General Monitors IR4000S Single-Point Gas Monitor 32563-1

$2,499.00

Condition: New

Country of Origin: United States

Live Support

1 in stock

  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

General Monitors IR4000S Single-Point Gas Monitor (P/N 32563-1)

The General Monitors IR4000S (MPN: 32563-1) is an explosion-proof single-point display and local user interface engineered for fixed hydrocarbon gas detection in hazardous marine, offshore, and petrochemical environments. Operating on a 20–36 VDC supply, the unit processes signals locally from a single point infrared (IR) combustible gas detector—specifically the General Monitors Model IR400 or Model IR2100—and displays real-time gas concentrations in % LEL on a high-visibility 3-digit LED readout.

The IR4000S houses all signal conditioning, diagnostic fault monitoring, and optional 8 A alarm/warn/fault relay outputs inside a rugged IP66 / NEMA Type 4X flameproof enclosure. A non-intrusive Hall-effect magnetic switch interface allows engineers to run zeroing, gas checks (bump tests), calibration, and relay resets without declassifying the hazardous area or opening the flameproof cover. Because MSA Safety has discontinued the IR4000S platform in favor of the S5000 series, genuine 32563-1 units remain critical drop-in replacements for maintaining legacy Fire & Gas (F&G) loops without re-engineering mounting footprints or PLC wiring.

 

Model Details

  • Manufacturer: General Monitors (an MSA Safety company)
  • Model Series: IR4000S Single-Point Combustible Gas Monitor
  • Manufacturer Part Number (MPN): 32563-1
  • Standard Configuration Code: IR4000S-0-0-00-1-0-1
  • Lifecycle Status: Discontinued by OEM (Active aftermarket/surplus spare for existing installations)

 

Features

  1. Local 3-Digit LED & Status Annunciation: Displays live combustible gas readings (0–100% LEL), calibration prompts, and alphanumeric diagnostic fault codes (such as bF6 for low supply voltage), paired with dedicated red Alarm and Warn LEDs.
  2. Non-Intrusive Magnetic Calibration Interface: External magnet activation at the front-panel logo grants full menu access for zeroing, gas checking, span calibration, and latching relay resets—eliminating hot-work permits during routine maintenance.
  3. Flexible Analog & Digital Output Architecture: Transmits a standard 0–21.7 mA (4–20 mA) analog loop signal alongside pass-through RS-485 Modbus RTU communications for direct integration into vessel F&G panels, DCS, and SCADA architectures.
  4. Heavy-Duty Optional 8 A Relays: Supports optional SPDT relays for Alarm, Warn, and Fault states rated at 8 A @ 250 VAC / 8 A @ 30 VDC, user-configurable for energized/de-energized and latching/non-latching logic.
  5. Four-Port Flameproof Enclosure: Built to IP66 / Type 4X environmental standards with four conduit entries, enabling either direct mechanical attachment of an IR400 detector or remote eye-level mounting away from high-vibration or overhead leak zones.

 

Technical Specifications — General Monitors IR4000S (P/N 32563-1)

Specification Category Parameter Technical Value
Identification Manufacturer / Brand General Monitors (MSA Safety)
Identification Model / MPN IR4000S / 32563-1 (Config: IR4000S-0-0-00-1-0-1)
Electrical Operating Voltage +24 VDC nominal (20 to 36 VDC range)
Electrical Power Consumption 83 mA max (2.0 W max monitor only)
Electrical Low-Voltage Fault Code bF6 at or below 18 VDC
Outputs Analog Output 0–21.7 mA (4–20 mA linear 0–100% LEL at TB2 Pin 1)
Outputs Digital Communication Single RS-485 Modbus RTU pass-through (HART optional)
Outputs Relay Ratings (Optional) Alarm, Warn, Fault — 8 A @ 250 VAC / 8 A @ 30 VDC
Wiring Terminal Wire Capacity Push blocks: 14–24 AWG; Screw blocks: 12–28 AWG
Interface Display & Controls 3-digit LED (% LEL & fault codes), Alarm/Warn LEDs, Magnetic Switch
Compatibility Supported Detectors General Monitors Model IR400 and Model IR2100 Point IR Detectors
Environmental Operating Temperature -40°C to +75°C (-40°F to +167°F)
Environmental Storage Temperature -50°C to +85°C (-58°F to +185°F)
Environmental Humidity 5% to 100% RH, non-condensing
Mechanical Enclosure & Ingress Protection Explosion-Proof Aluminum (or 316 SS option), IP66 / NEMA Type 4X
Mechanical Dimensions (L × W × H) 6.5 in × 6.0 in × 3.21 in (165 mm × 152 mm × 81.5 mm)
Mechanical Weight 5.5 lbs (2.5 kg) — Aluminum enclosure
Certifications Hazardous Area Approvals Class I, Div 1 & 2, Groups B, C, D; Class I, Zone 1, IIB + H2 T5; ATEX; IECEx; FM 6310/6320; CSA 22.2 No. 152; CE; SIL 2

TB1 — Detector Interface Block (IR400 / IR2100)

  • Pin 1 (4-20 mA IN): Receives the analog measurement current loop from the connected IR400/IR2100 detector.
  • Pin 2 (CAL IN): Connects to the detector’s brown calibration line (CAL) for local zeroing, gas check, and span commands.
  • Pins 5 & 6 (IR400 MOD+ / IR400 MOD-): Connects the detector’s RS-485 Modbus data lines into the monitor’s pass-through bus.
  • Pin 7 (COM): 0 VDC power supply common to the detector.
  • Pins 8 & 9 (+24V): +24 VDC power distribution terminals feeding the connected point detector.

