Autronica Omicron HHL-8903 Standard Level Sensor

The Autronica Omicron HHL-8903 is a dual-point, float-operated marine level switch engineered for independent high-level and overfill (high-high) cargo tank alarm monitoring. Operating on a permanent magnet and reed switch principle, the sensor houses two electrically independent detection circuits inside a full stainless-steel assembly.

Because the deck-mounted sensor contains zero active electronic components, it withstands harsh open-deck marine environments, tank washing machine jets, high cargo temperatures, elevated tank pressures, and viscous or sticky liquid cargoes without calibration drift. When integrated into the Autronica OAS-5 / OAS 5.5 Level Alarm System, the HHL-8903 satisfies international maritime rules requiring two independent alarm circuits (typically configured for 95% High Level and 98% Overfill / High-High Level) from a single deck penetration.

 

Model Details

  • Manufacturer: Autronica Fire and Security AS (Tønsberg, Norway)
  • Product Line: Omicron Maritime Tank Instrumentation
  • Model Designation: Omicron HHL-8903 (Standard Dual-Level Sensor)
  • Primary MPN: HHL-8903 / OMICRON HHL-8903
  • System Architecture: Dual-point level switch for OAS-5 / OAS 5.5 High Level & Overfill Alarm Systems

 

Features

  1. Dual Independent Alarm Circuits: Combines High Level (HL) and High-High / Overfill (HHL) switching inside one stainless-steel stem, approved as two independent systems under IMO and classification society tanker regulations.
  2. Fail-Safe Reed Switch Mechanics: Permanent magnet float actuation maintains normally closed (NC) dry contacts under standard non-alarm operating conditions; rising cargo or a broken loop immediately opens the circuit to trigger an alarm.
  3. Zero Active Deck Electronics: Passive electro-mechanical design eliminates printed circuit boards in the hazardous cargo deck zone, cutting failure points from vibration, moisture, and salt spray.
  4. Integrated Top Lifting Test Knob: Built-in mechanical test knob on the upper connection housing allows crew members to manually lift the float assembly and verify full end-to-end loop integrity—from deck switch to bridge/cargo control room alarm panel—prior to cargo loading.
  5. Full Stainless-Steel Tank-Washing-Approved Build: Engineered to survive direct impingement from fixed tank cleaning machines while maintaining consistent alarm trip points across varying cargo specific gravities and sticky media.

 

Technical Details

Parameter Specification
Manufacturer Autronica Fire and Security AS
Series / Model Omicron HHL-8903 (Standard Dual-Point Level Sensor)
MPN HHL-8903 / OMICRON HHL-8903
Sensing Principle Float-type permanent magnet and reed switch
Detection Points 2 (High Level and High-High / Overfill)
Normal Contact Position Normally Closed (NC), fail-to-safe operation
Hazardous Area Interface Intrinsically safe passive loops (powered via OAS-5 Ex Alarm Unit AU1 / AU1.1)
Active Deck Electronics None
Construction Material Full stainless steel
Enclosure Rating IP68 (10 m water gauge), DNV Location Class D
Vibration Class DNV Location Class B
Manual Functional Test Integrated lifting knob on top connection housing
Tank Cleaning Compatibility Approved for tank washing machines
Compatible Alarm System Autronica OAS-5 / OAS 5.5 Level Alarm System

 

Compatibility

  • Alarm Systems: Autronica OAS-5 and OAS 5.5 Level Alarm Systems
  • Ex Interface Modules: Autronica AU1 and AU1.1 Ex Alarm Units
  • Common Alarm Modules: Autronica CU2 Common Alarm Unit
  • Operator Panels: Autronica Omicron OAM Alarm Panel (cabinet- or console-mounted)
  • Cabinet Power Supplies: PULS ML70.100 and PULS ML10.100

 

Applications

  • Independent High-Level (95%) and Overfill / High-High (98%) cargo tank protection on crude oil tankers (VLCC, Suezmax, Aframax)
  • Parcel and chemical tanker cargo tanks handling aggressive, high-temperature, or sticky/viscous liquid cargoes
  • Product tankers (PT) and coastal fuel carriers requiring IMO-compliant dual-point overfill alarms
  • Slop tanks, ballast tanks, and auxiliary liquid storage tanks requiring IP68 deck-mounted level switches
  • Retrofit and replacement spares for existing Autronica OAS-5 / OAS 5.5 cargo control installations

 

Frequently Asked Questions

What is the difference between the Autronica HL-8903 and the HHL-8903?

The HL-8903 is a single-point level switch designed for one alarm level (either High Level or Overfill), whereas the HHL-8903 is a dual-point level sensor featuring two electrically independent reed switch circuits inside one stainless-steel stem to monitor both High Level (typically 95%) and Overfill / High-High Level (typically 98%) simultaneously.

Does the Autronica Omicron HHL-8903 require calibration for different cargo densities?

No. The float and permanent-magnet reed switch geometry is engineered to maintain the same alarm trip point across varying liquid cargo densities, allowing tankers to switch between light distillates, chemicals, and heavier oils without recalibrating the sensor.

How do I test the HHL-8903 level sensor before cargo loading?

The HHL-8903 includes a built-in mechanical lifting knob on top of the deck connection housing. Pulling the test knob manually raises the internal float mechanism, opening the normally closed reed switches and testing the entire alarm chain—from the deck sensor through the Ex alarm cabinet to the cargo control room panel, deck horn, and beacon.

Is the HHL-8903 safe to leave installed during tank cleaning operations?

Yes. The HHL-8903 is constructed completely in stainless steel and is specifically approved for exposure to fixed tank washing machines, making it suitable for routine crude oil washing (COW) and hot-water chemical tank cleaning.

Does the HHL-8903 contain active electronic components on the cargo deck?

No. The deck-mounted sensor is purely electro-mechanical (permanent magnet and reed switch). All active signal monitoring, power supplies, and alarm logic reside inside the safe-area OAS-5 alarm cabinet.

Can the standard HHL-8903 be used on LNG or LPG gas carriers?

While the standard HHL-8903 is built for oil, chemical, and product tankers, liquefied gas carriers require the dedicated cryogenic/gas variants—specifically the HHL-8903 LPG, HHL-8903A LNG, or H-HHL-8903-LNG—which are engineered for low-temperature liquefied gas service.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.