Qualitrol 118P-120-K-0-2 Temperature Monitor
$999.00 Original price was: $999.00.$789.00Current price is: $789.00.
Condition: Used
1 in stock
- 100% SECURED PAYMENTS
- AVAILABLE IN STOCK - READY TO SHIP
- EXPRESS DELIVERY: WORLDWIDE DELIVERY BY FEDEX & DHL EXPRESS COURIER
- HASSLE FREE 14-DAY RETURNS
Qualitrol 118P-120-K-0-2 Electronic Temperature Monitor for Dry-Type Transformers
The Qualitrol 118P-120-K-0-2 is a microprocessor-based Intelligent Transformer Monitor (ITM) engineered specifically to protect dry-type distribution, propulsion, and auxiliary step-down transformers. In demanding environments—such as commercial marine engine rooms, offshore drilling rigs, and heavy utility substations—unmonitored core and winding heat soak causes catastrophic insulation dielectric breakdown.
The 118P-120-K-0-2 resolves this by continuously reading up to three independent Type K (Chromel-Alumel) thermocouples embedded directly into the low-voltage and high-voltage phase coils. The monitor executes precise multistage cooling fan automation, progressive thermal alarm warnings, and emergency breaker trip actuation. Equipped with a high-contrast front-panel digital LED display and diagnostic indicator lamps, the unit delivers instantaneous thermal visibility while retaining the highest recorded phase temperature for post-trip forensic analysis.
Model Details
- Manufacturer: Qualitrol Company LLC
- Product Series: 118 / 118P / 118 ITM Series
- Model Number: 118P-120-K-0-2
- Manufacturer Part Number (MPN): 118P120K02
- Internal / Assembly Reference: TMDS243313
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Primary Power Supply | 120 VAC nominal (±15%), 50/60 Hz; universal chassis accepts 80–300 VAC / 48–280 VDC |
| Power Consumption | < 10 Watts continuous burden |
| Sensor Inputs | 3 Channels, Type K (NiCr-NiAl) Thermocouples, grounded or ungrounded |
| Measurement Range | 0°C to +250°C (32°F to 482°F) |
| Measurement Accuracy | ±1% of full scale span across operating temperature limits |
| Digital Display | High-visibility 7-segment 3-digit LED readout for real-time temperature, channel ID, and setpoint audit |
| Status Indicators | Discrete LEDs for Channel 1, Channel 2, Channel 3, Max Temp, Fan Active, Pre-Alarm, Trip, and Fault |
| Relay Contacts – Fan Control | SPST Form A, heavy-duty contact rating (10A @ 120/240 VAC resistive, inductive motor load rated), internal fuse protection |
| Relay Contacts – Alarm & Trip | SPDT Form C contacts rated 10A @ 120/240 VAC, 0.5A @ 125 VDC resistive |
| Relay Operational Modes | Failsafe (normally energized alarm loop) and Non-Failsafe field-configurable states |
| Internal Audible Alarm | 85 dB piezo buzzer at 30 cm; silencer push-button located on front fascia |
| Terminal Allocations | Heavy-duty industrial screw barrier strip terminals (accepts 12 to 22 AWG stranded or solid copper wire) |
| Analog / SCADA Retransmission | Selectable loop current output (4–20 mA, 0–1 mA, 0–20 mA proportional to maximum phase temperature) |
| Communication Protocol | Optional 2-wire isolated RS-485 Modbus RTU / RS-232 serial diagnostic bus |
| Operating Ambient Temperature | -20°C to +70°C (-4°F to 158°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Ambient Humidity | 0 to 95% Relative Humidity, non-condensing |
| Mounting Configuration | Panel cutout flush mount with rear locking brackets; standard switchboard enclosure profile |
| Housing Construction | Corrosion-resistant powder-coated industrial steel casing with gasketed aluminum front bezel |
| Net Weight | Approx. 3.57 lbs (1.62 kg) |
Key Features
- Three-Phase Thermal Scanning: Dedicated acquisition for three Type K thermocouples continuously calculates and displays individual winding hot-spot profiles and stores absolute peak operating values.
- Multistage Relay Actuation: Heavy-duty electromechanical dry contacts configured for automatic forced-air fan control, high-temperature pre-alarms, and failsafe high-high emergency trip signaling.
- Automated Fan Exerciser: Built-in programmable timing cycle periodically rotates cooling fans during extended low-load periods, preventing motor bearing freeze, grease gumming, and dust buildup.
- Sensor Diagnostics & Open-Circuit Detection: Built-in burnout protection triggers a non-trip alarm and front-panel open circuit indicator (“—“) if a thermocouple lead severs or drifts, avoiding false transformer tripping.
