RIKEN KEIKI SD-1EC(EX) Smart Transmitter & Gas Detector
Condition: New
Country of Origin: Japan
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
RIKEN KEIKI SD-1EC(EX) Smart Transmitter / Gas Detector
The RIKEN KEIKI SD-1EC(EX) is an explosion-proof smart gas transmitter and detector head engineered for continuous toxic gas monitoring in Zone 1 and Zone 2 hazardous environments. Operating on the potentiostatic electrolysis (electrochemical) detection principle, this diffusion-type unit detects Hydrogen Sulfide or Carbon Monoxide and converts concentration levels into a linear 4–20 mA DC analog output (with optional HART protocol support on Type H/HS variants).
Housed in a compact, weather-resistant cast enclosure rated to IP65/IP67 and certified for IIC gas groups (including Hydrogen and Acetylene), the unit integrates a local 4-digit, 7-segment LED readout and microprocessor-driven self-diagnostics. Operators perform zero/span calibration and menu navigation non-intrusively through the glass window using a dedicated magnetic control key, eliminating the need to declassify hazardous zones or open the flameproof cover during routine maintenance.
Model Details
- Manufacturer: RIKEN KEIKI Co., Ltd. (Tokyo, Japan)
- Primary Model / MPN: SD-1EC(EX) (Export ATEX/IECEx Specification)
- Series: SD-1 Series Fixed Smart Gas Transmitters
- Variant Designations:
- SD-1EC — Standard 3-wire 4–20 mA analog output with programmable SPST (1a) alarm relay contact.
- SD-1EC (TYPE H / TYPE HS) — 4–20 mA + HART 7 communication variant (no mechanical alarm relay; digital diagnostics over analog loop).
- SD-1DEC — Sample-draw (suction) equivalent requiring an external aspirator or pump unit (SD-1DEC-AS / RP-D58).
Features
- IIC Flameproof Construction (Ex db IIC T6 Gb): Certified under ATEX and IECEx for deployment in explosive gas atmospheres containing Group IIC gases such as Hydrogen and Acetylene, as well as Group IIB/IIA hydrocarbons.
- Non-Intrusive Magnetic Calibration: Hall-effect magnetic switches allow single-operator zero adjustment, span calibration, and alarm setpoint verification through the enclosure window without opening the flameproof housing.
- Continuous Microprocessor Self-Diagnostics: Monitors sensor integrity, internal circuitry, and power stability, automatically triggering a yellow FAULT LED and displaying specific diagnostic error codes on the 7-segment readout.
- Low Power Draw & Long-Distance Transmission: Operates at a maximum power consumption of 1.1 W on 24 VDC (17–26.4 VDC), supporting shielded cable runs up to 1.25 km using 1.25 mm² CVVS cable.
RIKEN KEIKI SD-1EC(EX) Technical Specifications
| Specification Parameter | Technical Value / Rating |
|---|---|
| Manufacturer / Model | RIKEN KEIKI Co., Ltd. / SD-1EC(EX) |
| Detection Principle | Potentiostatic Electrolysis (Electrochemical Sensor) |
| Sampling Method | Diffusion Type (Optional aspiration adapter supported) |
| Detectable Gases & Standard Ranges | Hydrogen Sulfide (H2S): 0–30 ppm Carbon Monoxide (CO): 0–75 ppm |
| Display & Status Indicators | 4-Digit 7-Segment Red LED; Green POWER LED, Red ALM LED, Yellow FAULT LED |
| Power Supply Input | 24 VDC Nominal (Operating Range: 17.0 VDC to 26.4 VDC) |
| Power Consumption | Max. 1.1 W (Approx. 45 mA at 24 VDC) |
| Analog Transmission Output | 4–20 mA DC Linear (3-wire common power/signal; Load resistance < 300 Ohms; 200-division resolution) |
| Digital Communication (Optional) | HART 7 Protocol over 4–20 mA loop (TYPE H / TYPE HS models; replaces mechanical relay) |
| Alarm Relay Contact (Standard) | 1x SPST (1a) Dry Contact, Configurable NO/NC (Gas Alarm, Fault Alarm, or Common Alarm) |
| Relay Contact Capacity | 250 VAC 0.5 A or 30 VDC 0.5 A (Resistive Load) |
| Alarm Accuracy & Response Delay | Within ±30% of alarm setpoint; ≤ 30 seconds at 1.6x alarm gas concentration |
| Initial Clear Time | Approx. 25 seconds |
| Transmission Cable & Max Distance | Shielded CVVS 1.25 mm² (3-core analog / 5-core with relay); Max. 1.25 km |
