Honeywell CC-PAOH01 51405039-176 HART Analog Output Module

Condition: New

Live Support
  • 100% SECURED PAYMENTS
  • AVAILABLE IN STOCK - READY TO SHIP
  • EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
  • HASSLE FREE 14-DAY RETURNS
NDMARINETECH PAYMENT OPTIONS
Description

Honeywell CC-PAOH01 HART Analog Output Module (Part Number: 51405039-176)

The Honeywell CC-PAOH01 (Manufacturing Part Number: 51405039-176) is a 16-channel High-Level Analog Output Module engineered for Honeywell’s Experion® Process Knowledge System (PKS) Series C I/O architecture. Built for mission-critical industrial process plants, offshore installations, and marine propulsion/ballast automation, the CC-PAOH01 generates precise 4–20 mA current loops to drive final control elements such as electro-pneumatic control valve positioners, variable frequency drive (VFD) setpoint inputs, and marine thruster controllers.

Every channel integrates an independent Highway Addressable Remote Transducer (HART) modem, enabling simultaneous two-way digital communication overlaying the standard 4–20 mA analog control line without loop disturbance. This provides field instrument asset management, online configuration, dynamic parameter polling, and predictive health diagnostics directly from the Experion DCS engineering console. The CC-PAOH01 installs directly onto a paired Series C Input/Output Termination Assembly (IOTA), utilizing an angled, module-locking design that optimizes enclosure airflow, protects against marine engine-room vibrations, and supports full online hot-swapping under powered conditions.

 

Model Details

  • Model Number: CC-PAOH01
  • Spare Part Number / MPN: 51405039-176
  • Module Description: Series C 16-Channel High-Level HART Analog Output Module (AO 16pt HART)
  • Associated Base Assembly / Bare Board: 51405038-xxx series / 51305xxx circuit references
  • Non-HART Equivalent Cross-Reference: CC-PAOX01 (51405039-175) / CC-PAON01
  • Conformal Coated Marine/Harsh Environment Identifiers: CC-PAOH01 is delivered standard with conformal coating compliant with ISA G3 Harsh environmental exposure standards.
  • Country of Origin: United States / Global Assembly
  • Harmonized Tariff / HS Code: 8537.10.1190 / 8538.90.0000

 

Technical Specifications

Parameter / Functional Metric Engineering Rating / Operational Limit
Number of Channels 16 High-Level Analog Output Channels (Single-Ended, Isolated Group)
Output Signal Range Standard: 4.0 mA to 20.0 mA; Settable Range: 0.0 mA, 2.9 mA to 21.1 mA
Digital Communication Protocol HART Protocol (FSK Bell 202 overlay, Rev 5, 6, & 7 compatible)
D/A Converter Resolution 16-bit D/A conversion (±0.05% of Full Scale resolution)
Calibrated Accuracy @ 25°C ±0.35% of Full Scale (including linearity and offset)
Output Current Linearity ±0.05% of Full Scale nominal
Output Temperature Drift ±0.005% of Full Scale / °C
Internal Output Readback Accuracy ±4.0% of Full Scale
Maximum Loop Resistive Load 800 Ω across full supply range (22.0 VDC to 28.0 VDC)
Compliant Loop Voltage 16.0 VDC minimum compliant voltage across field load
Maximum Open Circuit Voltage 22.0 VDC
Settling / Response Time Settles within 1.0% of final target value within ≤ 80 ms (DAC input code to terminal)
Redundancy Switchover Transfer Gap ≤ 10 ms maximum zero-current gap during module-to-module mastership switchover
Output Ripple < 100 mV peak-to-peak across 250 Ω load at power line frequency
Nominal Power Supply Requirements 24.0 VDC (Operational range: 22.0 VDC to 28.5 VDC via Series C Power Distribution)
Power Dissipation 7.0 W nominal (up to 11.2 W worst-case at 20 mA full load all channels)
Operating Temperature Range 0°C to +60°C (+32°F to +140°F) continuous
Storage / Transit Temperature -40°C to +85°C (-40°F to +185°F)
Operating Relative Humidity 5% to 95% Non-condensing
Module Dimensions (H x W x D) 145 mm x 165 mm x 60 mm (5.71 in x 6.50 in x 2.36 in)
Net Module Weight Approx. 0.40 kg (0.88 lbs)

