Honeywell S702PF IR Viewing Head
Condition: New
Country of Origin: United States
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Honeywell S702PF IR Viewing Head for Flame Monitor
The Honeywell S702PF is an infrared (IR) flicker-sensitive optical viewing head engineered for continuous flame supervision in heavy fuel oil, marine propulsion/auxiliary boilers, and coal-fired combustion systems. Built with a 1.48-inch (36 mm) machined aluminum barrel housing and a factory-installed 10-foot (3-meter) shielded pigtail cable, the S702PF eliminates field connector termination failures in high-vibration engine rooms and harsh boiler fronts.
The S702PF utilizes a Germanium photodiode paired with an integrated 33 Hz high-pass flicker filter. It discriminates true turbulent combustion flame modulation from steady background infrared radiation. Electronic self-checking pulses are processed directly from the compatible Honeywell signal processor without any moving mechanical shutters.
Model Details
- Manufacturer Part Number (MPN): S702PF
- Series: Honeywell Series 700 / 800 Optical Viewing Heads
- Configuration Suffix Breakdown:
- S702: Series 700 Aluminum Body, Germanium IR Sensor, Standard 33 Hz High-Pass Filter
- PF: Factory-installed 10-ft (3 m) 4-conductor shielded pigtail cable (replaces the quick-disconnect receptacle found on the base S702; does not include connector-mounted LEDs)
Features
- Targeted Near-IR Spectral Sensitivity: Employs a Germanium photodiode with a 950 nm to 1710 nm spectral response (half-intensity points) and a 1400 nm peak response optimized for luminous heavy oil and pulverized coal flames.
- 33 Hz High-Pass Flicker Discrimination: Integrated frequency filtering rejects steady-state infrared radiation emitted by glowing refractory brickwork, responding strictly to flame flicker above 33 Hz.
- Narrow 1-Degree Optical Sighting Cone: Tight 1° angle of view (1.45-inch / 3.7 cm target diameter at 6 feet / 1.8 m) allows accurate single-burner flame targeting on multi-burner boiler fronts without cross-reading adjacent flames.
- Solid-State Electronic Self-Check: Operates via processor-driven electronic check pulses with zero mechanical shutters, eliminating wear-prone moving parts under continuous marine and industrial duty.
- Factory-Sealed Pigtail Termination: Pre-wired 10-foot (3 m) C330S 4-conductor shielded cable with drain wire eliminates multi-pin connector corrosion and pin-backout in high-moisture, high-vibration environments.
Honeywell S702PF Technical Specifications
| Parameter | Technical Value |
|---|---|
| Brand / Manufacturer | Honeywell Process Solutions (Iris Series) |
| Manufacturer Part Number (MPN) | S702PF |
| Sensor Type | Germanium Photodiode (Infrared / Flicker) |
| Spectral Response Range | 950 nm to 1710 nm (1/2 intensity points); Peak at 1400 nm |
| High-Pass Flicker Filter | 33 Hz Standard |
| Optical Field of View | 1 Degree (1.45 in. diameter at 6 ft / 3.7 cm diameter at 1.8 m) |
| Input Voltage | 22 to 26 VDC (24 VDC nominal supplied by Signal Processor) |
| Cable Configuration | Factory-Installed 10 ft (3 m) C330S 4-Conductor Shielded Pigtail with Drain |
| Wiring Color Code | Red: +24VDC (VH +V) | White: Flame Signal (VH SIG) | Black: Self-Check (VH SC) | Green: Ground (VH GND) | Shield: Chassis GND |
| Housing Material & Size | Machined Aluminum Barrel; 1.48 in. (36 mm) Diameter x 9.4 in. (230 mm) Length |
| Lens Pressure Rating | 50 psi (3.45 bar) Maximum |
| Ambient Operating Temperature | -40°F to +185°F (-40°C to +85°C) Standard | -40°F to +149°F (-40°C to +65°C) Hazardous Locations |
| Environmental Protection | NEMA 4X / IP64 (when installed with UV-shielded conduit) |
| Compatible Signal Processors | Honeywell 700ACSP, 700DCSP, P531, P532 (P532AC / P532DC) |
| Hazardous & Safety Approvals | SIL 3 Fit for Use, FM, CSA Class I Div 2 Groups A-D T4A, IECEx Ex nA IIC T4/T5 Gc, CE, Inmetro |
Compatible Honeywell Signal Processors
- Honeywell 700ACSP: Single-channel universal AC signal processor (85–265 VAC, 50/60 Hz, 24 VDC battery backup)
- Honeywell 700DCSP: Single-channel DC signal processor (22–26 VDC primary, 24 VDC battery backup)
- Honeywell P531 & P532 Series (P532AC / P532DC): Multi-channel fail-safe signal processors capable of monitoring up to three viewing heads simultaneously
Compatible Mounting & Thermal Accessories
- 700DA: 1/2″ FNPT Delrin thermal/electrical insulating mounting adapter (S70X series)
- 700DA-1: 1″ FNPT Delrin thermal/electrical insulating mounting adapter (S70X series)
- 700UA: 1/2″ FNPT Ultem high-temperature heat insulator with 1/4″ purge air port
- 700ACC: S70X aluminum cooling canister (requires vortex cooler for extreme radiant heat zones)
- 700LTA: 3/8″ liquid-tight conduit cable adapter
Part Number Cross-References
- Honeywell S702: Identical Germanium IR sensor and 33 Hz filter, but uses a quick-disconnect plug receptacle (requires separate ASY782/ASY785 cable with diagnostic LEDs) instead of a fixed pigtail.
