Chris-Marine LEMAG ECI Electronic Cylinder Pressure Indicator & Peak Pressure Analyzer

The Chris-Marine LEMAG ECI is a portable, electronic cylinder pressure indicator built for real-time combustion diagnostics, peak firing pressure verification, and cylinder load balancing on large 2-stroke and 4-stroke internal combustion engines. Designed to replace mechanical peak pressure gauges and drum indicators in engine rooms and stationary power plants, the unit captures high-frequency cylinder pressure curves via a leak-proof piezoelectric transducer mounted directly onto standard indicator valves.

The LEMAG ECI computes Mean Indicated Pressure (MIP), indicated cylinder power (kW/ihp), compression pressure, ignition timing, and misfire percentages on-site. The handheld terminal features a high-contrast color LCD and tactile membrane keys engineered for gloved operation, transferring logged engine files over USB to the bundled LEMAG ECI PC evaluation software for ISO-corrected trend analysis and superintendent reporting.

 

Model Details

  • Standard Configuration — LEMAG ECI (MPN: R-ECI_00001 | Doc Ref: H054-1840/E): Equipped with the handheld analyzer, single leak-proof piezoelectric pressure sensor, protective transport case, USB data/charging cable, and PC evaluation software. Uses algorithmic Top Dead Center (TDC) detection for pressure-vs-time and calculated pressure-vs-crank-angle diagnostics.
  • Crank-Angle Configuration — LEMAG ECI-MS (MPN: R-ECI_00002): Adds a dual-input handheld interface, high-resolution inductive MS Crank Angle Sensor (CAS), toothed/magnetic belt drive, and engine-side junction box. Eliminates torsional vibration errors on low-speed 2-stroke crosshead engines by measuring true crank angle to better than 1° accuracy.

 

Technical Specifications — Chris-Marine LEMAG ECI

Specification Parameter Technical Value / Rating
Manufacturer / Brand Chris-Marine AB / LEMAG
Model & Manufacturer Part Numbers (MPN) LEMAG ECI (R-ECI_00001) / LEMAG ECI-MS (R-ECI_00002)
Pressure Measuring Range 0 – 350 bar (0 – 250 bar on early series)
Measurement Accuracy < ±1% Full Scale
Pressure Transducer Type Piezoelectric, leak-proof thermally isolated design
Sensor Operating Temperature Range -50°C to +400°C (continuous operation rated)
Engine Speed Range 30 – 2,000 RPM (2-stroke and 4-stroke engines)
Crank Angle Resolution (ECI-MS Only) < 1° crank angle accuracy (inductive CAS with belt for shafts up to Ø900 mm)
Engine & Cylinder Capacity Up to 20 cylinders per engine; memory for 8 engine profiles
Input / Output & Terminal Allocations Input 1: Piezoelectric Pressure Sensor | Input 2 (ECI-MS): MS Crank Angle Sensor / Junction Box | I/O: USB Port (PC Data Sync, Configuration & Battery Charging)
Display Type & Dimensions Color Graphic LCD, 97 mm (W) × 55 mm (H) / 3.8″ × 2.2″
Power Supply & Battery Runtime Internal rechargeable battery; minimum 4 hours continuous runtime; USB charging circuit
Handheld Unit Dimensions (W × H × D) 260 mm × 150 mm × 55 mm (10.2″ × 5.9″ × 2.2″)
Net & Gross Weight Handheld Unit: 1.4 kg | Complete Kit with Carrying Case: 6.9 kg
Diagnostic & Software Functions Peak Pressure (Pmax), Pcomp, MIP, Indicated Power, p/α, p/V, p/t, dp/dα, Cylinder Parade, Misfiring Analysis, Live Balancing, ISO-Correction
Recommended Calibration Interval Every 12 – 24 months (Chris-Marine Germany GmbH)

Engine & Mechanical Compatibility

  • Engine Operating Cycles: All 2-stroke crosshead and 4-stroke trunk-piston internal combustion engines equipped with standard indicator cocks/valves.
  • Fuel Compatibility: Heavy Fuel Oil (HFO), Marine Diesel Oil (MDO), Marine Gas Oil (MGO), Liquefied Petroleum Gas (LPG), Natural Gas, and dual-fuel engines.
  • Compatible Marine & Stationary Engine OEMs: MAN Energy Solutions (B&W MC/ME/LGIM/LGIP series), WinGD / Wärtsilä (RT-flex, X-series, W20–W46, W31, W34DF, W50DF), Caterpillar / MaK (M20, M25, M32, M43, 3500/3600 series), Yanmar, Daihatsu, Himsen (Hyundai), Bergen, Sulzer, and Pielstick.
  • Crank Angle Sensor Fitment (ECI-MS): Fits exposed intermediate or flywheel shafts up to 900 mm via the supplied tension belt and inductive pick-up assembly.

 

Part Number Cross-References

  • Chris-Marine / LEMAG MPNs: R-ECI_00001 (LEMAG ECI 350 bar), R-ECI_00002 (LEMAG ECI-MS 350 bar), Brochure/Spec Doc H054-1840/E.
  • Functional Equivalents & Predecessors:
  • LEMAG PREMET X / PREMET XL / PREMET C (Legacy LEMAG electronic indicators eligible for Chris-Marine ECI trade-in programs).
  • LEMAG PEAKmag & LEMAG LS
  • Kistler Type 2516B12 / MarPrime / Imes EPM-XP (Comparable shipboard portable cylinder pressure analyzers).

 

Features

  1. Automatic Sensor Recognition & Glove-Ready UI: Handheld terminal automatically identifies connected pressure and crank-angle sensors and guides engineers through step-by-step graphic menus operable with thick engine-room gloves.
  2. Cylinder Parade & Live Balancing Mode: Automatically aligns combustion curves by engine firing order and firing angle, letting engineers verify fuel rack or VIT adjustments immediately.
  3. PC Trend Analysis & ISO Correction: Transfers stored engine data via USB to the included PC software for ISO ambient condition correction, baseline comparison, and fleet superintendent reporting.

 

Frequently Asked Questions

What is the difference between the LEMAG ECI and the LEMAG ECI-MS?

The standard LEMAG ECI (R-ECI_00001) uses a single pressure sensor input and calculates Top Dead Center (TDC) algorithmically from the compression curve, making it well-suited for 4-stroke auxiliary engines and routine peak pressure checks. The LEMAG ECI-MS (R-ECI_00002) adds a second sensor port for an inductive Crank Angle Sensor (CAS) and shaft belt, measuring crank angle to better than 1° accuracy to eliminate torsional vibration errors on low-speed 2-stroke main engines.

Can the LEMAG ECI be used on gas and dual-fuel marine engines?

Yes. The LEMAG ECI supports all 2-stroke and 4-stroke engines operating between 30 and 2,000 RPM on Heavy Fuel Oil (HFO), Marine Diesel Oil (MDO), Natural Gas, and LPG, provided the cylinder head is fitted with a standard indicator valve.

How often does the Chris-Marine LEMAG ECI require calibration?

Chris-Marine recommends sending the handheld unit and pressure sensor to Chris-Marine Germany every 12 to 24 months for linearity testing, calibration, and issuance of a renewed calibration certificate.

How long does the battery last during engine room rounds?

A fully charged LEMAG ECI handheld unit provides a minimum of 4 hours of continuous operation. Inserting the USB cable automatically initiates battery charging while also enabling PC remote administration and data transfer.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.