GE 3Sc-RS Phased Array Ultrasound Probe
Condition: New
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
The GE 3Sc-RS is a wideband, sector phased-array ultrasound transducer designed for deep-cavity hemodynamic assessment, cardiac evaluations, abdominal screening, and transcranial Doppler analysis. Engineered with high-efficiency acoustic impedance matching and piezoelectric crystal arrays, the 3Sc-RS operates over a broad nominal bandwidth of 1.3 MHz to 4.0 MHz.
Configured with GE’s proprietary zero-insertion-force RS connector (paddle-style multi-pin terminal), this probe interfaces across GE console lines—including the Vivid, LOGIQ, Voluson, Versana, and Venue series. Beyond hospital cardiology units, the 3Sc-RS is widely deployed in point-of-care ultrasound (POCUS) configurations aboard maritime research vessels, naval hospital ships, offshore platform medical bays, and heavy commercial fleet infirmaries where compact, high-reliability diagnostic instruments are required under harsh vibration and variable thermal conditions.
Model Details
- Model Name / Code: 3Sc-RS
- OEM Manufacturer: GE HealthCare
- Primary GE Manufacturing Part Number (MPN): 5863286
- Equivalent & Legacy Cross-Reference Part Numbers:
- 5433833
- 5433833-R
- 47237516
- P00940P1
Features
- Wideband Sector Phased Array: Operates from 1.3 MHz to 4.0 MHz, balancing shallow near-field resolution with deep acoustic penetration down to 30 cm.
- Ultra-Compact Acoustic Footprint: A 18.4 mm × 23.7 mm lens profile allows acoustic windowing through tight adult and pediatric intercostal spaces.
- High-Density RS Connector: Gold-plated, spring-loaded multi-pin RS interface delivers micro-volt signal integrity and high signal-to-noise ratio (SNR).
- Multi-Modality Doppler Architecture: Fully supports 2D B-Mode, Harmonic Imaging, Color Doppler (CFM), Pulsed Wave (PW) Doppler, Continuous Wave (CW) Doppler, and M-Mode.
- Environmental & Chemical Durability: IPX7-rated acoustic head immersion sealed against glutaraldehyde, hydrogen peroxide vapor, and enzymatic medical sanitizers.
Technical Specifications
| Specification Parameter | Engineering Rating / Technical Value |
|---|---|
| Transducer Architecture | Sector Phased Array (Piezoelectric PZT Array with Acoustic Backing) |
| Bandwidth Frequency Range | 1.3 MHz – 4.0 MHz (Operating Center Frequency ~2.5 MHz) |
| Acoustic Lens / Footprint Size | 18.4 mm × 23.7 mm |
| Maximum Field of View (FOV) | 90° – 120° Sector Scan Angle (system-configuration dependent) |
| Acoustic Depth of Field (DoF) | Up to 300 mm (30 cm) penetration |
| Interface Connector / Terminal Type | GE RS-Style (Compact Zero-Insertion-Force Multi-Pin PCB Connector) |
| Biopsy Guide Compatibility | Multi-angle needle guide bracket adaptable (optional accessory) |
| Cable Assembly & Strain Relief | Reinforced coaxial micro-bundle cable (~2.0 m length) with molded bend-limiters |
| Supported Operating Modes | 2D Fundamental, Tissue Harmonic Imaging (THI), Color Flow (CFM), PW, CW, M-Mode, TVI |
| Ingress Protection Rating | IPX7 (Acoustic head to strain-relief immersion line per IEC 60529) |
| Operating Temperature & Humidity | +10°C to +40°C (+50°F to +104°F); 30% to 85% RH non-condensing |
| Storage & Transit Limits | -20°C to +60°C (-4°F to +140°F); atmospheric pressure 700 hPa to 1060 hPa |
Frequently Asked Questions
What is the primary difference between the 3Sc-RS and the older 3S-RS probe?
The 3Sc-RS represents GE’s single-crystal-inspired acoustic architecture upgrade over the legacy 3S-RS. It provides broader acoustic bandwidth, improved penetration in high-BMI patients, enhanced signal-to-noise ratio, and noticeably cleaner endocardial border delineation in difficult echocardiographic windows.
Can I plug the GE 3Sc-RS into a console with standard rectangular D-connectors?
No. The 3Sc-RS features a compact, flat multi-pin RS connector designed for portable and mid-range GE consoles. Systems utilizing full-sized rectangular “D-connectors” (such as the high-end Vivid E9 or LOGIQ E9) require an active RS-to-D mechanical port adapter, or the native D-series probe equivalent (e.g., M5S-D).
How do I verify if my GE Vivid or LOGIQ software version supports this probe?
Most modern LOGIQ and Vivid series running system software revision R2 or later support the 3Sc-RS natively. Navigate to your system’s Utility > System Diagnostics > System Info page to verify installed software options and transducer software keys.
What are the symptoms of acoustic lens delamination?
Delamination occurs when the protective front-face rubber membrane separates from the internal matching layer. Visible signs include air bubbles under the lens face, peeling around the perimeter seams, or acoustic shadow lines along the near-field image sector. If delamination is present, discontinue use immediately to prevent gel ingress into the piezo array and avoid electrical leakage risks.
What test documentation accompanies reconditioned probes?
Every reconditioned GE 3Sc-RS unit is accompanied by a certified bench test report detailing channel capacitance, electrical safety/leakage current measurements in compliance with IEC 60601-1, and an acoustic phantom profile confirming beam symmetry and penetration depth.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.