Honeywell DC1040CL-302000-E Temperature Controller
Condition: New
Country of Origin: Taiwan
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Honeywell DC1040CL-302000-E Temperature Controller
The Honeywell DC1040CL-302000-E is a microprocessor-based 1/4 DIN (96 x 96 mm) digital process and temperature controller engineered for precision closed-loop control in mission-critical thermal, pressure, and fluid regulation loops. Built on Honeywell’s rugged DC1000 hardware architecture, this instrument operates across an extended power input range of AC 85V to 265V (50/60 Hz) with a nominal power demand of 6VA to 8VA at 50°C.
The DC1040CL-302000-E combines a 14-bit analog front-end conversion engine with a rapid 500 ms sampling cycle. It accepts configurable universal inputs (including standard RTDs, multiple thermocouple chemistries, and linear current/voltage signals) and produces an isolated, continuous 4–20 mA DC linear control output tailored for modulating pneumatic control valve positioners, variable frequency drives, or solid-state power stacks.
The unit features an IP65-rated splash- and dust-resistant front fascia, tactile membrane navigation keys, dual high-luminance 4-digit 7-segment LED arrays (Process Value in red, Set Point in green), and a 10-segment LED bargraph that delivers real-time visual tracking of manipulated variable (MV) output percentage. Dual independent SPST/SPDT electromechanical alarm relays provide continuous perimeter supervision for system interlocks, burner safety trip circuits, and high/low limit plant alarms.
Manufacturer Part Number (MPN) & Cross References
- Exact MPN: DC1040CL-302000-E (also listed in field maintenance logs as DC1040CL-302-000-E)
- Compatible Drop-in Alternatives & Sibling Models:
- DC1040CR-302000-E: Identical 1/4 DIN chassis, AC 85–265V power, dual alarm relays, but equipped with an electromechanical Relay Contact output (5A/250VAC) for Output 1 instead of 4–20 mA.
- DC1040CT-302000-E: Identical 1/4 DIN chassis, AC 85–265V, dual alarms, equipped with a Voltage Pulse (SSR Driver, 20VDC/20mA) Output 1.
- DC1020CL-302000-E: 1/8 DIN vertical chassis (48 x 96 mm) with matching I/O and loop capabilities.
- DC1010CL-302000-E: 1/16 DIN compact chassis (48 x 48 mm) with matching linear output specifications.
- Legacy Field Replacements: Replaces older Honeywell UDC2000, UDC2300, and UDC2500 panel units running simple continuous-current 4–20 mA single-loop thermal control.
Technical Specifications
| Parameter / Specification | Technical Rating & Functional Capacity |
|---|---|
| Manufacturer & Series | Honeywell Process Solutions — DC1000 Digital Controller Family |
| Model / MPN | DC1040CL-302000-E |
| Physical Dimensions | 1/4 DIN format; Bezel: 96 mm (W) x 96 mm (H); Depth behind panel: 100 mm |
| Panel Cutout Dimensions | 92.0 mm (+0.8 mm / -0 mm) x 92.0 mm (+0.8 mm / -0 mm) |
| Operating Supply Voltage | AC 85V to 265V, universal wide-range switchmode, 50/60 Hz |
| Power Consumption | 6VA at AC 110V; 8VA max at AC 220V / 50 Hz |
| Analog Input Channels | 1 Universal isolated input channel; 14-bit internal A/D resolution |
| Thermocouple Input Types | K (-50 to 1370°C), J (-50 to 1000°C), R (-50 to 1750°C), S (-50 to 1750°C), B (0 to 1800°C), E, N, T, W5, PL-II, U, L |
| RTD Sensor Types | Pt100 (DIN/IEC 751, -200 to +600°C), JPt100, JPt50 (3-wire configuration) |
| Linear Input Ranges | 0–20 mA, 4–20 mA DC (via built-in or external 250 Ω shunt); 0–1V, 0–5V, 1–5V, 0–10V DC |
| Measurement Accuracy | ±0.2% to ±0.3% of full span ±1 digit at 25°C calibration ambient |
| Sampling Cycle Speed | 500 milliseconds (2 updates per second) |
| Primary Output 1 (OUT1) | Continuous Linear DC Current: 4–20 mA DC (configurable to 0–20 mA); Max Loop Load: 500 Ω |
| Alarm Outputs (AL1, AL2) | 2 Independent Electromechanical Relays; SPST Form A; Rated 3A @ 240VAC (Resistive Load) |
| Control Algorithms | PID with Auto-tuning, PD, PI, P-only, or ON/OFF with configurable hysteresis |
| Display Interface | Dual 4-digit 7-segment LED (Upper PV: Red 14 mm; Lower SP: Green 10 mm); 10-point MV bargraph |
| Data Retention & Security | Non-volatile EEPROM memory (>10 years data retention); 4-digit passcode security lockout |
| Insulation & Dielectric Resistance | >10 MΩ at 500VDC between terminals and ground; Dielectric: 1500VAC for 1 min (I/O to Case) |
| Environmental Ratings | Operating: 0°C to +50°C; Storage: -25°C to +65°C; Permissible Humidity: 20% to 90% RH non-condensing |
| Ingress Protection Level | Front Panel: IP65 / NEMA 4 (water/dust spray resistant); Rear Terminals: IP20 |
| Unit Weight | Approx. 420 grams (unboxed chassis with mounting brackets) |
Compatibility
- Marine Auxiliary Boilers & Steam Generators: Aalborg, KangRim, Miura, and Clayton marine steam boilers. Drives 4–20 mA electro-pneumatic positioners on heavy fuel oil (HFO) preheating lines and feed-water bypass valves.
