Emerson Damcos MAS 2600 G30-48-0/0P Tank Level Transmitter

$999.00

Condition: New

Live Support

1 in stock

  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

Emerson Damcos MAS 2600 G30-48-0/0P Tank Level Transmitter

The Emerson Damcos MAS 2600 G30-48-0/0P is a 2-wire, loop-powered 4–20 mA DC hydrostatic tank contents transmitter engineered for continuous liquid level measurement in marine, offshore, and hazardous cargo environments. Designed by Damcos A/S (part of Emerson Automation Solutions), the unit converts hydrostatic head pressure into a proportional analog current signal.

The sensing element is a pressure-sensitive silicon micro strain gauge mounted in a glass-to-metal seal. It sits behind an electron-beam-welded, oil-filled titanium isolation diaphragm housed inside a fully welded titanium body (IP68). The G30-48-0/0P variant combines a 0–16.0 mH₂O (1.5 bar g) gauge transducer without an internal Pt100 sensor, a 48-meter standard vented 6-core marine cable, bare transducer ends (no mechanical mounting fittings), and a programmable amplifier module (P). Because the gauge transducer references atmospheric pressure through an internal capillary breather tube integrated into the interconnecting cable, it automatically compensates for ambient barometric fluctuations inside dry, pressure-neutral spaces.

 

Model Details

  • Manufacturer: Emerson Process Management / Damcos A/S
  • Series: MAS 2600 Tank Contents Transmitter
  • Manufacturer Part Number (MPN): MAS 2600 G30-48-0/0P (also written as MAS 2600-G30-48-0/0P)

 

Compatibility

  • Tank Gauging & Valve Remote Control Systems: Emerson Damcos Tank Management Systems, Damcos View, Damcos Ethernet Controllers, and legacy Danfoss Marine Systems (DMS) / Marine Automation Denmark (MAD) cargo & ballast consoles.
  • Calibration & Test Gear: Druck / GE DPI 802P pressure calibrator, PV210 hand pump, Damcos Test Cup (G022S100), and vacuum calibration manifold.
  • PLC / DCS Analog Input Cards: Any standard marine type-approved 4–20 mA passive or active analog input module.

 

Features

  1. Full Titanium Wetted Construction: Electron-beam-welded titanium housing (Ø 25 mm x 193 mm) and titanium diaphragm resist pitting and crevice corrosion in seawater, ballast water, sour crude, and aggressive chemical cargoes.
  2. 8-Step Field-Programmable Span: The P programmable amplifier divides the 0–16.0 mH₂O transducer into 8 selectable sub-ranges (0.50–0.75 mH₂O up to 10.00–16.00 mH₂O), letting engineers match the 20 mA full-scale output to exact tank and vent-pipe head heights.
  3. High Overpressure & Burst Margin: Withstands 4x nominal range (64 mH₂O / 6.0 bar) without calibration shift and 6x nominal range (96 mH₂O / 9.0 bar) burst pressure against cargo sloshing or ballast pump surges.
  4. Intrinsic Safety for Zone 0 / Zone 1 Tanks: Certified Ex ia IIC T4 / T5 (ATEX & IECEx) for direct submersion inside cargo oil, slop, and fuel tanks when wired through approved Ex barriers.
  5. Low-Smoke Halogen-Free Vented Marine Cable: Supplied with 48 meters of flame-retardant, oil- and seawater-resistant CKJPJP/SC 6-core cable featuring an integrated 1.5 x 2.5 mm breather capillary.

 

