Endress+Hauser PMC 133-1M1F9PWD3W Pressure Transmitter IP65
The Endress+Hauser PMC 133-1M1F9PWD3W is a 2-wire gauge pressure transmitter from the legacy Cerabar PMC 133 line. Built around an oil-free, dry capacitive ceramic measuring cell, it converts low-range gauge pressure (-20 to +20 mbar) into a standard 4…20 mA analog current loop signal.
The dry ceramic diaphragm avoids fill-fluid thermal expansion errors and eliminates the risk of process contamination if the membrane ruptures. Housed in an IP65-rated cast aluminum enclosure with a PG16 cable gland, this unit handles high-vibration engine rooms, cargo pump rooms, and utility piping.
Model Details
- Manufacturer: Endress+Hauser Instruments International GmbH+Co.
- Series: Cerabar PMC 133
- Full Model / MPN: PMC 133-1M1F9PWD3W (Variant string: PMC 133 1M1F9PWD3W)
- Factory Order Code Decoding:
- 1: Process Connection Material — 1.4581 Stainless Steel (316Ti equivalent)
- M: Process Connection Thread — External G 1/2″ per DIN 16288
- 1F: Process Seal / Gasket — Viton (FKM) standard elastomer
- 9: Electronics Output — Special version factory-configured for 4…20 mA, 2-wire loop with integrated signal damping (3–4 sec)
- P: Housing Version — Cast aluminum housing, PG16 cable entry, IP65 protection
- W: Accuracy Class — Factory-calibrated special version
- D3W: Measuring Range Code — Low-pressure cell (Psens: 0.4 bar) factory-calibrated to -20…+20 mbar (max overpressure 10 bar)
Technical Specifications: Endress+Hauser PMC 133-1M1F9PWD3W
| Specification Parameter | Technical Value |
|---|---|
| Manufacturer | Endress+Hauser |
| Series / Model | Cerabar PMC 133 |
| Manufacturer Part Number (MPN) | PMC 133-1M1F9PWD3W |
| Sensor Technology | Dry capacitive ceramic cell (oil-free) |
| Pressure Measurement Type | Gauge (Relative) |
| Calibrated Measuring Range | -20 to +20 mbar (-2 to +2 kPa) |
| Nominal Sensor Range (Psens) | 0.4 bar (400 mbar) |
| Maximum Overpressure Limit (Pmax) | 10 bar (1.0 MPa) |
| Output Signal | 4…20 mA, 2-wire loop |
| Signal Damping | 3 to 4 seconds (factory preset) |
| Supply Voltage (U) | 11.5 to 36.5 V DC |
| Terminal Allocation | Terminal 1: +Supply (11.5-36.5V DC) | Terminal 2: -Signal (4-20mA) | Terminal 3: Test Diode |
| Zero & Span Calibration | Internal potentiometers: Z (Zero) and S (Span) |
| Process Connection | G 1/2″ Male Thread (DIN 16288) |
| Process Connection Material | 1.4581 Stainless Steel (316Ti equivalent) |
| Wetted Seal Material | Viton (FKM) |
| Linearity & Hysteresis | Linearity: ±0.2% to ±0.5% FS | Hysteresis: ≤0.1% FS |
| Ambient Temperature Range | -20°C to +70°C |
| Process Temperature Range | -20°C to +80°C (+130°C short-term) |
| Housing Material & Cable Entry | Cast Aluminum, PG16 Cable Gland |
| Ingress Protection Rating | IP65 (IEC 60529) |
Features
- High Overload Resistance: The 0.4 bar ceramic measuring cell withstands up to 10 bar of overpressure—25 times its nominal span—preventing diaphragm rupture during line surges or improper valve sequencing.
- Oil-Free Ceramic Diaphragm: Eliminates silicone or fluorocarbon fill fluids, removing thermal drift caused by fluid expansion and preventing process contamination in sensitive ballast or potable systems.