| Explosion-Proof Rating | ATEX: II 2G Ex db IIC T6 Gb (DEKRA 13ATEX0035 X) IECEx: Ex db IIC T6 Gb (IECEx DEK 13.0024X) |
| Functional Safety Rating | SIL 2 Certified (IEC 61508 Parts 1–7, Single Application HFT=0) |
| Ingress Protection | IP65 / IP67 Equivalent |
| Operating Temperature | -20°C to +60°C (ATEX/IECEx certification range) / -10°C to +40°C (Continuous sensor window) |
| Operating Humidity | 30% to 80% RH (Non-condensing) |
| Dimensions & Weight | Approx. 148 (W) × 203 (H) × 88 (D) mm (excluding projections); Approx. 2.2 kg |
Standard 3-Wire Analog + Relay Version (SD-1EC)
- Terminal 1 (+24V): 24 VDC Power Supply Positive (+)
- Terminal 2 (Sig / 4-20mA): 4–20 mA Analog Signal Output Positive (+)
- Terminal 3 (GND / COM): Power Supply Negative (-) and 4–20 mA Signal Common (-)
- Terminals 4 & 5 (ALM / RELAY): Dry Contact Output (1a / SPST) — connects to external beacon, buzzer, or PLC discrete input (5-core CVVS cable required when utilized)
HART Communication Version (SD-1EC TYPE HS)
- Terminal 1 (DC+): 24 VDC Power Supply Positive (+)
- Terminal 2 (DC-): 24 VDC Power Supply Negative (-)
- Terminal 3 (Sig+): 4–20 mA + HART Signal Positive (+)
- Terminal 4 (Sig-): 4–20 mA + HART Signal Negative (-)
Compatibility
- RIKEN KEIKI Indicator / Alarm Controllers: RM-5000 Series, RM-5003, RM-6000 Series
- RKI Instruments Controllers (North American Equivalents): Beacon 110, Beacon 410A, Beacon 800
- Third-Party Automation Systems: Any industrial PLC, DCS, or F&G logic solver accepting a 3-wire sourcing 4–20 mA DC input with a loop impedance under 300Ω.
Part Number Cross-References
- RIKEN KEIKI Export / ATEX-IECEx Model: SD-1EC(EX) / SD-1EC
- RKI Instruments (US Market Equivalent): SD-1 Series Electrochemical Transmitter (65-2645RK / SD-1EC)
- Related SD-1 Series Cross-References (By Sensor Technology):
- SD-1GP / SD-1NC — Catalytic Combustion (% LEL Combustible Gases)
- SD-1RI — Non-Dispersive Infrared / NDIR (% LEL Hydrocarbons
- SD-1OX — Galvanic Cell (0–25% / 0–50% Vol. Oxygen
- SD-1GH — Metal Oxide Semiconductor / MOS (Low-ppm VOCs & Toxic Vapors)
Frequently Asked Questions
What is the difference between the RIKEN KEIKI SD-1EC and the SD-1EC(EX)?
The SD-1EC(EX) designates the export explosion-proof specification certified under international ATEX (II 2G Ex db IIC T6 Gb) and IECEx (Ex db IIC T6 Gb) directives for hazardous zones outside Japan. Domestic Japanese units carry TIIS (Japan Ex) certification with a slightly narrower ambient temperature rating
Can the SD-1EC(EX) be installed in atmospheres containing Hydrogen or Acetylene?
Yes. The flameproof enclosure is certified to Gas Group IIC (Ex db IIC T6 Gb), which covers the most easily ignited industrial gases, including Hydrogen and Acetylene, in addition to Group IIA and IIB gases.
How is the RIKEN KEIKI SD-1EC(EX) calibrated in a hazardous area?
Calibration is performed non-intrusively using the supplied magnetic control key. Placing the magnetic key over the MENU/ESC, SET, UP, and DOWN markings on the front faceplate activates internal Hall-effect switches, allowing technicians to enter maintenance mode, perform zero air adjustments, and apply span gas via the calibration cap without opening the explosion-proof housing.
Does the SD-1EC(EX) support both HART communication and a relay output simultaneously?
No. Standard SD-1EC transmitters include a 3-wire 4–20 mA analog output paired with a single programmable SPST (1a) dry relay contact. The HART-enabled variant (SD-1EC TYPE H / HS) utilizes a 4-wire terminal layout (DC+, DC-, Sig+, Sig-) to superimpose HART 7 digital diagnostics over the 4–20 mA loop and omits the mechanical alarm relay.
How often should the electrochemical sensor cell be replaced and calibrated?
RIKEN KEIKI recommends functional bump testing and span calibration every 6 months to maintain safety compliance and SIL 2 integrity. Depending on ambient temperature, humidity, and background gas exposure, the electrochemical sensor element typically requires replacement every 2 to 3 years.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.