 

Controller & Software Compatibility

  • Experion Process Knowledge System (PKS): Fully compatible with Release R300, R310, R400, R410, R430, R500, R510, R520, and upward.
  • Execution Controllers: Honeywell Series C C300 Controller, C300-CNI (ControlNet Interface), and FIM4/FIM8 Field Interface Modules.
  • Cabinet Integration: Standard 19-inch mounting channels within Series C standard unshielded and shielded industrial enclosures.

 

Field Terminal Allocations

  • Channel 01: Terminal AO01(+) / AO01(-)
  • Channel 02: Terminal AO02(+) / AO02(-)
  • Channel 03: Terminal AO03(+) / AO03(-)
  • Channel 16: Terminal AO16(+) / AO16(-)
  • Chassis / Shield: Grounding bar directly bonded to the cabinet PE ground bar via the IOTA low-impedance ground lug.

 

Applications

  • Marine Main Propulsion & Gas Turbine Control: Modulating fuel metering valves, governor actuator inputs, and variable-pitch propeller hydraulic servo units on commercial vessels, tankers, and LNG carriers.
  • Offshore FPSO & Drilling Platforms: Remote ESD and choke valve positioning, flare gas flow controls, and ballast pump VFD frequency setpoint management.
  • Petrochemical & Refining Refining Units: Modulating flow control loops for hydrocrackers, catalytic reformers, distillation reboiler valves, and compressor anti-surge control.
  • Power Generation Facilities: Boiler feedwater control valves, steam bypass controls, flue gas damper actuators, and deaerator pressure control loops.
  • Boiler Management & Burner Management Systems (BMS): Fuel-to-air ratio actuators, heavy fuel oil (HFO) preheating valve positioning, and soot blower control.

 

Frequently Asked Questions

What is the primary difference between Honeywell CC-PAOH01 and CC-PAOX01?

The Honeywell CC-PAOH01 features full, integrated HART communication capability with onboard modems for every channel. The CC-PAOX01 is an analog-only output module that drives standard 4–20 mA loops but cannot transmit or decode HART digital instrument telemetry.

Can I hot-swap the CC-PAOH01 module while the Experion DCS is running?

Yes. The Honeywell Series C platform is designed with Removal and Insertion Under Power (RIUP) capabilities. You can safely remove and replace the CC-PAOH01 module from its IOTA without powering down the carrier rack or disturbing other operational modules on the link.

How does the CC-PAOH01 handle open-wire field fault conditions?

When field wiring is cut or an actuator disconnection occurs, the module’s integrated current readback circuitry detects that loop current cannot flow. It immediately reports a Channel Soft Failure alarm back to the C300 controller and Experion alarms console, allowing maintenance crews to address line continuity before equipment trip.

What is the maximum distance and wire gauge recommended for CC-PAOH01 field loops?

For reliable HART communication and 4–20 mA signal transmission, run shielded twisted pair cable (typically 16 AWG to 18 AWG / 1.0 mm² to 1.5 mm²). At 18 AWG, field cable runs can comfortably extend up to 1,500 meters (5,000 feet) as long as total loop resistance does not exceed 800 ohms.

Can the CC-PAOH01 be installed on both redundant and non-redundant assemblies?

Yes. For single non-redundant loops, the module mounts on the 6-inch CC-TAOX01 or conformal-coated CC-GAOX21 IOTA. For critical dual-redundant loops, two CC-PAOH01 modules plug side-by-side into the 12-inch CC-TAOX11 or CC-GAOX11 IOTA to deliver seamless switchover protection.

Shipping and Delivery

14 DAYS RETURN POLICY

RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.

NOTE:

IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.

FEEDBACK

WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWING TRUST IN US.

100% Genuine Products

-> YOU WILL GET WHAT YOU SEE IN PHOTOS

-> UNDERSTAND THE PRODUCT BEFORE BUYING

PACKAGING

QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.

SHIPPING

FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.

TAXES & IMPORT DUTIES

DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.