The Eaton Durant 57601-402 is a multi-function electronic counter/control engineered for demanding marine automation, plant floor batching, and high-integrity process measurement. Operating on a 115 VAC (50/60 Hz) primary supply, the unit integrates three distinct counting registers: an 8-digit cumulative totalizer, a 6-digit single-preset main counter, and a 6-digit single-preset batch counter, accompanied by an independent event-time ratemeter.
Built within a compact 68 x 68 mm DIN housing sealed to NEMA 4 / IP65 on the front bezel, the 57601-402 delivers deterministic accuracy in harsh, electrically noisy environments. Featuring an integrated RS-485 half-duplex multi-drop communications interface, depluggable screw-clamp terminal blocks, scalable count/rate mathematics, and versatile transistor/relay outputs, this instrument excels in fuel consumption tracking, shaft RPM monitoring, cut-to-length machinery, and cargo transfer systems.
Model Details
- Manufacturer: Eaton Corporation
- Product Line: Ambassador Series Count Control
- Model Number: 57601-402
- Part Number / MPN: 57601402
- Configuration: 8-Digit Totalizer / 6-Digit Single Preset Counter / 6-Digit Batch Counter / Ratemeter
- Display Type: 2-line x 16-character backlit alphanumeric LCD
- Serial Interface: RS-485 Half-Duplex (Addressable 01–99)
Technical Specifications
| Parameter | Engineering Specification |
|---|---|
| Supply Voltage | 115 VAC (+10% / -15%), 50/60 Hz; approx. 10 VA power consumption |
| Display | Two-line, 16-character dot-matrix backlit LCD (Green standard); 0.30 in (7.6 mm) character height |
| Totalizer Capacity | 8 Digits (0 to 99,999,999) with non-volatile memory retention |
| Main / Batch Counters | 6 Digits each (0 to 999,999); 1 Main Preset level + 1 Batch Preset level; 2 ms coincidence check |
| Ratemeter Method | 1/tau (event-time measurement); 0.1 Hz to 10 kHz; updates in user-defined engineering units |
| Count Inputs (Inputs A & B) | Sinking (NPN) or Sourcing (PNP), magnetic pickup compatible; Low < 1.0 VDC, High > 3.0 VDC (Max 30 VDC); 9 count modes including Quadrature (x1, x2, x4), Add/Subtract, and Separate Up/Down |
| Max Count Frequency | High-speed: up to 10 kHz; Low-speed filtered: up to 200 Hz (contact debounce) |
| Control Inputs (1 to 4) | 4 configurable sinking/contact-closure inputs (Reset Main, Reset Batch, Reset Total, Program Lock, Output Control, Stop Count) |
| Sensor Power Supply | Regulated +12 VDC (±5%), 100 mA short-circuit protected DC output for external encoders/transducers |
| Relay Output | One SPDT (Form C) mechanical contact; Rated 5A at 120/240 VAC or 30 VDC resistive |
| Transistor Outputs | Two NPN open-collector transistors (Transistor 1 & Transistor 2); 30 VDC max, 100 mA sink per output |
| Output Operation Modes | Latched, timed pulse (0.01 to 99.99 seconds), or normal/reverse polarity logic |
| Scaler Ranges | Count Scaler: 0.00001 to 9.99999; Rate Scaler: 0.00001 to 99,999 (programmable floating decimal point) |
| Serial Interface | RS-485 half-duplex differential, 2-wire; Baud rates: 300 to 9600 bps; Selectable odd/even/no parity |
| Terminals & Wiring | Two-piece depluggable industrial screw terminal blocks (10-pin and 12-pin assignments) |
| Enclosure / Cutout | 68 x 68 mm DIN front panel; 65 x 65 mm panel cutout; Depth behind panel: 125 mm (4.92 in) |
| Front Panel Protection | NEMA 4 / IP65 water-tight and dust-tight when mounted with supplied elastomeric perimeter gasket |
| Operating Temperature | 0°C to +50°C (32°F to 122°F); Storage: -20°C to +70°C (-4°F to 158°F) |
| Relative Humidity | 0% to 90% non-condensing |
Features
- Tri-Register Architecture: Integrates an 8-digit cumulative totalizer with dual 6-digit registers (Main Count and Batch Count) to support simultaneous batch control, piece counting, and master volume accounting.
- Industrial Output Matrix: Furnishes one heavy-duty SPDT form-C mechanical relay and two high-speed NPN open-collector transistor outputs configurable for latched, pulsed (0.01 to 99.99 s), or reverse logic.
- Network Integration via RS-485: Embedded multi-drop serial communications bus allows remote setup, real-time register extraction, and automated SCADA/PLC handshaking over long transmission lines.
- Rugged Front Panel Sealing: NEMA 4 / IP65 front face with an 8-key tactile membrane prevents washdown moisture, lubricating oils, and saline ingress into electrical compartments.
Compatibility
- Rotary Pulse Generators & Incremental Encoders: Compatible with BEI Sensors, Dynapar, Dynapar Series 60, EPC (Encoder Products Company), Heidenhain, and Omron 5V to 24V differential/push-pull/open-collector quadrature encoders.
- Proximity Switches & Photoelectric Transducers: Directly compatible with all 2-wire and 3-wire DC NPN or PNP proximity sensors (Turck, Pepperl+Fuchs, Balluff, Sick, IFM Efector).
- Marine Flowmeters & Positive Displacement Meters: Pairs directly with positive displacement flowmeters (e.g., Oval, Emerson Micro Motion pulse transmitters, Badger Meter, Liquid Controls) for fuel oil bunker measurement and ballast flow monitoring.
- Legacy Drop-In Replacements: Fits legacy cutout cutouts for older Durant Ambassador, Durant President Series (e.g., 5881-series, 5882-series), and Kessler-Ellis Products (KEP) multi-function units.
Frequently Asked Questions
What is the primary difference between Eaton Durant 57601-402 and 57601-400?
The Durant 57601-400 is strictly a totalizer and rate indicator with basic transistor outputs. The 57601-402 includes the 8-digit totalizer and ratemeter, but adds a 6-digit single-preset main counter, a 6-digit batch counter, and a 5A SPDT output relay, allowing for active machine batching and process cutoff operations.
Does the Eaton Durant 57601-402 require a battery backup to retain counts during a blackout?
No. The 57601-402 incorporates internal non-volatile EEPROM memory. In the event of an engine room blackout or mains supply disconnection, all accumulated totalizer values, batch counts, preset levels, and configuration parameters are preserved indefinitely.
How do I configure the totalizer scale factor for custom engineering units?
Using the front-panel membrane keypad, navigate to the PROGRAM: SCALERS menu. The count scale factor can be programmed between 0.00001 and 9.99999, and the floating decimal point can be positioned anywhere across the display. This converts incoming pulses directly into standard engineering readouts such as Liters, Gallons, Cubic Meters, Millimeters, or Feet.
What is the panel cutout dimension required for mounting?
The Eaton Durant Ambassador series adheres to the standard 68 x 68 mm DIN bezel specification. The physical panel cutout required is 65 mm x 65 mm (2.56 x 2.56 inches), with a clear depth behind the mounting surface of at least 125 mm (4.92 inches) to accommodate depluggable field wiring plugs.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.