- Honeywell S702HF / S702HFPF: High-frequency IR variant featuring a 155 Hz high-pass filter instead of 33 Hz, used where extreme background flicker discrimination is required.
- Honeywell S802: Compact 1.14-inch (29 mm) stainless steel barrel IR viewing head with twist-lock mount (90 psi lens rating) for tight burner registers.
- Legacy Iris Systems Cross-Reference: Originally engineered under the Iris Systems S700 Series (Model S702PF) prior to Honeywell’s acquisition of Iris Flame Monitoring.
Applications
- Multi-Burner Industrial Steam Boilers: Boilers with a minimum 3-foot (1-meter) vertical and horizontal burner separation where a tight 1° viewing angle prevents cross-sighting.
- Refinery Fired Heaters & Reformers: Continuous flame monitoring on crude heaters, cracking furnaces, and steam methane reformers.
- Pulverized Coal & Heavy Residual Oil Burners: Primary flame safeguard sensing where high soot/particulate opacity blocks UV radiation.
- Natural Draft & Duct Burners: High-temperature combustion chambers requiring high-pass flicker rejection against glowing refractory walls.
Frequently Asked Questions
What is the difference between the Honeywell S702 and the S702PF viewing head?
Both models share the exact same Germanium IR photodiode, 950–1710 nm spectral range, 33 Hz high-pass flicker filter, and 1.48-inch aluminum housing. The difference lies in the electrical termination: the S702 uses a quick-disconnect multi-pin connector receptacle (requiring a separate cable assembly with built-in diagnostic LEDs), whereas the S702PF comes with a factory-sealed 10-foot (3 m) shielded pigtail cable and no connector LEDs.
Can the Honeywell S702PF be used on natural gas or clean hydrogen burners?
No. The S702PF is tuned specifically for near-infrared radiation (950–1710 nm) emitted by luminous heavy fuel oil, residual oil, and coal flames. Clean natural gas and hydrogen flames emit primarily ultraviolet (UV) radiation with minimal near-IR flicker, requiring a UVTron viewing head such as the Honeywell S706 or S706PF.
Which flame signal processors work with the Honeywell S702PF?
The S702PF is directly compatible with single-channel Honeywell 700ACSP (85–265 VAC) and 700DCSP (22–26 VDC) signal processors, as well as multi-channel Honeywell P531 and P532 (P532AC / P532DC) three-channel flame monitoring processors.
Why is electrical isolation required when mounting the S702PF on a boiler front?
The S702PF aluminum housing must be electrically isolated from the steel boiler casing using a Delrin (700DA) or Ultem (700UA) mounting adapter. Ground potential differences across marine engine room hulls or industrial boiler steelwork can introduce circulating currents into the signal ground, causing false flame drop-outs or self-check faults.
How does the S702PF perform self-checking without a mechanical shutter?
Instead of a motorized shutter blade that blocks the optical path, the Honeywell Series 700/800 processors send periodic electronic self-check pulses over the black (VH SC) conductor to test the Germanium photodiode and internal amplifier circuitry continuously during burner operation.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.

