Honeywell CC-PDIS01 Digital Input Module 24VDC SOE
$3,999.00
Condition: New Seal Pack
3 in stock
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Honeywell CC-PDIS01 Digital Input Module – 32-Channel 24VDC SOE Monitoring
The Honeywell CC-PDIS01 (Manufacturer Part Number: 51405042-176 / 51405042-175) is an industrial-grade, 32-channel discrete sequence of events (DISOE) module engineered for the Honeywell Experion® Process Knowledge System (PKS) Series C architecture. Designed to meet the stringent demands of high-reliability process automation, offshore machinery spaces, and marine power plants, the CC-PDIS01 captures discrete field contact states with hardware-level 1-millisecond resolution time-stamping.
Operating natively at nominal 24VDC, this module eliminates ambiguity during complex plant trip sequences, turbine emergency shutdowns (ESD), and generator switchgear operations. By logging digital state transitions directly at the I/O bus interface rather than relying on standard controller cycle scans, the CC-PDIS01 prevents root-cause obfuscation during cascading alarms. It mounts onto specialized Series C Input/Output Termination Assemblies (IOTAs), featuring conformal coating to protect sensitive logic arrays from corrosive salt mist, hydrogen sulfide, thermal shock, and high-vibration maritime environments.
Model Details
- Model Number: CC-PDIS01
- Base MPN / Hardware Part Numbers:
- 51405042-176 (Standard coated production revision)
- 51405042-175 (Functional equivalent hardware revision)
- Related Functional Siblings:
- CC-PDIL01 / 51405040-175 (Standard 24VDC Digital Input Module without 1ms SOE tagging)
- 8C-PDISA1 (Series 8 equivalent form-factor DISOE module)
- Matching Termination Assemblies (IOTA):
- CC-TDIS01 / 51308365-175 (Non-redundant 32-channel IOTA, 9-inch)
- CC-TDIS11 / 51308365-275 (Redundant 32-channel IOTA, 12-inch)
Technical Specifications
| Parameter | Engineering Specification |
|---|---|
| Number of Channels | 32 Discrete Input Channels |
| Nominal Operating Voltage | 24 VDC (Sink / Dry-contact excitation compatible) |
| Input Voltage Range | 18.0 VDC to 30.0 VDC |
| ON-State Sensing Threshold | > 13.0 VDC (Sense current nominal: 2.0 mA to 5.0 mA) |
| OFF-State Sensing Threshold | < 5.0 VDC (Sense current nominal: < 0.5 mA) |
| Time Resolution (SOE Mode) | 1 millisecond (1 ms) hardware-tagged resolution |
| PV Scan Execution Speeds | Normal: 20 ms | SOE Scan: 20 ms | Low Latency: 5 ms |
| Dielectric Galvanic Isolation | 1500 VAC RMS or ±1500 VDC (Field-to-Logic Common) |
| Field Contact Types | Potential-free relay contacts, solid-state switches, proximity sensors |
| Internal Power Consumption | Nominal 4.5 W (excluding loop interrogation draw) |
| Operating Temperature Range | -40°C to +70°C (-40°F to +158°F) |
| Storage Relative Humidity | 5% to 95% non-condensing |
| Vibration Resistance | 1.0 G operational shock / vibration compliance (5 to 150 Hz) |
| Hazardous Location Ratings | Class I, Division 2, Groups A, B, C, D; ATEX / IECEx Zone 2 |
Key Features
- Sub-Millisecond Event Attribution: Provides true 1 ms hardware-clock time-stamping on all 32 channels simultaneously, enabling unambiguous post-trip root cause analysis across complex interlocks.
- Configurable Operational Scanning Modes: Supports three software-selectable execution modes: Normal Mode (20 ms process variable scan), SOE Mode (1 ms event capture resolution with 20 ms scan), and Low Latency Mode (5 ms deterministic scan).
- Advanced Open-Wire & PV Diagnostics: Features comprehensive line integrity monitoring that detects severed field loops and flags process variables as “Invalid” to prevent unintended control actions.
- Flexible Excitation Architecture: Field loop interrogation voltage can be routed from onboard Series C filtered power distribution or driven via galvanically separated external non-incendive power networks.
Compatibility
- Controllers: C300 Controller, C300-CNI, and Embedded Simulation Processors.
- Compatible IOTA Carrier Bases:
- Non-Redundant: CC-TDIS01
- Redundant: CC-TDIS11
- System Engineering Software: Experion Control Builder (Engineering Studio) R300, R400, R430, R500, and R510+ series.
- Cabinet Power Systems: Integrates with Honeywell standard power distribution units (e.g., CC-PWRR01, CC-PWRN01).
Applications
- Marine Dynamic Positioning (DP2/DP3) Thruster Trips: Capturing synchronous trip feedback from electric propulsion drives, hydraulic valves, and steering gear systems to detect failure propagation.
- Turbomachinery & Gas Compressor Protection: High-speed monitoring of turbine overspeed trips, lube-oil pressure collapse, and flame detection interlocks.
- Marine Emergency Shutdown (ESD) Systems: Real-time logging of bridge pushbuttons, gas release valves, bulk-cargo vapor alarms, and machinery-space water ingress switches.
- High-Voltage Marine Switchgear Trip Coordination: Sequence-of-events recording across medium-voltage vacuum circuit breakers (VCB), generator reverse-power relays, and bus-tie tiebreakers.
- Boiler & Burner Management Systems (BMS): Microsecond-accurate tracking of purge verification, fuel shut-off valving, and draught fan pressure failures.
Frequently Asked Questions
What is the functional difference between the Honeywell CC-PDIS01 and CC-PDIL01?
The CC-PDIS01 is designed for Sequence of Events (SOE) logging with dedicated hardware-level 1-millisecond resolution time-stamping. The CC-PDIL01 is a standard discrete input module that updates states on the standard 20ms controller cycle without sub-millisecond event tags.
Can the CC-PDIS01 run in redundant configurations?
Yes. When paired with the redundant 12-inch IOTA carrier (CC-TDIS11), two CC-PDIS01 modules operate in a redundant pair. The secondary module tracks active field transitions and can execute bumpless failover without losing event sequence history.
Does the CC-PDIS01 provide loop power for dry contacts?
Yes. The module supports internally wetted power topologies from the Series C internal power rail, as well as externally marshalled 24VDC supplies. This eliminates the need for external interposing relays on low-power dry contact loops.
What causes an “Invalid PV” alarm state on a CC-PDIS01 channel?
An “Invalid PV” status indicates that internal diagnostics detected an open-wire field loop fault or out-of-spec sense current, causing the module to lock the channel’s process variable to prevent downstream logic errors.
Are CC-PDIS01 modules interchangeable between Series C and Series 8 racks?
No. The CC-PDIS01 is built for Honeywell Experion Series C racks and IOTA bases. Series 8 systems utilize the alternate form-factor module part number 8C-PDISA1.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.