Deep Sea Electronics DSE7420 MKII AMF Generator Controller
Condition: Used
Country of Origin: United Kingdom
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Deep Sea Electronics DSE7420 MKII Engine Generator Controller AMF Panel
The Deep Sea Electronics DSE7420 MKII is an Auto Mains (Utility) Failure (AMF) control module engineered specifically for single-set diesel and gaseous generating systems operating in mission-critical, marine, prime-power, and critical standby configurations. Featuring a 32-bit dual-core processor core architecture, the DSE7420 MKII monitors utility mains supply across three phases and executes automated transfer switching, engine crank cycles, frequency/voltage regulation, and comprehensive fault trips.
This controller is equipped with integrated CAN (J1939-75), magnetic pickup (MPU), and alternator sensing inputs alongside onboard USB, RS232, RS485, and Ethernet (TCP/IP, SNMP, Modbus) interfaces. Its ruggedized injection-molded enclosure and frontal polyurethane gasket deliver IP65 protection against airborne moisture, hydrocarbon aerosols, and industrial vibration.
Model Details
- Manufacturer: Deep Sea Electronics (United Kingdom)
- Base Model: DSE7420 MKII Auto Mains Failure Control Module
- Standard Variant MPN: 07420-03 (Standard LCD Display, -30 °C to +70 °C operating range)
- Heated Display Variant MPN: 07420-04 (Built-in Display Heating Element, -40 °C to +70 °C operating range for sub-zero installations)
- Associated Software Tool: DSE Configuration Suite PC Software (License-free)
Technical Specifications
| Parameter | Operational Range / Rating | Engineering Notes / Standards |
|---|---|---|
| DC Operating Voltage | 8.0 V to 35.0 V DC Continuous | 5.0 V support for up to 60 seconds; survives 0 V crank dropouts for 100 ms |
| Current Consumption | 510 mA @ 12 V, 240 mA @ 24 V (Max operating) | Standby draw: 330 mA @ 12 V, 160 mA @ 24 V |
| AC Sensing Voltage | 15 V to 415 V AC (L-N) / 26 V to 719 V AC (L-L) | True RMS measurement; Class 1 accuracy; 3-phase 4-wire, 3-phase 3-wire, single-phase |
| AC Frequency Sensing | 3.5 Hz to 75.0 Hz | Resolution: 0.1 Hz; Accuracy: ±0.2 Hz |
| CT Secondary Ratings | 1 A or 5 A secondary rated currents | Burden: 0.5 VA per phase; 5 A isolation transformer required for UL compliance |
| Fuel & Crank Relay Outputs | 15 A DC at battery plant supply voltage | Protected against inductive back-EMF; internal high-current copper traces |
| Auxiliary Transistor Outputs | 2 A DC maximum per output (Terminals 6-11) | Solid-state DC switching to positive rail |
| Breaker Switching Relays | 8 A @ 250 V AC Volt-Free (Outputs C & D) | Dry contact outputs suitable for shunt trips, UV coils, or ATS control coils |
| Digital Input Triggering | Negative Switching (Contact closure to 0 V DC) | Optically isolated inputs with software debounce filter (20 ms to 1000 ms) |
| Analog Input Resolution | 10-bit analog-to-digital converter (ADC) | Configurable channels for resistive sender curves (0-3000 Ω), 4-20 mA, or 0-10 V |
| Magnetic Pickup Input | ±0.5 V to 70 V Peak, 10,000 Hz Maximum | Impedance: 10 kΩ; sensitivity adjustable for low cranking speeds |
| Dimensions & Cut-Out | Overall: 245 x 184 x 51 mm | Cut-out: 220 x 160 mm | Maximum panel thickness: 8.0 mm; Module weight: 0.88 kg (1.94 lbs) |
Features
- 3-Phase Mains & Generator Sensing: Continuous True RMS monitoring across L1-N, L2-N, L3-N (15 V to 415 V AC) and L1-L2, L2-L3, L3-L1 (26 V to 719 V AC) with under/over voltage, frequency, phase rotation, and unbalanced load trips.
- Configurable Power Protection: Full kW, kvar, kVA, and power factor (pf) metering with integrated reverse power, overcurrent, overload, and restricted/unrestricted earth-fault detection.
- Simultaneous Multi-Port Communications: Native independent ports for USB 2.0, RS232, RS485, and Ethernet 10/100 Mbit (supporting simultaneous Modbus RTU/TCP and SNMP v2c).
- Flexible I/O & Sensor Support: 8 negative-switching digital inputs, 6 analog inputs (configurable for 0–10 V, 4–20 mA, 0–3 kΩ resistive curves, or digital), 2 volt-free 8 A changeover relays, and 6 DC auxiliary outputs.
- Built-in PLC Logic & Data Logging: Onboard graphical PLC ladder editor with up to 20 internal instrumentation logging channels written to non-volatile flash memory.
Applications
- Marine Auxiliary & Emergency Gensets: Harbor generators, emergency switchboards, vessel blackout recovery systems, and unclassed auxiliary power units.