- Fuel Oil Conditioning & Booster Modules: Alfa Laval, Auramarine, and GEA Westfalia fuel booster systems. Modulates viscosity control steam heaters and thermal oil secondary loops.
- Thermal Fluid Heaters: HTI, Wiesloch, and Konus-Kessel thermal oil circuits.
- Inert Gas Systems (IGS) & Marine Incinerators: KangRim, TeamTec, and Atlas incinerators for flue gas and burner chamber limit monitoring.
- Industrial Thermal Processing: Plastics injection molding manifolds, packaging lines, continuous drying ovens, annealing furnaces, and HVAC secondary heat exchangers.
Applications
- Marine & Shipboard Systems:
- Heavy Fuel Oil (HFO) & Marine Gas Oil (MGO) viscosity control temperature loops.
- Auxiliary boiler steam drum pressure/temperature cascade monitoring.
- Main propulsion engine jacket water cooling fresh water (HT/LT) loop modulation.
- Exhaust gas economizer bypass damper and soot collection temperature tracking.
- Marine sewage treatment plant aeration heating and incinerator combustion control.
- Industrial & Manufacturing Processes:
- Plastic injection molding barrels, extruders, and hot runner manifold regulation.
- Industrial conveyor drying tunnels, textile setting ovens, and paint baking booths.
- Chemical reaction vessels, autoclave sterilizers, and distillation columns.
- Commercial food ovens, brewery kettle steam jackets, and packaging heat seal bars.
Frequently Asked Questions
What does the “CL” in the Honeywell DC1040CL part number designate?
The “C” designates a standard PID digital controller with heat/cool algorithms, while the “L” specifies a continuous Linear Current/Voltage control output (configured from the factory as 4–20 mA DC). This differs from the “CR” model (electromechanical Relay output) and the “CT” model (Solid State Relay driver voltage pulse).
What is the primary control output signal of the DC1040CL-302000-E?
The primary control output (OUT1) across terminals 5 and 6 provides an isolated, continuous 4–20 mA DC signal into an external load impedance of up to 500 Ω. It is used for proportional throttling of control valves, variable speed drives, or phase-angle thyristor stacks.
Can the input channel accept RTD and Thermocouple sensors without hardware changes?
Yes. The DC1040 features a universal 14-bit analog input. You can switch between PT100 RTDs, thermocouples (K, J, R, S, T, E, B, N), or linear DC current/voltage inputs entirely through the front membrane keyboard in the Level 3 (INP1) configuration menu without modifying internal jumpers.
What are the ratings of the internal alarm relays?
The two internal alarm relays (AL1 and AL2) are single-pole single-throw (SPST Form A) contacts rated for a maximum resistive load of 3 Amps at 240 Volts AC (or 3A @ 30VDC). They can be independently programmed for high deviation, low deviation, process high, process low, band, or sensor break alarms.
How do you perform an auto-tuning routine on this controller?
Access the Level 1 parameter menu by pressing the SET key, navigate to the AT parameter, and toggle the value to “YES”. The yellow “AT” indicator on the front bezel will illuminate while the controller cycles the process to determine optimal Proportional, Integral, and Derivative constants. When complete, the controller automatically writes the new parameters to non-volatile EEPROM and returns to normal PID regulation.
Does the controller retain configuration parameters during a power blackout?
Yes. All configuration values, process set points, calibration numbers, and alarm thresholds are stored in industrial non-volatile EEPROM with data retention exceeding 10 years without requiring a backup battery.
What is the required panel cutout size for installation?
The DC1040 follows standard 1/4 DIN industrial panel dimensions: a 96 mm x 96 mm exterior front bezel requiring a square panel cutout of 92.0 mm x 92.0 mm (tolerance +0.8 mm / -0.0 mm) with a clearance depth of at least 100 mm behind the panel face.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.

