Schneider Electric 007300152 TAC Xenta 302 Programmable Controller
Condition: New with Box
Country of Origin: Sweden
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Schneider Electric 007300152 Controller TAC Xenta 302
The Schneider Electric 007300152 is the complete TAC Xenta 302 standalone programmable unitary controller, designed for direct digital control (DDC) of medium-complexity HVAC, auxiliary machinery, and process loops. Built on a two-piece modular architecture, the controller separates the removable electronics processor unit from the fixed field-wiring terminal base. This design lets watchkeeping engineers replace or swap the logic module without disconnecting field sensor cables or actuator wiring.
Operating on 24 V AC or 19–40 V DC, the TAC Xenta 302 executes custom functional block logic programmed via TAC Menta and communicates across an Echelon LONWORKS TP/FT-10 free-topology network at 78 kbps. When network links drop, the controller maintains autonomous closed-loop regulation using its onboard microprocessor and battery-backed real-time clock.
Model Details
- Primary Manufacturer Part Number (MPN): 007300152 (Complete TAC Xenta 302 Standalone Assembly)
- Model Series: TAC Xenta 300 Series (TAC Xenta 302 / TAC Xenta 302/N/P)
- Hardware / Firmware Revisions Seen in Field: HW 2.3, V3.88 (and V3.x series)
- Country of Origin: Sweden
- Condition Available: New Surplus (Original Box)
Technical Specifications — Schneider Electric 007300152 (TAC Xenta 302)
| Specification Category | Technical Parameter |
|---|---|
| Manufacturer | Schneider Electric (TAC) |
| Part Number (MPN) | 007300152 (Electronics: 0-073-0011-2 / Base: 0-073-0901) |
| Model Name | TAC Xenta 302 Standalone Programmable Controller |
| Supply Voltage | 24 V AC ±20% (50/60 Hz) or 19–40 V DC |
| Power Consumption / Sizing | Max. 5 W (10 VA transformer sizing) |
| Digital Inputs (X1–X4) | 4 channels; 33 V DC open contact; 4 mA closed contact; min. 20 ms pulse |
| Thermistor Inputs (B1–B4) | 4 channels; TAC 1800 Ω at 25 °C NTC (-50 °C to +150 °C) |
| Universal Inputs (U1–U4) | 4 channels; Digital (26 V DC / 4 mA), Thermistor (1800 Ω), or 0–10 V DC (100 kΩ) |
| Digital Relay Outputs (K1–K4) | 4 potential-free relays; max. 230/250 V AC, 2 A resistive (10 A max. external fuse) |
| Analog Outputs (Y1–Y4) | 4 channels; 0–10 V DC; 12-bit D/A; max. 2 mA short-circuit proof; ±1% accuracy |
| Fieldbus Communication | Echelon LONWORKS TP/FT-10 Free Topology, 78 kbps (Terminals C1, C2) |
| Service & HMI Ports | Modular jack for TAC Xenta OP panel; RS-232 jack for TAC Menta PC tool |
| Real-Time Clock & Backup | ±12 min/year at +25 °C; 72-hour power failure memory retention |
| Ambient Operating Temp | 0 °C to +50 °C (+32 °F to +122 °F) |
| Protection & Enclosure | IP20, ABS/PC thermoplastic housing |
| Dimensions & Weight | 180 × 110 × 75 mm (7.1 × 4.3 × 3.0 in.) / 1.0 kg (2.2 lbs) |
| Certifications | CE (EN 61010-1, EN 50081-1, EN 50082-1), UL 3111-1, CSA C22.2, LonMark Certified |
Part Number Cross-References
- Complete Assembly (Electronics + Terminal Base): 007300152 / 0-073-0015-2
- Electronics Module Only (TAC Xenta 302/N/P): 0-073-0011 / 0-073-0011-2 / 007300112
- Terminal Base Part Only (TAC Xenta 300/3000): 0-073-0901 / 00730901
- Standalone OP/B Variant: 0-073-0089-2
Features
- Balanced 20-Point Onboard I/O: Combines 12 inputs (4 digital, 4 thermistor, 4 universal) and 8 outputs (4 electromechanical relays, 4 analog 0–10 V DC) for single-unit control of air handlers, chillers, or heat exchangers.
- Hot-Swappable Two-Piece Construction: All field terminations land on the separate terminal base (0-073-0901), allowing rapid electronics replacement during critical port calls or plant shutdowns without disturbing wiring harnesses.
- Native LONWORKS TP/FT-10 Networking: Communicates at 78 kbps using Standard Network Variable Types (SNVTs) and explicit LONTALK messaging for peer-to-peer data exchange and SCADA integration.
- 72-Hour Power Failure Protection: Integrated real-time clock (±12 minutes/year accuracy at +25 °C) and memory backup retain schedules, setpoints, and trend logs during main switchboard blackouts.
- Transient-Protected Field Inputs: Every input channel complies with EN 50082-1 electromagnetic immunity standards to prevent false trips caused by heavy contactor switching and VFD noise.
Compatibility
- Engineering & Programming Software: TAC Menta (graphical functional block programming and XIF generation) and TAC Vista IV / Engineering Classic / LNS Network management tools.
- Local Operator Interfaces: Compatible with the TAC Xenta OP operator panel, which snaps directly onto the front housing, mounts on a control cabinet door, or connects via modular cable as a handheld service terminal.
- I/O Expansion Modules: Supports up to 2 remote TAC Xenta 400 series I/O modules (such as TAC Xenta 411, 412, 421A, 422A, 451A, 452A) over the LONWORKS TP/FT-10 bus when field point counts exceed 20 I/O.
- Field Sensors & Actuators: Direct compatibility with Schneider Electric / TAC 1.8 kΩ NTC thermistors, 0–10 V DC pressure/humidity transmitters, 0–10 V DC modulating damper/valve actuators, and 24–230 V AC pilot relays.
Frequently Asked Questions
What is the difference between part number 007300152 and 0-073-0011-2?
Part number 007300152 is the complete factory assembly consisting of both the removable TAC Xenta 302 electronics module and the screw-terminal connection base. Part number 0-073-0011-2 (or 0-073-0011) refers strictly to the upper electronics processor unit (TAC Xenta 302/N/P), which snaps onto an existing 0-073-0901 terminal base.
Can the Schneider Electric TAC Xenta 302 run on 24 V DC shipboard or panel power?
Yes. The controller accepts either 24 V AC ±20% (50/60 Hz) or 19–40 V DC across terminals G and G0. Keep in mind that if you use 24 V DC supply power, any external field actuators or sensors sharing that supply must also be rated for DC operation.
Does the TAC Xenta 302 come pre-programmed out of the box?
No. The TAC Xenta 302 is a freely programmable controller rather than a fixed-function thermostat. Before installation, an engineer must upload the custom functional block application using TAC Menta software via the front RS-232 modular port or download it over the LONWORKS network via TAC Vista.
How many expansion I/O modules can be connected to a single TAC Xenta 302?
You can expand a single TAC Xenta 302 with up to 2 remote TAC Xenta 400 series I/O modules over the LONWORKS TP/FT-10 twisted-pair network. Each expansion module is bound exclusively to one host controller.
What temperature sensors are compatible with the B1–B4 and U1–U4 inputs?
The analog thermistor inputs are engineered for TAC 1800 Ω (1.8 kΩ) at 25 °C NTC thermistor sensors, covering a measurement range of -50 °C to +150 °C (-58 °F to +302 °F). If you need to integrate 4–20 mA transmitters, connect an external 500 Ω precision shunt resistor across a 0–10 V DC configured Universal Input (U1–U4) and M.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products