 

TB2 — Host / Control Room Interface Block

  • Pin 1 (4-20 mA OUT): Transmits the conditioned 4–20 mA analog loop to the vessel’s F&G PLC, DCS, or trip amplifier.
  • Modbus Pass-Through (MOD+ / MOD-): Passes unchanged RS-485 Modbus RTU telemetry from the attached IR detector to the host control system.
  • Pin 7 (Remote Reset): Accepts a dry, normally open (N.O.) external momentary switch to remotely reset latched Alarm and Warn relays without using the front-panel magnet.
  • Power Input (+24 VDC & COM): Main 20–36 VDC supply input from the F&G power distribution board.

 

TB3 — Relay Output Block (Optional Relay Configurations)

  • Provides dedicated Form-C (NO / NC / COM) contacts for ALARM, WARN, and FAULT conditions.
  • Relay coils are user-selectable via menu configuration for Energized (Fail-Safe) or De-Energized normal states, and Latching or Non-Latching action.

 

Compatibility

  • Directly Supported Point IR Detectors:
    • General Monitors Model IR400 Infrared Point Combustible Gas Detector (e.g., P/N 32500, 32500-1)
    • General Monitors Model IR2100 Infrared Point Detector
  • System & Control Integration:
    • Compatible with industrial 24 VDC Fire & Gas (F&G) panels, PLC analog input cards (4–20 mA), DCS marshalling cabinets, and RS-485 Modbus RTU master controllers.
    • Note on Gas Compatibility: When paired with the IR400, the system detects hydrocarbon combustible gases and vapors (0–100% LEL methane and higher hydrocarbons). Infrared point detectors cannot detect Hydrogen (H2).

 

Part Number Cross-References

  • Primary MPN: 32563-1 (Config: IR4000S-0-0-00-1-0-1)
  • Related IR4000S Variant P/Ns: 32563, 32563-2, 32563-3 (differ by enclosure material, conduit entry threading, or relay/approval options)
  • Multi-Point Series Counterpart: General Monitors IR4000M (P/N 32580 — monitors up to 8 remote IR400 detectors)
  • Paired Detector Assemblies: General Monitors IR400 (32500, 32500-1)
  • OEM Modern Replacement: MSA S5000 Gas Monitor (recommended by MSA Safety for new builds or full panel retrofits)

 

Applications

  • FPSOs, FSOs & Offshore Oil Platforms: Wellhead modules, separator skids, gas compression decks, and mud-logging areas.
  • LNG, LPG & Chemical Tankers: Cargo compressor rooms, deck pipe racks, and gas-fuelled engine room enclosures (IGF Code spaces).
  • Refineries & Petrochemical Plants: Tank farms, loading gantries, alkylation units, and process manifolds.
  • Gas Turbines & Compressor Stations: Enclosure ventilation ducts and fuel gas skids.
  • Pipeline Metering & Wastewater Facilities: Digester gas monitoring and hydrocarbon transfer stations.

 

Frequently Asked Questions

What gas detectors are compatible with the General Monitors IR4000S 32563-1?

The IR4000S (32563-1) is engineered to operate with General Monitors point infrared (IR) combustible hydrocarbon gas detectors, specifically the Model IR400 and Model IR2100. It can either be close-coupled directly to the detector via its conduit ports or mounted remotely at eye level for easier maintenance access.

Can the IR4000S monitor detect Hydrogen (H2) gas?

No. The IR4000S serves as the display, relay, and user interface for infrared point detectors (IR400/IR2100), and infrared absorption technology cannot detect hydrogen gas. For hydrogen monitoring, a catalytic bead or ultrasonic gas detection system is required.

How do I calibrate or bump-test the IR4000S without opening the explosion-proof housing?

The IR4000S features a non-intrusive magnetic switch located behind the front-panel logo. Placing a calibration magnet on the logo accesses the main menu to initiate zeroing, gas check (bump test), span calibration, or latching relay resets while maintaining full Class I, Division 1 / Zone 1 flameproof integrity.

What does fault code bF6 mean on the IR4000S LED display?

Fault code bF6 indicates a low supply voltage condition where the DC input at the monitor’s power terminals has dropped to or below 18 VDC. Check the 24 VDC power supply output, inspect terminal connections for corrosion, and verify that cable gauge and run length are not causing excessive voltage drop.

Is the General Monitors IR4000S 32563-1 still in production, or is there an OEM replacement?

MSA Safety has discontinued new factory production of the IR4000S series and designates the MSA S5000 Gas Monitor as its current-generation replacement. However, New Old Stock (NOS), surplus, and bench-tested reconditioned 32563-1 units remain available as direct plug-and-play spares to maintain existing marine and industrial F&G installations without panel modifications.

What are the relay contact ratings on the IR4000S?

On relay-equipped configurations, the IR4000S provides three Form-C relays for Alarm, Warn, and Fault outputs rated at 8 Amps at 250 VAC or 8 Amps at 30 VDC. Each relay can be configured for energized or de-energized normal operation and latching or non-latching behavior.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.