ABB SACE Tmax T6N 1SDA060202R1 630A 3-Pole MCCB

$1,869.00

Condition: New

Country of Origin: Italy

Live Support

1 in stock

  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

ABB SACE Tmax T6N 1SDA060202R1 / AL04134464 630A 3-Pole Circuit Breaker

The ABB SACE Tmax T6N (1SDA060202R1) is a 3-pole Moulded Case Circuit Breaker (MCCB) built for primary power distribution, feeder protection, and heavy motor circuits. Rated for a continuous uninterrupted current of 630A, this frame-size T6 breaker pairs a high 1000V insulation rating with a compact 210 mm width. It uses an adjustable TMA thermomagnetic trip unit that lets engineers fine-tune both thermal overload and magnetic short-circuit thresholds directly on the front face.

 

Model Details

  • Manufacturer Part Number (MPN): 1SDA060202R1
  • Alternate / Cross Reference Number: AL04134464
  • Extended Model Designation: T6N 630 TMA 630-6300 3p F F
  • EAN / GTIN: 8015644626600
  • Frame Size & Performance Level: T6 Frame, Level N (Normal breaking capacity: 36 kA at 380–415V AC)
  • Mounting & Terminal Version: Fixed Execution (F) with Front Terminals (F) on top and bottom
  • Country of Origin: Italy
  • Customs Tariff / HSN Code: 85362090

 

Technical Specifications

Parameter Specification
Manufacturer ABB (SACE Tmax T Series)
Manufacturer Part Number (MPN) 1SDA060202R1
Cross-Reference / Alternate ID AL04134464
Extended Type Designation T6N 630 TMA 630-6300 3p F F
EAN / GTIN 8015644626600
Number of Poles 3-Pole (3P)
Rated Uninterrupted Current (Iu) 630 A
Rated Operational Voltage (Ue) 690 V AC (50/60 Hz) / 750 V DC
Rated Insulation Voltage (Ui) 1000 V
Rated Impulse Withstand Voltage (Uimp) 8 kV
Trip Release Type TMA (Thermomagnetic, Adjustable)
Magnetic Trip Range (I3) 3150 A to 6300 A (5x to 10x In)
Ultimate Breaking Capacity (Icu) – AC 70 kA (220/230V), 36 kA (380/400/415V), 30 kA (440V), 25 kA (500V), 20 kA (690V)
Service Breaking Capacity (Ics) – AC 70 kA (220/230V), 36 kA (380/400/415V), 30 kA (440V), 25 kA (500V), 15 kA (690V)
Ultimate Breaking Capacity (Icu) – DC 36 kA (250V DC, 2 poles in series), 25 kA (500V DC, 2 poles in series), 16 kA (750V DC, 3 poles in series)
Rated Short-Time Withstand Current (Icw) 7.6 kA for 1 s
Power Loss per Pole 30.6 W (at rated operating conditions)
Terminal Configuration Fixed Front Terminals (F F)
Mechanical Durability 20,000 cycles (120 cycles/hour)
Electrical Durability 7,000 cycles (60 cycles/hour)
Net Dimensions (W x H x D) 210 mm x 268 mm x 103.5 mm
Net Weight 8.987 kg (Gross packaged weight: 11 kg)
Reference Standard IEC 60947-2

 

Features

  1. Dual AC and DC Voltage Ratings: Rated up to 690 V AC and 750 V DC, allowing deployment across standard 415V/440V marine switchboards, 690V industrial grids, and multi-pole series DC distribution buses.
  2. Adjustable TMA Thermomagnetic Protection: Lets operators dial in exact overload protection and set instantaneous magnetic tripping between 3150 A and 6300 A to prevent nuisance trips during high-inrush equipment startups.
  3. Compact 103.5 mm Depth: Shares the exact 103.5 mm installation depth of smaller T4 and T5 frames, simplifying panel upgrades without requiring deeper enclosures.
  4. Modular Tmax Accessory Compatibility: Accepts common Tmax T4–T6 internal and external accessories, letting technicians share spare shunt trips, undervoltage releases, and auxiliary contacts across multiple breaker sizes.

