 5 mA to 6000 mA operating range
Current Input Impedance ≤ 0.3 mΩ
Network Frequency Range 50 Hz / 60 Hz nominal (45–65 Hz measurement range, ±0.05% accuracy)
Supported Wiring Topologies 13 schemes: 1P2W, 1P3W, 3P3W (2-CT / 3-CT), 3P4W (3-CT)
Communication Interface RS485 2-wire, Modbus RTU (4800, 9600, 19200, 38400 bps; Even/Odd/None; 2500 V isolation)
Display & Controls 128 × 128 pixel monochrome backlit LCD, 4 front navigation pushbuttons, password tamper lock
IP Protection Rating IP54 (Front bezel) / IP30 (Rear enclosure) per IEC 60529
Overvoltage & Measurement Category Category III up to 480 V L-L / Category II up to 600 V L-L; Electrical Insulation Class II
Operating & Storage Temperature Operating: -10°C to +60°C / Storage: -25°C to +70°C (5–95% RH non-condensing at 50°C)
Dimensions & Weight 96 mm (W) × 96 mm (H) × 54 mm (D); Panel Cutout: 92 mm × 92 mm; Weight: 300 g
Enclosure Material & Flammability Polycarbonate, UL 94 V-0 flame retardant

 

Compatibility

  • Compatible Wiring Systems: Supports 13 configurable electrical distribution schemes including single-phase 2-wire (1P2W), single-phase 3-wire (1P3W), three-phase 3-wire delta (3P3W with 2 or 3 CTs), and three-phase 4-wire wye (3P4W with 3 CTs).
  • Compatible Sensors & Expansion Modules: Works with standard 1 A or 5 A secondary Current Transformers (CTs), external Potential/Voltage Transformers (PTs/VTs) up to 999 kV, and EasyLogic PM2000 series plug-in I/O expansion cards (2DI/2DO or 2AI/2AO).
  • SCADA & PMS Integration: Compatible with Schneider Electric EcoStruxure Power Monitoring Expert (PME), EcoStruxure Power SCADA Operation, and third-party marine/industrial Modbus RTU PLCs (Siemens, WAGO, Allen-Bradley, Kongsberg, DEIF).

 

Part Number Cross-References:

  • METSEPM2230 (Standard global commercial reference for EasyLogic PM2230)
  • METSEPM2230D (Regional / distributor-packaged variant of EasyLogic PM2230 with identical electrical hardware)
  • METSEPM2220 (Lower-tier PM2200 model with Class 1.0 active energy accuracy and up to 15th harmonic)
  • METSEPM2130 (LED-display counterpart in the EasyLogic PM2100 series with identical Class 0.5S & 31st harmonic specs)

 

Frequently Asked Questions

What is the difference between Schneider Electric METSEPM2230 and METSEPM2230D?

Both METSEPM2230 and METSEPM2230D share identical electrical hardware, Class 0.5S active energy accuracy, 31st-order harmonic measurement, 128 × 128 pixel backlit LCD, and RS485 Modbus RTU communication. The D suffix designates the regional/distributor-packaged commercial reference (METSEPM2230D), making it a direct 1:1 drop-in replacement for METSEPM2230 in existing 92 mm × 92 mm panel cutouts.

Can the Schneider Electric METSEPM2230D work with both 1 A and 5 A Current Transformers?

Yes. The current measurement inputs on the METSEPM2230D are software-configurable via the front keypad or Modbus registers to accept either 1 A or 5 A nominal secondary CTs, accurately measuring currents from 5 mA up to 6 A continuous.

Does the METSEPM2230D require a separate auxiliary power supply?

Yes. The meter uses an independent auxiliary control supply (L1/L2) rated for 80–277 V AC (±10%) or 100–277 V DC (±10%). Separating the auxiliary supply from the voltage measurement terminals (V1, V2, V3, VN) ensures the LCD display and RS485 Modbus communication remain active during main busbar voltage dips or blackouts.

Is the EasyLogic PM2230 suitable for 3-phase 3-wire marine delta systems without a neutral?

Yes. The METSEPM2230D supports 13 wiring configurations, including 3-phase 3-wire (3P3W) ungrounded or resistance-grounded delta systems commonly found on vessels, using either a 2-CT (Aron connection) or 3-CT arrangement up to 480 V AC line-to-line direct (or higher via external Voltage Transformers).

How do I lock the configuration settings on the METSEPM2230D to prevent unauthorized changes?

The meter includes a built-in four-digit password tamper-protection lock accessible through the front-panel setup menu, preventing unauthorized changes to CT/VT ratios, wiring topology, Modbus address, or energy accumulation counters.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.