Williams Milton Roy P1000V400 V Series Metering Pump

Condition: New

Country of Origin: United States

Live Support
  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

Williams Milton Roy P1000V400 V Series Metering Pump with Relay and Controller

The Williams Milton Roy P1000V400 (configured assembly code CRP1000V400) is a pneumatically actuated dual-seal plunger metering pump engineered for continuous chemical injection in offshore, marine, and hazardous-area process environments. Driven by a 4.00-inch pneumatic motor cylinder coupled to a 1.000-inch plunger, this assembly includes an integrated MK XIIA Oscillamatic® pneumatic controller and a PO3-6S single-acting pilot-operated servo relay. Because the entire drive and control architecture operates on regulated compressed air or sweet natural gas rather than electric motors, the unit is inherently non-incendive and intrinsically safe for Class I, Division 1 / Zone 1 explosive atmospheres without explosion-proof electrical enclosures.

 

Model Details

  • Base Pump Model: P1000V400
  • Complete Assembly MPN: CRP1000V400 (C = Controller, R = Relay, P = Pump)
  • Plunger Diameter Code (1000): 1.000 in. (25.4 mm) nominal plunger bore
  • Wetted & Pneumatic Housing Code (V): 316 Stainless Steel wetted fluid end and 316 Stainless Steel pneumatic drive cylinder (replaces standard X anodized aluminum drive housing for harsh marine salt-spray and corrosive atmospheres)
  • Motor Cylinder Diameter Code (400): 4.00 in. (101.6 mm) pneumatic drive piston diameter (requires pilot relay due to >3.00 in. cylinder volume)
  • Included Relay MPN: PO3-6S (Single-Acting Pneumatic Servo Relay)
  • Included Controller Series: MK XIIA Oscillamatic® Pneumatic Pulse Controller

 

Technical Specifications: Williams Milton Roy P1000V400 (CRP1000V400)

Specification Parameter Rating / Technical Detail
Brand / Manufacturer Williams (Milton Roy)
Base Model Number P1000V400
Complete Assembly MPN CRP1000V400 (Includes MK XIIA Controller & PO3-6S Relay)
Pump Type Pneumatic Positive-Displacement Dual-Seal Plunger Metering Pump
Plunger Diameter 1.000 in. (25.4 mm)
Pneumatic Drive Cylinder Diameter 4.00 in. (101.6 mm)
Maximum Discharge Pressure (@ 150 PSIG Supply) 2,300 PSIG (158.6 BAR)
Maximum Discharge Pressure (@ 100 PSIG Supply) 1,520 PSIG (104.8 BAR)
Maximum Flow Rate (100% Stroke @ 45 SPM) 9.08 GPH (34.37 LPH)
Displacement per Stroke 12.7 cc / stroke
Stroke Rate Range 1 to 45 Strokes Per Minute (SPM)
Stroke Length Adjustment 0 to 1.00 in. (0–100% Continuous Micrometer Adjustment)
Flow Turndown Ratio 100:1
Metering Accuracy ±3% (API-675 Compliant)
Amplification Ratio 15.38:1
Controller Pilot Air/Gas Supply 35 PSIG (2.41 BAR) Regulated
Relay Main Air/Gas Supply 35 PSIG to 150 PSIG (2.41 to 10.3 BAR) Regulated
Air/Gas Consumption (@ 100 PSIG / 45 SPM) 3,584 SCF/Day (101 SCM/Day)
Air/Gas Consumption (@ 150 PSIG / 45 SPM) 5,250 SCF/Day (149 SCM/Day)
Discharge Check Valve Cracking Pressure 90 PSIG (6.2 BAR)
Suction Head Requirement Flooded Suction: 1 ft (0.3 m) min to 10 ft (3.0 m) max
Maximum Fluid Viscosity 4,500 SSU (960 cP)
Wetted & Pneumatic Cylinder Material 316 Stainless Steel with TFE Composite Bearings & Seats
Pneumatic Port Connections 1/4 in. FNPT Supply, Drive & Exhaust Ports

Compatibility

  • Direct Replacement & Series Interchangeability: Directly interchangeable with legacy Williams Milton Roy X-Series (CRP1000X400) units where upgrading from anodized aluminum to full 316 SS marine-grade pneumatic cylinders is required.
  • Compatible Controllers & Relays: Works natively with Williams MK X, MK XIIA (manual stroke rate), and MK XIIB (3–15 PSIG pneumatic signal) controllers, as well as PO3-6S single-acting pneumatic relays.
  • Compatible Auxiliary Skid Components: Engineered for integration with Williams Air/Gas Dryer-Filters, Fisher 1301F/G High-Pressure Regulators, 25-micron Suction Strainers, Pump Setting Calibration Gauges, and Inline Discharge Check Valves.
  • Compatible Process Media: Methanol, monoethylene glycol (MEG), corrosion inhibitors, scale inhibitors, demulsifiers, biocides, oxygen scavengers, and boiler/desalination treatment chemicals.

