Mettler Toledo Thornton 3000CS Chloride Sulfate Analyzer (MPN: 58044001)

The Mettler Toledo Thornton 3000CS Chloride Sulfate Analyzer (MPN: 58044001) provides semi-continuous, online trace-level detection of corrosive chloride ions in high-purity water systems. Operating on microcapillary electrophoresis (MCE) technology paired with an integrated M800CS touchscreen transmitter, it separates ions across an electrolyte-filled channel and measures conductivity at the end of the path without interference from common boiler treatment additives such as ammonia, morpholine, or hydrazine.

The 3000CS consolidates its sample conditioning, fluidics, reagent reservoirs, and transmitter electronics inside a single locking cabinet, eliminating external auxiliary mounting hardware.

 

Model Details

  • Manufacturer: Mettler-Toledo Thornton, Inc.
  • Model Series: 3000CS Analyzer
  • Manufacturer Part Number (MPN): 58044001
  • Transmitter Interface: Integrated M800CS Color Touchscreen Transmitter with Intelligent Sensor Management (ISM)
  • Measurement Principle: Microcapillary Electrophoresis (MCE) with Conductivity Detection

 

Features

  1. Direct Trace Ion Separation: Quantifies chloride down to a 0.5 ppb limit of detection and sulfate down to 1 ppb (0–300 ppb range) using microcapillary electrophoresis, avoiding false positives caused by pH-conditioning amines.
  2. Configurable Cycle Interval: Executes automated measurement cycles every 45 minutes by default (programmable from 15 to 60 minutes) to balance rapid excursion response against reagent consumption.
  3. Self-Contained Dual-Rating Cabinet: Houses electronics rated to IP66 / NEMA 4X and a reagent/fluidics compartment rated to IP55, protecting internal components from moisture and dust.
  4. Built-In Grab Sample Port: Features an integrated 100 mL grab sample capacity for manual verification testing from auxiliary sample points without disrupting the main sample line.
  5. Comprehensive SCADA & DCS Output: Equips operators with 8 powered 0/4–20 mA analog outputs (with 22 mA fault alarm) and 8 programmable relays (4 mechanical SPDT, 4 reed) for direct PLC/DCS integration and automated boiler blowdown control.

 

Technical Specifications

Parameter Specification / Rating
Manufacturer / Model Mettler Toledo Thornton 3000CS (MPN: 58044001)
Measurement Technology Microcapillary Electrophoresis (MCE) with Conductivity Detection
Chloride Measurement Range 0 to 300 ppb
Chloride Limit of Detection (LOD) 0.5 ppb
Chloride Accuracy ±5% of reading or ±0.5 ppb (whichever is greater)
Sulfate Measurement Range 0 to 300 ppb
Sulfate Limit of Detection (LOD) 1.0 ppb
Sulfate Accuracy ±10% of reading or ±1.0 ppb (whichever is greater)
Measurement Cycle Time 45 minutes typical (programmable from 15 minutes to 1 hour)
Sample Flow Rate 25 to 50 mL/min
Sample Temperature Range 10 to 45 °C (50 to 113 °F)
Sample Inlet Pressure 0.3 to 7 bar (5 to 100 psig)
Grab Sample Capacity 100 mL integrated sample chamber
Process Connections Inlet: 1/4″ or 6 mm OD stainless steel compression fitting; Drain: 19 × 25.4 mm (3/4″ × 1″) hose, 2 m (6 ft) included
Main Power Supply Input 100 to 240 VAC, 50/60 Hz, 100 W typical (Max 20 A external circuit breaker required)
Analog Outputs 8 powered 0/4–20 mA outputs, 22 mA fault alarm, 500 Ω max load (not for externally powered loops)
Analog Output Accuracy & Scaling ±0.05 mA; Linear, bi-linear, logarithmic (1–4 decades), auto-ranging
Relay Outputs 4 Mechanical contacts rated 250 VAC, 3 A (Relay 1 NC; Relays 2–4 NO); 4 Reed SPDT contacts rated 250 VAC/DC, 0.5 A (Relays 5–8)
Operator Interface M800CS Color Touchscreen with simultaneous ion concentration display and trendlines
Ambient Operating Temperature 10 to 35 °C (50 to 95 °F)
Relative Humidity 10% to 70% non-condensing
Enclosure Ingress Protection IP66 / NEMA 4X (Transmitter Electronics); IP55 (Main Analyzer Enclosure)
Dimensions (H × W × D) 927 × 508 × 305 mm (36.5″ × 20.9″ × 12.0″)
Net Weight 44 kg (97 lbs)
Certifications & Compliance CE Compliant, cULus Listed (UL / Canadian Standards), ISO 9001 Manufacturing

