Honeywell Enraf S0947601 Rev.10 SmartView Display 2558964-2
Condition: New – Open Box
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Honeywell Enraf S0947601 Rev.10 (2558964-2) SmartView Display Unit
The Honeywell Enraf S0947601 Rev.10 (Internal Assembly / Part Number: 2558964-2) is a dedicated, intrinsically safe graphic display and operator interface designed for local and remote tank-side inventory monitoring. Engineered for severe marine cargo, refinery, and bulk liquid terminal applications, this SmartView module interfaces directly with Honeywell Enraf tank gauging systems—including the SmartRadar FlexLine series and SmartServo 954 level gauges.
The display communicates natively via an intrinsically safe communication loop with internal FlexConn bus modules, providing operators and marine cargo engineers immediate visual verification of innage, ullage, product interface, average multi-element temperature, and diagnostic alarm statuses compliant with Weights & Measures (W&M) and API custody transfer standards.
Model Details
- Manufacturer: Honeywell Enraf (Delft, Netherlands)
- Model Designation: SmartView Display Assembly / Indicator Board
- Manufacturer Part Number (MPN): S0947601
- Hardware Revision: Rev. 10
- Sub-Assembly / Drawing Number: 2558964-2
- Display Technology: Monochromatic Graphic FSTN LCD, 64 × 128 dots
- Operating Topology: Gauge-mounted internal display or standalone 4-wire remote tank-side indicator
Technical Specifications
| Parameter | Engineering Specification |
|---|---|
| Manufacturer / Line | Honeywell Enraf / SmartView Series |
| Part Numbers | S0947601 (Rev.10) / PCB: 2558964-2 |
| Display Architecture | Monochrome Graphic LCD, 64 x 128 dot matrix, transflective with backlighting |
| Operating Voltage (IS Supply) | Nominal 12 V DC (Supplied via intrinsically safe gauge bus / FlexConn card) |
| Intrinsically Safe Entity Parameters | Ui ≤ 15 V DC; Ii ≤ 200 mA; Pi ≤ 1.2 W; Ci ≈ 0 μF; Li ≈ 0 mH |
| Field Cabling Requirements | 4-wire shielded twisted pair (Power +, Power -, Comms A, Comms B) |
| Maximum Loop Impedance | Single Display: Rmax = 8.5 Ω; Dual Remote Display: Rmax = 4.7 Ω |
| Permissible Line Capacitance / Inductance | Cmax ≤ 3.0 μF; Lmax ≤ 0.48 mH |
| Terminal Allocations | Pin 1: +12V DC (IS Power) | Pin 2: 0V GND | Pin 3: Data Line A | Pin 4: Data Line B | SHLD: Chassis Ground |
| Operating Temperature Range | -25 °C to +65 °C (-13 °F to +149 °F) |
| Storage Temperature Range | -50 °C to +75 °C (-58 °F to +167 °F) |
| Ingress Protection Rating | IP66 / IP67 (when housed in standard Honeywell Enraf die-cast aluminum enclosure) |
| Hazardous Area Classification | ATEX / IECEx: Ex ia IIB T4 Ga; FM / CSA: Class I, Div 1, Groups C, D T4 |
| Legal Metrology Standards | OIML R85; API MPMS Chapter 3.1A / 3.1B; ISO 4266 |
Key Features
- Intrinsically Safe Ex ia Topology: Rated for direct deployment in Class I, Division 1, Zone 0/Zone 1 hazardous environments without requiring explosion-proof enclosures or flamepaths for the local interface.
- High-Resolution Liquid Crystal Readout: 64 × 128 pixel dot-matrix graphic display capable of rendering alphanumeric tank variables, bar graphs, and dynamic diagnostic annunciators.
- Dual Mounting Flexibility: Operates both as an integral faceplate display inside the gauge’s FlexConn compartment or as a standalone, ground-level remote tank indicator connected over a shielded cable loop.
- Non-Intrusive Local Operation: Enables ground-level personnel to view tank parameters, review active process alerts, and perform routine configuration verification safely.
- Custody Transfer Grade Accuracy: Fully compliant with OIML R85 and API Chapter 3.1B visualization guidelines when linked to certified Enraf radar and servo level transmitters.
Compatibility
- Honeywell Enraf SmartRadar FlexLine Series: Models 990, 991, 992 (Free Space, Stilling Well, and High-Pressure Radar gauges)
- Honeywell Enraf SmartServo Gauges: SmartServo 954 Series (Internal slot mounting or Standalone remote connection option “B”)
- FlexConn Architecture: Directly connects to FlexConn I.S. bus and power supply modules
- Enraf Tank Inventory Software: Compatible with systems reporting through Entis Pro, Entis Tank Inventory System, and CIU 888 Communication Interface Units
Frequently Asked Questions
Can the Honeywell Enraf S0947601 Rev.10 replace older revisions such as Rev.06 or Rev.08?
Yes. The S0947601 Rev.10 (PCB 2558964-2) maintains backwards form, fit, and functional pin compatibility with earlier revisions installed in SmartRadar FlexLine and SmartServo 954 gauges. It mounts into the standard display slot and accepts the identical 4-wire terminal bus.
What is the maximum distance the SmartView can be mounted away from the gauge?
When installed as a remote, ground-level indicator, the maximum cable distance depends on cable loop resistance and capacitance. For a single display, total loop resistance must remain under 8.5 Ohms with capacitance below 3.0 µF. Using standard 16 AWG or 18 AWG twisted shielded instrumentation cable, operational distances up to 100 meters (328 feet) are routinely maintained.
Why is the SmartView display blank while the primary radar/servo gauge is operational?
A completely blank display usually indicates that the intrinsically safe power feed is interrupted, the terminal ribbon connection has worked loose, or line voltage has dropped below operating threshold. Verify the input voltage across Pins 1 and 2 (must be ~12 V DC) and inspect the cable polarity. If power is within tolerance and polarity is correct, verify that the display entity is assigned and enabled in the gauge’s configuration using Honeywell Engauge software.
Does this display require hot-work permits to open and inspect in hazardous areas?
The SmartView module and its host terminal interface are intrinsically safe (Ex ia). However, safety protocol requires adhering to regional and company permit procedures before opening any terminal housing within a Zone 0, Zone 1, or Class I, Div 1 envelope. If the host gauge houses non-intrinsically safe main power supply compartments on the same deck, standard cold-work/hot-work authorizations apply.
Can two SmartView displays be operated simultaneously from the same gauge?
Yes. Honeywell Enraf FlexLine systems support dual SmartView installations—one mounted internally on the gauge head and one mounted remotely at the bottom of the tank. When running dual displays, maximum permissible loop resistance drops to 4.7 Ohms to preserve voltage integrity across both units.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.