- Factory-Set Signal Damping (3–4 sec): Smooths out high-frequency pressure pulsations from reciprocating pumps, scavenge air blowers, and engine room ventilation fans before the signal reaches the PLC.
- Wide 11.5–36.5 V DC Loop Supply: Operates reliably across standard 24 V DC marine automation buses even during shipboard battery voltage dips.
- Corrosion-Resistant Wetted Parts: Combines a 1.4581 (316Ti) stainless steel G 1/2″ process connection with a Viton (FKM) seal for continuous exposure to fuel vapors, lube oil mist, and marine air.
Applications
- Marine Engine Room & Auxiliary Systems:
- Scavenge air receiver and turbocharger air intake differential/draft pressure monitoring.
- Boiler combustion air draft, furnace pressure, and inert gas system (IGS) scrubber pressure control.
- Crankcase mist extraction vacuum and engine room ventilation duct pressure.
- Hydrostatic tank level gauging in day tanks, sludge tanks, and ballast water systems.
- Industrial Process Control:
- Baghouse filter differential pressure and cleanroom/HVAC duct static pressure monitoring.
- Low-pressure gas distribution lines, vapor recovery units, and pneumatic conveying blowers.
Compatibility & Cross-References
- Compatible Control Systems: Connects directly to any 24 V DC analog input module (4–20 mA) on Kongsberg Norcontrol, Wärtsilä NACOS / Valmatic, Siemens SIMATIC S7-300/400/1500, Allen-Bradley ControlLogix, and ABB Advant / AC 800M systems.
- Official Endress+Hauser Successor: The Cerabar PMC 133 series is discontinued and officially superseded by the Endress+Hauser Cerabar M PMC41 (specifically configuration PMC41-RE11… with G 1/2″ thread, 316L/ceramic cell, and 4…20 mA output).
- Predecessor Models: Replaces legacy Endress+Hauser Cerabar PMC 330 and PMC 430Z transmitters.
- Functional Cross-References (Form/Fit Check Required):
- Vega VEGABAR 14 / VEGABAR 28: Ceramic capacitive cell, G 1/2″ DIN 3852-A, 4–20 mA 2-wire.
- Keller Series 23SY / 25Y: Low-range gauge transmitter with G 1/2″ process connection.
Frequently Asked Questions
What is the measuring range and output signal of the Endress+Hauser PMC 133-1M1F9PWD3W?
This specific model code is factory-configured for a gauge pressure span of -20 to +20 mbar using a 0.4 bar nominal ceramic cell, and outputs a standard 4…20 mA 2-wire analog signal with 3–4 seconds of built-in damping.
How do I wire the 4–20 mA loop on the PMC 133 aluminum housing?
Open the top housing cover to access the terminal block. Connect the positive DC supply (+11.5 to +36.5 V DC) to Terminal 1 (+) and the 4–20 mA signal return to Terminal 2 (-). Connect the cable shield to the internal ground screw. Terminal 3 is reserved for non-intrusive multimeter current testing via the internal interlock diode.
Can the Endress+Hauser PMC 133-1M1F9PWD3W survive accidental overpressure?
Yes. While the calibrated span is -20 to +20 mbar, the dry ceramic measuring cell has a nominal rating of 0.4 bar and a maximum overpressure limit of 10 bar without permanent calibration shift or diaphragm damage.
What is the direct replacement for the discontinued Endress+Hauser PMC 133?
Endress+Hauser officially replaced the Cerabar PMC 133 series with the Cerabar M PMC41. For a mechanical and electrical drop-in replacement, specify a PMC41 with a G 1/2″ stainless steel process connection, FKM (Viton) seal, 0.4 bar ceramic sensor, and 4…20 mA 2-wire output.
Is the PMC 133-1M1F9PWD3W suitable for marine engine room installation?
Yes. Its IP65 cast aluminum enclosure, 1.4581 stainless steel process connection, dry oil-free ceramic sensor, and factory 3–4 second damping make it well suited for marine engine rooms, boiler draft measurement, and tank level monitoring where vibration and pressure pulsations are common.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.