Applications

  • Marine Steam Turbine Propulsion Plants: Continuous steam quality monitoring at the main turbine inlet to prevent chloride-induced pitting and corrosion fatigue on rotor stages.
  • Condensate Polisher Effluent Monitoring: Early detection of seawater condenser tube weeping and sulfonated cation resin exhaustion or breakthrough.
  • Marine Auxiliary & Utility Boiler Feedwater: Real-time verification of feedwater purity prior to economizer entry, enabling automated surface or bottom blowdown initiation.
  • Makeup Water & Desalination Distillate Verification: Quality assurance of reverse osmosis (RO) permeate and multi-stage flash (MSF) evaporator distillate before entering boiler reserve feed tanks.
  • Combined-Cycle & HRSG Power Generation: Cycle chemistry compliance tracking to satisfy OEM steam turbine warranty limits.

 

Compatible Equipment & System Integration

  • Transmitter Platform: Fully integrated with the Mettler Toledo Thornton M800CS multi-parameter touchscreen transmitter architecture.
  • Sample Conditioning Systems: Directly compatible with standard 1/4″ or 6 mm OD stainless steel sample conditioning panels (pressure reducers, back-pressure regulators, and cation resin columns).
  • Control Systems: Compatible with marine automation systems (Kongsberg, Wärtsilä, Praxis) and industrial DCS/PLC platforms (Allen-Bradley, Siemens, Emerson) accepting active 4–20 mA inputs.

 

Frequently Asked Questions

What is the difference between the Mettler Toledo 3000CS (58044001) and cation conductivity analyzers?

Cation conductivity measures total ionic conductivity after passing a sample through a hydrogen-form cation resin column, which cannot distinguish between harmless carbon dioxide/organic acids and corrosive chloride or sulfate ions. The 3000CS uses microcapillary electrophoresis to directly separate and quantify individual chloride (down to 0.5 ppb) and sulfate (down to 1 ppb) concentrations without interference from treatment amines or dissolved O2.

Are the 4–20 mA analog outputs on the 3000CS active or loop-powered?

The eight 0/4–20 mA analog outputs on the M800CS transmitter are internally powered (active) and support a maximum loop impedance of 500 ohms. Do not wire them to externally powered PLC/DCS analog input terminals, as doing so will damage the output circuitry.

What reagents and consumables are required to start up a new 3000CS analyzer?

The base unit (MPN: 58044001) ships without chemical reagents. To commission the analyzer, you must order the Required Startup Kit (MPN: 58091400), which supplies the internal standard, background electrolyte, microcapillary separation cartridge, and calibration standard for roughly two months of continuous operation.

Can the 3000CS measure manual grab samples from other boiler or feedwater points?

Yes. The analyzer includes an integrated 100 mL grab sample chamber that allows operators to test offline water samples from auxiliary boilers, reserve feed tanks, or condensate drains directly on the unit.

What sample temperature and pressure are required at the 3000CS inlet?

The sample stream entering the 1/4″ or 6 mm stainless steel compression fitting must be conditioned to a temperature between 10 °C and 45 °C (50 °F to 113 °F), a pressure between 0.3 and 7 bar (5 to 100 psig), and a flow rate of 25 to 50 mL/min.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.