Technical Details

Parameter Specification
Manufacturer / Brand Emerson Process Management / Damcos A/S
Model / MPN MAS 2600 G30-48-0/0P
Transducer Principle Piezoresistive silicon micro strain gauge in glass-to-metal seal, oil-filled isolation
Pressure Reference Gauge (vented to atmosphere via integrated cable breather tube)
Nominal Measuring Range 0 to 16.0 mH2O (1.5 bar g nominal)
Programmable Sub-Ranges (8 Steps) Step 1: 0.50–0.75 mH2O | Step 2: 0.75–1.00 mH2O | Step 3: 1.00–1.50 mH2O | Step 4: 1.50–2.50 mH2O | Step 5: 2.50–4.00 mH2O | Step 6: 4.00–6.00 mH2O | Step 7: 6.00–10.00 mH2O | Step 8: 10.00–16.00 mH2O
Output Signal 4–20 mA DC, 2-wire loop-powered
Supply Voltage 17–33 VDC (14 VDC minimum across transmitter terminals)
Current Limiting 25 mA typical / 32 mA maximum
Static Accuracy ±0.25% F.S. at 20 °C
Long-Term Stability Max. 0.1% F.S. per year
Total Error Band (TEB) ±0.4% F.S. (0 to +50 °C) / ±2.0% F.S. (-20 to +80 °C)
Overload / Burst Pressure 4x nominal range without calibration shift / 6x nominal range burst
Built-in Temperature Sensor None (Option 0)
Wetted Materials Titanium housing and electron-beam-welded titanium diaphragm
Transducer Dimensions Diameter 25 mm x Length 193 mm
Interconnecting Cable 48 m standard vented marine cable (CKJPJP/SC 6×0.5 mm² + 1.5×2.5 mm vent tube, 150/250 V)
Operating Temperature (Safe / Ex) -20 °C to +80 °C (Transducer & standard cable); -40 °C to +85 °C (Amplifier housing)
Ingress Protection Transducer: IP68 (continuous submersion) / Amplifier Box: IP56 (seawater-resistant polyester, RAL 7000)
Hazardous Area Certification ATEX / IECEx Intrinsically Safe: Ex ia IIC T4 / T5 (DEMKO 11 ATEX 146506X / IECEx ULD 10.0013X)
Entity Parameters (IS) Umax = 33 V, Ik ≤ 45 mA, Cint = 10 nF, Lint = 20 μH
Marine Classification Approvals DNV, GL, LR (LRS), ABS, BV, RINA, NK, KR (KRS), RS (MRS), PRS, CE

Applications

  • Water Ballast & Anti-Heeling Tanks: Continuous hydrostatic sounding in double-bottom, wing, topside, and forepeak ballast tanks.
  • Cargo & Slop Tanks (Tankers / FPSOs): Intrinsically safe level gauging in crude oil, product, chemical, and slop tanks compatible with titanium.
  • Fuel Oil & Lubricating Oil Service Tanks: Monitoring Heavy Fuel Oil (HFO), Marine Gas Oil (MGO), diesel oil, and lube oil storage/settling tanks (within -20 °C to +80 °C standard cable limit).
  • Fresh Water & Technical Water Tanks: Potable water, distilled boiler feedwater, and cooling water expansion tanks.
  • Vessel Draft & Trim Monitoring: Forward, midship, and aft draft measurement via stilling/vent pipes (min. 1″ ID).

 

Part Number Cross-References

  • Emerson / Damcos Exact Configuration: MAS 2600 G30-48-0/0P / MAS 2600-G30-48-0/0P
  • Internal Pressure Capsule (Sensing Core): Druck PDCR 941-1 / PDCR 941-1102-1 (1.5 bar g silicon micro strain-gauge element)
  • Related MAS 2600 Range-3 (0–16 mH₂O) Variants (Differing in Cable Length, Mounting, or Box):
    • MAS 2600 G30-05-0/0P — 5 m standard cable, no fittings, programmable amplifier
    • MAS 2600 G30-10-0/0P — 10 m standard cable, no fittings, programmable amplifier
    • MAS 2600 G30-16-0/0P — 16 m standard cable, no fittings, programmable amplifier
    • MAS 2600 G30-35-4/1P — 35 m standard cable, DN25 flange mounting (4), PG11/PG11 amplifier box (1), programmable (P)
  • Legacy Brand Equivalents: Danfoss Marine Systems (DMS) MAS 2600 / Marine Automation Denmark (MAD) 2600 Series

 

Frequently Asked Questions

What does the model code MAS 2600 G30-48-0/0P stand for?

G indicates a gauge-pressure titanium transducer with atmospheric vent compensation, 3 denotes the 0–16.0 mH₂O (1.5 bar g) pressure capsule, 0 indicates no built-in Pt100 temperature sensor, 48 specifies a 48-meter standard vented marine cable (-20 °C to +80 °C), the second 0 means supplied without mounting fittings, and /0P denotes a programmable 8-step 4–20 mA output amplifier configuration.

Is the G30-48-0/0P suitable for heated Heavy Fuel Oil (HFO) tanks?

The standard cable on the G30-48-0/0P is rated up to +80 °C. It is suitable for MGO, diesel, and unheated fuel oil tanks, whereas heated HFO tanks exceeding +80 °C require the high-temperature H30 variant rated up to +125 °C.

How do I calibrate the 4–20 mA range on the MAS 2600 programmable amplifier?

Select one of the 8 factory-divided sub-ranges (0.50–0.75 mH₂O up to 10.00–16.00 mH₂O) using the internal range selector switch on the amplifier PCB, then fine-tune the ZERO (4 mA at atmospheric pressure) and SPAN (20 mA at target hydrostatic pressure) potentiometers using a precision pressure calibrator and test cup.

Does the MAS 2600 G30-48-0/0P include a built-in temperature sensor?

No. The 0 digit immediately following G30 confirms that this unit is manufactured without an internal Pt100 RTD sensor, leaving the white and brown cores in the 6-core cable unused.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.