ASCO ATS Control Unit D03ATSC30230HGX0

Condition: Used

Description

ASCO ATS Control Unit D03ATSC30230HGX0

The ASCO ATS Control Unit D03ATSC30230HGX0 is a microprocessor based intelligent control module specially designed for ASCO automatic transfer switches. This machine is intended to control crucial generator-to-utility transitions and continually samples voltage, frequency and phase characteristics across primary and emergency power sources. Designed for harsh maritime, offshore and heavy industrial situations, it conducts fail-safe switching sequences, provides source isolation and prevents simultaneous grid-generator feedback.

 

Model Details

  • Manufacturer: ASCO Power Technologies
  • Series Family: Series 300 / Series 230 Compatible Control Architecture
  • Manufacturer Part Number (MPN): D03ATSC30230HGX0
  • Item Classification: Primary ATS Microprocessor Control Unit / Logic Board

 

Technical Specifications: D03ATSC30230HGX0

Technical Parameter Specification Detail
Input Voltage Rating 125V to 300V AC (Line-to-Neutral sensing range); 220V–415V AC nominal system compatibility
System Frequency 50 Hz / 60 Hz auto-sensing
Control Power Supply High-frequency internal switch-mode power supply; external 24V DC auxiliary feed support
Terminal Allocation & Interfaces Plug-in cage-clamp terminal blocks; dedicated inputs for engine start/stop, auxiliary contacts, and RS-485 serial loops
Operating Temperature Range -20°C to +70°C
Relative Humidity Up to 95% non-condensing (conformal coated for marine environments)
EMC Compliance IEC 61000-4-2 through 61000-4-11; CISPR 11 Class A emissions

 

Special Features

  1. Microprocessor Intelligence: High frequency digital sampling architecture monitors under/over voltage, frequency differentials and phase rotation abnormalities.
  2. Non-Volatile Event Logging: Stores internal critical system event history, parameter settings, and problem diagnostics during complete auxiliary power failure.
  3. Integrated Communication Ports: Powerful hardware interfaces (optional RS-485 configurations available) for easy SCADA, PLC and PMS (Power Management System) connectivity.
  4. Configurable Operating Modes Supports field-selectable parameters like Source I/Source II priority selection, time-delay overrides, and engine exerciser schedules.

 

Compatibility

  • Compatible Switch Series: Designed for integration within ASCO Series 300 and select modular Series 230 Automatic Transfer Switches.
  • System Match: Fully compatible with 3-pole and 4-pole contactor and switch-based configurations operating up to 415V AC.

 

Industrial Applications

  • Marine and offshore dynamic positioning and emergency switchboards
  • Commercial building backup generation and life-safety systems
  • Mission-critical data center redundant power networks
  • Telecommunication central office backup architecture
  • Industrial continuous process manufacturing plant grids

 

Marine Engineer Expert’s Guide

1) Conformal Coating Inspection for Marine Retrofits:

When installing this unit in high-humidity engine control rooms or marine bulkheads, verify that the board’s conformal coating is completely free of micro-abrasions. Salt-laden moisture ingress across unsealed terminal pins can trigger false phase-loss flags on the controller LCD.

2) Auxiliary 24V DC Backfeed Setup:

For applications requiring uninterrupted controller monitoring during deep source dropouts, configure an isolated external 24V DC power supply to the designated board terminals. This keeps the microprocessor alive and logs fault criteria without requiring full line-voltage restoration.

3) Firmware & Calibration Handshake:

Always match the exact firmware checksum version when replacing control boards in legacy ASCO frames. Mismatched time-delay parameters between the display module and core logic board can lead to transfer hunting under weak generator frequencies.

 

Frequently Asked Questions

What triggers the ASCO ATS Control Unit D03ATSC30230HGX0 to initiate a transfer?

The unit continuously tracks normal source voltage and frequency parameters. If the primary line dips below programmed thresholds (typically under 70% to 85% of nominal) or experiences a complete phase loss, the controller initiates the engine-start contact sequence, waits for generator stabilization, and commands the switch mechanism to transfer the load.

Can this control unit be configured for manual override operations?

Yes. The D03ATSC30230HGX0 supports automated, remote, and manual operating states, permitting safe physical or electrical intervention during routine maintenance or emergency overrides.

Is historical event data preserved during a total power failure?

Yes. The integrated non-volatile memory stores system logs, calibration settings, and fault event history indefinitely, even if both utility and auxiliary power feeds are completely lost.

How do I verify if this specific part number matches my existing switch frame?

Verify the catalog number prefix on your current ATS door label and cross-reference the control power rating. The D03ATSC30230HGX0 is explicitly tailored for multi-voltage 50/60Hz configurations utilizing the advanced C300-class logic core interface.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.