Honeywell CC-PFB801 51410087-175 FIM8 Series C Module

Live Support
  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

Honeywell CC-PFB801 51410087-175 Series C FIM8 Fieldbus Interface Module 24VDC

The Honeywell CC-PFB801 (Manufacturing Part Number: 51410087-175) is a 8-channel FOUNDATION Fieldbus Interface Module (FIM8) engineered for the Honeywell Experion® Process Knowledge System (PKS) C300 architecture. Operating on an internal backplane logic rail of 24 VDC, the module acts as a high-throughput deterministic bridge between host C300 controllers and field-mounted process instrumentation across distributed industrial topologies.

Designed with G3 conformal coating to withstand harsh marine, offshore, and petrochemical atmospheres, the FIM8 manages physical layer signal decoding, token-passing schedules, Link Active Scheduler (LAS) arbitration, and cyclic/acyclic macrocycle execution across 8 independent H1 segments.

 

Model Details

  • Product Series: Experion PKS Series C I/O
  • Model Identifier: CC-PFB801
  • Manufacturer Part Number (MPN): 51410087-175
  • Module Designation: FIM8 (Fieldbus Interface Module – 8 Networks)
  • Carrier Interfacing: Series C 8-Segment Fieldbus IOTA (Input/Output Termination Assembly, e.g., CC-TFB801 / CC-TFB811)
  • Form Factor: Series C coated vertical blade with integrated heat dissipation shroud and carrier engagement latch

 

Technical Specifications

Parameter Specification / Rating
Module Model / MPN CC-PFB801 / 51410087-175
Nominal Supply Voltage 24 VDC (Operating tolerance: 18.0 VDC to 30.0 VDC via Series C Carrier)
Current Consumption 380 mA @ 24 VDC (Max Power Dissipation: Approx. 9.1 W to 12 W internal)
Fieldbus Communication Protocol FOUNDATION Fieldbus H1 (IEC 61158-2 Physical Layer)
H1 Transmission Baud Rate 31.25 kbit/s, Manchester Biphase encoded
Number of Dedicated H1 Channels 8 Channels / Networks per module (electrically isolated)
Device Node Capacity Up to 16 physical field devices per H1 network (Up to 128 devices per FIM8)
Macrocycle Timing Options 250 ms, 500 ms, 1 s, 2 s, 4 s, 8 s, 16 s, and 32 s
Channel-to-Bus Isolation 1500 VAC RMS galvanic dielectric withstand isolation
Operating Temperature Range -40°C to +70°C (-40°F to +158°F)
Storage Temperature Range -55°C to +85°C (-67°F to +185°F)
Relative Humidity 5% to 95% non-condensing
Environmental / Harsh Gas Resistance ANSI/ISA-71.04-2013 Class G3 Conformal Coated
Dimensions (H x W x D) 127 mm x 127 mm x 40 mm (Approx. 5.0 in x 5.0 in x 1.57 in)
Unit Weight 0.80 kg (1.76 lbs)

 

Applications

  • Offshore FPSO & Fixed Platform Automation: Process safety tie-ins, wellhead monitoring, multi-phase separator control, and gas dehydration skids exposed to continuous salt spray and sulfur fumes.
  • Marine Engine Room & Fuel Gas Supply Systems (FGSS): LNG/MGO bunkering skids, fuel flow monitoring, boiler pressure loops, and scrubber washwater pH control.
  • Refinery & Petrochemical Plants: Hydrocracker unit instrument multiplexing, distillation column temperature arrays, and pneumatic control valve modulation via FF positioners.
  • Specialty Chemical & Pharmaceutical Processing: Hazardous Class I, Division 2 / Zone 2 environments requiring high-integrity digital communications with diagnostic field assets.
  • Continuous Power Generation Facilities: Superheated steam valve positioning, feedwater pump telemetry, and turbine auxiliary integration.

 

Compatible System Equipment

  • Controllers: Honeywell Experion PKS C300 Controller (Series C form factor)
  • Redundant Pairs: Matched CC-PFB801 units configured in dual-redundant slots on redundant carriers
  • Termination Blocks (IOTA):
    • CC-TFB801: Non-Redundant 8-Network Fieldbus IOTA
    • CC-TFB811 / CC-TFB812: Redundant 8-Network Fieldbus IOTA
  • Power Supplies: 24VDC Series C Power Supply Modules (e.g., CC-PWRR01)
  • Field Conditioning Equipment: Pepperl+Fuchs FieldConnex®, MTL Megablock, or MooreHawke trunk/spur fieldbus power conditioners and terminators

 

Part Number Cross-References

  • Core Assembly Model: CC-PFB801
  • Factory Order / Spares Number: 51410087-175
  • Non-Coated Equivalent / Standard Variant: 51405087-175 / MC-PFB801 (Legacy or standard non-G3 assemblies)
  • Associated IOTAs: 51308373-175 (CC-TFB801 Non-Redundant IOTA), 51308375-175 (CC-TFB811 Redundant IOTA)
  • Interchangeable Revisions: Firmware revisions compatible with Experion PKS R400, R410, R430, R500, R510, and R520 platforms

 

Frequently Asked Questions

What is the primary function of the Honeywell CC-PFB801 51410087-175?

The Honeywell CC-PFB801 is an 8-channel Fieldbus Interface Module (FIM8) that connects FOUNDATION Fieldbus H1 process instrumentation (pressure, temperature, flow transmitters, and valve positioners) directly to the Honeywell Experion PKS C300 DCS controller.

Can the CC-PFB801 module be configured in a redundant setup?

Yes. The CC-PFB801 supports side-by-side redundancy when mounted on a redundant Series C carrier (IOTA CC-TFB811/CC-TFB812). In this arrangement, if the primary FIM encounters a hardware fault, the backup module seamlessly assumes bus control without dropping active field control loops.

How many field instruments can be connected to a single CC-PFB801 card?

The module features 8 separate H1 networks. Each network supports up to 16 physical field instruments, allowing a single CC-PFB801 to interface with up to 128 FOUNDATION Fieldbus devices, subject to segment power supply and macrocycle execution timing limits.

What does the G3 conformal coating on the 51410087-175 part number signify?

The G3 rating denotes that the module’s printed circuit boards have undergone an industrial conformal coating process compliant with ANSI/ISA-71.04 Class G3. This protects internal surface-mount components against airborne contaminants, humidity, sulfur dioxide, and salt spray typically found on marine vessels and chemical plants.

What is the standard operating voltage and current draw for the module?

The CC-PFB801 is powered via the Series C backplane at a nominal 24 VDC. Typical module logic current consumption is approximately 380 mA at 24 VDC. Note that field transmitters on each H1 segment require separate segment power conditioners.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.