 

Part Number Cross-References

  • Williams / Milton Roy Complete Assembly: CRP1000V400
  • Williams / Milton Roy Base Pump: P1000V400
  • Aluminum Cylinder Equivalent: CRP1000X400 / P1000X400
  • Higher Pressure 6″ Cylinder Variant: CRP1000V600 (4,700 PSIG max @ 150 PSIG air)
  • Double-Acting 8″ Cylinder Variant: CRP1000V800 (9,100 PSIG max @ 150 PSIG air, uses PO4-6S relay)
  • Single-Acting Relay Sub-Assembly: PO3-6S
  • IOM & Parts Manual Document ID: 30956 V Series IOM

 

Features

  1. Full 316 Stainless Steel Construction (V Series): Both the fluid end and the 4-inch pneumatic drive cylinder are machined from 316 SS, preventing galvanic corrosion and pitting in offshore salt-laden decks and engine rooms.
  2. High-Volume PO3-6S Servo Relay Actuation: Amplifies low-volume pneumatic pulses from the MK XIIA controller into rapid, full-bore air delivery to the 4-inch drive piston, preventing sluggish strokes at backpressures up to 2,300 PSIG.
  3. Dual-Seal Plunger Architecture with Leak Detection Port: Incorporates primary and secondary packing seals separated by a threaded tell-tale weep port, isolating process chemicals from the pneumatic drive chamber.
  4. 100:1 Dual-Axis Flow Turndown: Combines independent stroke-rate adjustment (1–45 SPM via controller needle valve) with mechanical stroke-length adjustment (0–100%), maintaining ±3% dosing accuracy across wide process load swings.
  5. Zero-Electricity Intrinsic Safety: Operates exclusively on instrument air or sweet natural gas (35–150 PSIG), eliminating electrical ignition hazards, VFDs, and explosion-proof junction boxes on FPSOs and chemical tankers.

 

Applications

  • Offshore Oil & Gas Wellhead Injection: Continuous dosing of methanol and kinetic hydrate inhibitors (KHI) into subsea flowlines, chokes, and gas lift manifolds.
  • Marine Engine Room & Boiler Water Treatment: Precision injection of oxygen scavengers, phosphate scale inhibitors, and alkalinity builders into high-pressure auxiliary marine boilers.
  • FPSO & Petrochemical Processing: Dosing of demulsifiers, biocides, Hâ‚‚S scavengers, and corrosion inhibitors into crude separation trains and produced water systems.
  • Reverse Osmosis (RO) & Desalination Plants: Antiscalant and sodium bisulfite injection upstream of high-pressure seawater membrane trains.

 

Frequently Asked Questions

What is the difference between Williams model P1000V400 and CRP1000V400?

P1000V400 designates the bare dual-seal plunger pump with a 1.000-inch plunger and 4.00-inch 316 stainless steel pneumatic motor cylinder. CRP1000V400 is the complete factory-configured assembly that includes the Controller (C – MK XIIA) and Pneumatic Servo Relay (R – PO3-6S) mounted to the pump (P).

Why does the P1000V400 require a PO3-6S pneumatic relay?

Pneumatic drive cylinders larger than 3.00 inches in diameter—such as the 4.00-inch cylinder on the P1000V400—require higher air/gas volume per stroke than the controller’s internal capillary circuit can pass directly. The PO3-6S single-acting pilot relay uses low-volume pneumatic pulses from the MK XIIA controller to switch a high-flow main air supply (35–150 PSIG), ensuring rapid plunger strokes and full exhaust venting.

Can the Williams Milton Roy P1000V400 run on natural gas instead of compressed air?

Yes. The V-Series pneumatic drive cylinder, MK XIIA controller, and PO3-6S relay are designed to operate on clean, dry, particulate-free instrument air or sweet natural gas regulated between 35 PSIG and 150 PSIG. When operating on natural gas, the 1/4″ NPT exhaust ports on the controller and relay must be piped to a safe flare or atmospheric vent header.

How does the V-Series P1000V400 differ from the X-Series P1000X400?

Both models share identical hydraulic performance, flow rates (9.08 GPH max), and pressure ratings (2,300 PSIG max). However, the V-Series utilizes 316 Stainless Steel for the pneumatic motor cylinder and external hardware, whereas the X-Series uses anodized aluminum for the pneumatic section. The V-Series is specifically specified for offshore platforms, marine vessels, and coastal chemical plants where salt-laden air rapidly corrodes aluminum housings.

What is the minimum air supply pressure needed to inject into a 1,500 PSIG process line?

To calculate the required relay air supply pressure, add a 200 PSI safety margin to your process discharge pressure and divide by the pump’s 15.38 amplification ratio: (1,500 + 200) / 15.38 = 110.5 PSIG. You must regulate the PO3-6S relay supply to at least 111 PSIG while keeping the MK XIIA controller pilot supply regulated at 35 PSIG.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.