 

Applications

  • Main and sub-distribution switchboards on commercial vessels, offshore platforms, and shipyards.
  • Marine auxiliary engine room panels, ballast pump feeders, and thruster control cubicles.
  • Industrial manufacturing power distribution centers and main incoming feeder panels.
  • Heavy-duty motor control centers (MCCs) and step-down transformer secondary protection.
  • High-capacity DC battery banks, rectifiers, and solar/energy storage combiner circuits (up to 750 V DC).

 

Compatibility

  • Line & Load Terminal Allocation: Top terminals (1/L1, 3/L2, 5/L3) and bottom terminals (2/T1, 4/T2, 6/T3) come factory-fitted with Front (F) flat copper connection bars designed for bolted busbars or compression cable lugs. Because the TMA trip unit is non-polarized, reverse-feeding (bottom-to-top) is permissible without derating.
  • DC Series Wiring: For 250 V DC or 500 V DC circuits, wire 2 poles in series; for 750 V DC circuits, wire all 3 poles in series to achieve full arc-quenching capacity.
  • Compatible ABB Tmax Accessories:
    • Internal Service Releases: SOR (Shunt Opening Release) and UVR (Undervoltage Release) shared across Tmax T4, T5, and T6 frames.
    • Auxiliary Contacts: AUX-C (1Q + 1SY or 3Q + 1SY pre-wired changeover contacts).
    • Mechanical & Operating Mechanisms: Direct rotary handle (RHD), transmitted rotary handle (RHE), stored-energy motor operator (MOE), and mechanical interlock plates (MIR).
    • Terminal Conversion Kits: Compatible with ABB Extended Front (EF), Extended Spread (ES), Rear (R), and High-Capacity Cable Clamp (FC CuAl) conversion kits.

 

Part Number Cross-References

  • ABB Primary Order Code: 1SDA060202R1
  • Alternate Catalog / Stock Reference: AL04134464
  • ABB Short Description: T6N 630 TMA 630-6300 3p F F
  • Same-Frame / Higher Breaking Capacity Variants:
  • 1SDA060204R1 – T6S 630 TMA 630-6300 3p F F (50 kA at 415V AC)
  • 1SDA060210R1 – T6N 630 TMA 630-6300 4p F F (4-Pole version, 36 kA at 415V AC)

 

Frequently Asked Questions

What is the difference between ABB 1SDA060202R1 and AL04134464?

Both numbers refer to the exact same 3-pole, 630A ABB SACE Tmax T6N circuit breaker with a TMA thermomagnetic trip unit and fixed front terminals. 1SDA060202R1 is ABB’s global manufacturing order code, while AL04134464 is an alternate industrial catalog and marine supply cross-reference number.

Can the ABB T6N 630A circuit breaker be used on DC electrical systems?

Yes. The ABB Tmax T6N 630 is rated up to 750 V DC under IEC 60947-2. To achieve full short-circuit breaking capacity, you must wire 2 poles in series for 250 V DC (36 kA) or 500 V DC (25 kA), and all 3 poles in series for 750 V DC (16 kA).

Is the ABB SACE Tmax T6N approved for marine shipboard installation?

Yes. The Tmax T6 series holds Germanischer Lloyd (GL) marine type approval (1SDL000163R0057) and complies with IEC 60947-2, making it suitable for commercial vessels, offshore rigs, and marine distribution panels.

What are the exact cutout and mounting dimensions of the T6N 630?

The breaker measures 210 mm wide by 268 mm high by 103.5 mm deep and weighs approximately 8.99 kg. Its 103.5 mm depth matches the T4 and T5 frames, allowing direct mounting on standard Tmax DIN plates or switchgear mounting pans.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.