- Critical Standby Infrastructure: Data centers, hospital life-support power systems, municipal water/wastewater pump stations, and banking facilities requiring rapid utility-to-generator auto transfer.
- Prime & Remote Power Stations: Continuous baseline power plants in mining, oil and gas skids, telecom tower off-grid microgrids, and construction distribution units.
- Dual-Mutual Standby Applications: Master/Slave alternating dual-generator configurations utilizing inter-module RS232/RS485 data links to equalize operational run hours.
Compatibility
- Electronic Engine Protocol (CANbus / J1939):
- Caterpillar / Perkins: ADEM III, ADEM IV, ADEM A4, Perkins ECM (1104D, 1106D, 1300 Series EDI, 2000/4000 series).
- Cummins: Quantum Series (QSB, QSC, QSL, QSK19, QSK38, QSK50, QSK60 via CM570, CM850, CM2150, CM2250).
- Volvo Penta: EDC4, EMS2, and D13/D16 Tier 4 Final / Stage V installations.
- MTU / DDC: ADEC (DDEC engines), ECU7, ECU8, and SAM modules.
- Scania: EMS S6, S7, S8 with SCR / DPF soot-load level readouts.
- Deutz: EMR2, EMR3, EMR4.
- Mechanical Engines: Fully compatible using traditional senders (VDO, Datcon, Murphy, PT100, 4–20 mA transmitters) along with flywheel magnetic pickups (MPU) or alternator stator tap (W-terminal) sensing.
- DSENet Peripheral Expansion:
- DSE2130: Input Expansion Module (adds up to 8 inputs: 4 digital, 4 analog).
- DSE2157: Output Relay Expansion Module (adds 8 configurable 2 A DC relays).
- DSE2548: LED Annunciator Panel (16-channel remote visual alert system).
- DSE2510 / DSE2520: Remote Display Units operating over the RS485 communication link.
Part Number Cross-References
- DSE Direct Reference: 7420-03, 7420-04, 7420-003-01, 7420-004-01
- Predecessor Generation: DSE7420 MK1 (07420-01, 07420-02) — Direct mechanical drop-in replacement; requires software logic file migration via DSE Configuration Suite.
- Equivalent Functionality Lineage: DSE7320 MKII (Mid-tier variant with reduced I/O channels and no native dual-mutual standby architecture).
- OEM Custom Assemblies: SDMO 31613822101, FG Wilson 10000-51421, Olympian 10000-05393.
Frequently Asked Questions
What distinguishes the DSE7420 MKII from the DSE7410 MKII?
The DSE7410 MKII is strictly an Auto Start control module designed for standalone generator operation without direct mains switching logic. The DSE7420 MKII includes dedicated utility/mains AC sensing circuits (Terminals 41–44) and internal automatic mains failure (AMF) logic, allowing it to control two separate circuit breakers or contactors to autonomously switch load between the mains grid and the standby generator.
Can the DSE7420 MKII be installed as a direct drop-in replacement for the original DSE7420 MKI?
Yes. Both generations share identical front fascia cut-out dimensions (220 mm x 160 mm) and panel mounting profiles. While pin assignments for major power, mains sensing, and digital I/O lines are fundamentally interchangeable, the internal processor architecture differs. You must open the existing MK1 configuration file within the free DSE Configuration Suite software, export/convert it into the MKII schema, and flash it to the new module via the USB Type-B port prior to plant commissioning.
How do I configure the 6 analog inputs if using custom marine transducers?
Within the DSE Configuration Suite PC software, navigate to Inputs > Analogue Inputs. Each of the channels (A through F) can be configured independently as a 0–10 V input, a 4–20 mA current loop, or a 0–3000 Ω variable resistive input. If standard sender profiles (e.g., VDO, Veglia, Murphy) do not match your sensor, you can manually construct a custom 10-point interpolation curve matching raw electrical signal values against specific engineering units (Bar, PSI, °C, °F, Liters).
Does the DSE7420 MKII provide built-in synchronization or load-sharing across multiple generators?
No. The DSE7420 MKII provides AMF control for a single generator running against a mains utility supply. For applications demanding multi-generator paralleling, active load sharing, and automatic peak-lopping synchronization, the DSE8610 MKII (multi-set synchronizer) or DSE8620 MKII (single generator with mains paralleling/synchronizing) should be specified.
Why does the controller fail to detect engine speed when cranking with an MPU?
MPU speed detection requires a minimum peak-to-peak voltage threshold during cranking. Ensure the gap between the magnetic pickup sensor tip and the flywheel gear tooth crest is set correctly (typically 0.5 mm to 0.75 mm, achieved by screwing the sensor in until it touches the tooth and backing off 1/2 to 3/4 turn). During cranking at low RPM, the MPU must generate at least 1.0 V AC RMS across Terminals 29 and 30 for the DSE internal counter circuits to register rotation and disengage the starter motor.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.