- Rugged Steel Flush Mount Architecture: Industrial vibration-resistant enclosure with heavy-gauge terminal strips engineered to withstand harsh high-EMF, marine switchboard, and switchgear installations.
Equipment Compatibility
- Switchgear & Transformer Manufacturers: Square D / Schneider Electric (Sorgel series), ABB / Hitachi Energy, Siemens (GEAFOL and 3AH/ADVAC switchgear line), Eaton / Cutler-Hammer, Hammond Power Solutions (HPS), and Federal Pacific.
- Marine & Offshore Power Plants: Main Propulsion step-down transformers, bow thruster step-up units, 440V distribution skids, and emergency switchboard enclosures.
- Industrial Drive Isolation: Variable Frequency Drive (VFD) 6-pulse, 12-pulse, and 24-pulse dry-type isolation transformers.
Applications
- Marine Vessel Machinery Spaces: Continuous thermal oversight of propulsion step-down transformers, vessel service transformer banks, and deck winch power skids exposed to severe engine room ambient heat.
- Offshore Oil & Gas Platforms: Topside hazard-mitigated electrical rooms where continuous fan automation is vital to keep switchgear rooms pressurized and cool.
- Commercial & Utility Substations: Indoor cast-resin and vacuum pressure impregnated (VPI) transformers in hospitals, data centers, high-rise buildings, and underground metro tunnels.
- Renewable Power Installations: Inverter-duty step-up transformers in wind turbine nacelles/towers and commercial solar field distribution hubs.
Frequently Asked Questions
What does error code “—” mean on the Qualitrol 118P digital display?
The “—” readout indicates an open-circuit sensor fault. The monitor has detected a severed wire, missing thermocouple, or damaged probe on that specific channel. The alarm relay triggers to notify technicians, but the trip relay remains inactive to prevent accidental power outages.
Can the Qualitrol 118P-120-K-0-2 accept RTD sensors like PT100?
No. The “K” in the model designation indicates that the internal analog-to-digital converter board and terminal cold-junction block are factory-hardware calibrated exclusively for Type K thermocouples. For 100-ohm platinum RTDs, a dedicated Qualitrol 118 unit calibrated for RTD inputs must be specified.
What is the difference between 118P-120-K-0-2 and 118P-120-K-4-2?
The numerical suffix specifies relay configuration and hardware I/O options. The “0-2” variant features standard dry contact arrangements (Fan, Alarm, Trip), whereas “4-2” configurations often include extra auxiliary form-C contacts (Relay 4 and Relay 5) or dedicated remote SCADA output loops.
How do I test the fan and alarm relays without taking the transformer offline?
The unit features an integrated front-panel test button routine. Pressing and holding the test interface cycles the LED segments, audits internal setpoint thresholds, triggers the audible beeper, and allows controlled verification of output relay contacts without applying real physical heat to the transformer winding sensors.
What power supply can be wired to the primary input terminals?
The 118P-120-K-0-2 uses a nominal 120 VAC auxiliary line, but incorporates an internal universal power supply stage capable of safely handling operational fluctuations between 80 to 300 VAC (50/60 Hz) or 48 to 280 VDC.
14 DAYS RETURN POLICY
RETURNS ARE ACCEPTED IN 14 DAYS. BUYER PAYS THE SHIPPING CHARGES. RESTOCKING FEES 20%.
NOTE:
IF THE ITEM COMES UNDER CUSTOMS, THE BUYER WILL BE FULLY RESPONSIBLE FOR DUTIES AND OTHER CHARGES. WE, AS THE SELLER, DO NOT ACCEPT RETURNS OR REFUNDS IN THIS CASE. KINDLY CONNECT WITH US BEFORE PURCHASING AN ITEM OR IF YOU HAVE ANY OTHER QUERIES.
FEEDBACK
WE WILL BE WAITING FOR YOUR VALUABLE FEEDBACKS. THANK YOU FOR SHOWINGÂ TRUSTÂ INÂ US.
100% Genuine Products
-> YOU WILL GET WHAT YOU SEE IN PHOTOS
-> UNDERSTAND THE PRODUCT BEFORE BUYING
PACKAGING
QUALITY PACKING FOR EACH PRODUCT. ASSURED SAFE & UNDAMAGED DELIVERY.
SHIPPING
FeDEX, DHL EXPRESS INTERNATIONAL SHIPPING.
TAXES & IMPORT DUTIES
DESTINATION COUNTRY ALL TAXES & DUTY TO BE PAID BY BUYER (NOT INCLUDED IN PRICE.

